f � , _ __ _ ' — - f"-_—_ -- _ -- �, <br /> f - , _ _ � <br /> . i � . — — <br /> WOOD IN CONTACTNRTH CONCRETE/EXTERIOR IXPOSURE <br /> TRUSS NOTES SHALLBETREATEDWfTH_PRESERVATNESPERAQA/AWPA GENERAL CONSTRUCTION NOTES <br /> ' I STRFSS ANALYSIS AN�DRAW[NGS/DETAiLS SHALL BE S7AMPED 8Y AN and BEAR THE AWPB MARK � N a <br /> ' USE w'nh PRESSURE PTRENTED WOODS <br /> APPROVED STATE of WASHINGTON REGISTERED ENGINEER ALL WORK MUST COMPLY WITH ALL CURRENTLY ACCEPTED CODES. � � <br /> � DRAVJINGS/DETAllS SHAIL BE ON-SCfE FOR FRAMING INSPECTOR _ NEW PRESSURE-TREATED WOOD LS MGHLY CORROSNE.ALL BOLTS, 2012 INTERNATIONAL BUILDING CODE 12 IBC <br /> PRE-MANUFACiURED TRUSSES SHALL BE IDENTIFIED BY MANUFACTURED'S STAMP. NAILIIVG,HANGERS,fASTENERS W CONTACT WITH PT LUMBER MUST. � � ° <br /> I' USE APPROVED/APPLICABLE TRUSS SUPPORT HANGERS. BE A M[N OF: TRIPLE ZINC Z-MAX(G185 per ASTEM A653) ; 2012 WTERNATIONAL RESTDENTIAL CODE 12 IRC W ��„ <br /> � F TRUSSES SHALL BE 50 FRAMED AN�INTO THE FRAMEWORK SO AS TO HOT DID GALVAN]ZED(ASTM A123 for CONNEGTORS) AND ALL OTHER APPISCABLE MECHAMCAL/SAFETY CODES. A W� I <br /> ALL ROO <br /> , ' F4RM AN MTEGRAL PART OF THE WHOIF BUILDING, ROOF TRUSSES SHALL (A S T M 1 5 3 f o r F A S T E N E R S,A N C H O R S) � � <br /> � HAVE 10iN7S WELL-F1TiED AND SHALL HAVE ALL TENSION MEMBERS L ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE REQUII2EMENTS <br /> WELL TIGHTENED BEFORE ANY LOAD IS PLACED UPON THE TRUSS. Of THE DRAV1(INGS,SPECIFICATION$AND NOTES. `� � <br /> i q <br /> DtAGONAL AND SWAY BRAQNG SHALL BE USED. DESIGN CRITERIA: 2, DIMENSIONS ARE TO FACE-0E-FRAMING. DO NOT SCALE DRAWINGS. FIELD �� <br /> � ENGINEEWNG DATA AND DEfA�S SHALL BE APPROVED BY THE BUIIDING OFF[QAL CONTRUCTION TYPE VB ' VERIFY BEFORE CONSTUCTION or ORDERING SPEQFIt MATERIALS. .d� <br /> BEFORE ANY FIELD CUT OR TRUSS ALTERATiON. OCCUPANCY: R3 3. VERIFY EMSTING CONDInONS,GRADES AND DIMENStONS AT THE SIfE LOCATION �� <br /> FIELD IDENTIF[CATION OF LIGHT METAL PLATE-CONNECTED TRUSSES IS REQIJIRED. SQSMIC DESIGN D2 , OF BUIIDING ON PROPERTY LIES W1TH THE OWNER/COMRACTOR BUILDING �� <br /> INFORMAT[ON BRANDED,MARKED OR OTHERWLSE PERMANENTLY AFFDCED WIND SPEED 85 MPH pERMlMETER AND FIOOR ELEVATIONS SHALL BE EXTABLLSHED. BUILDING SET- <br /> TO EACH TRUSS SHALL CONTAU�THE FOLLOVMING: EXPOSURE B �. <br /> IDENTIFICATION Of TRUSS MfGR Co. SNOW LOAD 25 psf BACKS AND HQGHT RESTRIClIONS COMPLTANCE SHALL BE VERIFIED BY <br /> THE DESIGN LOAD � FROST LINE DEPTH IS INCHcS CONTRACTOR. <br /> THE TRUSS SPAQNG. , ASSUMED BEARWG 4. IICENSED SURVEYOR SHALL VERIFY IXCAVATIONS/HQGHTS IF FINLSHED _ _ <br /> , - - SOIL• Z00�Pst DIMENSIONS ARE WITFQN 24 INCHES OF LOCAL LIMTfS,PRIOR TO FINAL ASSEMBLY: <br /> , �n7 NEW FouNDATor�s) 5. A COMPETENT EXPERIENCED MECHANQAL ENQNEER,LICENSED CONTRACTOR OR � <br /> �' . -- • PLUMBER SHALL DESIGN THE PLUMBING,HEATING,VENTILATION,SPRINKLER AfVD � <br /> GRAV[IY LOADS: RESIDENTIAL AIR CONDTflONING SYSTEMS. PERMITS FOR ALL WORK. <br /> ROOP DEAD LOAD: 15 psf 6. FURNANCE&WATERHEATERS: INSTALL PER WSEC,IRC OR LOCAL CODES. � <br /> ROOf WE LOAD: 25 psf WHEN GAS APPLIANCES ARE LOCATED IN GARAGES ALL PILOTS,BURNERS AND <br /> FLOOR uVE LOAD 40 psf ' SWITCHES A MIN.OF 18 INCHES ABOVE FINISHED FLOOR and PROYIDED WITH A � <br /> FLOOR DEAD LOADS 12 psf SYSTEM FOR ADEQUATE CONBUSTION AIR SUCH APPL[ANCES IN GARAGES ARE <br /> BALCONY LNE LOAD: 60 psf � <br /> I PARTIRON LOADS: 10 psf TO BE PROTECTED FROM DAMAGE WITH BOLLARDS/BARRIERS. <br /> 7. DUCT ALL FANS,VENTS,DRAYER RANGE HOODS TO OUTSIDE INSULATE IN UN- <br /> I - ROOF SHEATHING: 15l321NCH DOC PS-1!�-2 HEATED SPACES. IRC 1502.3 �- --- <br /> I WSEC 2012 (APA Performance rate� 8. IQTCHEN VENT FANS OVER 400 CFM TO BE PROVIDED W1TH MAKE-UP AT � <br /> � Wazhington State Energ�Code v� O�L . Strud-i-floor 24 in o.c ratin w/EXP 1 lue � , - <br /> ' e��yC�� ,� g 9 APPROXIMATELY THE,SAME IXHAUST�AIR(2ATE M1503.4 <br /> Marine Zone 4 SUB-FLOOR SHEATHING: 3/a WCH DOC PS-1 � , o <br /> (APA Performance ratecq 9. WHERE REQUIRED ROOF/FOOTING DRAINS SHALL BE TIGHTIINED SEPARATELY <br /> WINDOWS(VERTICAL) 30 ' TO APPROVED DISPOSA� SfORM DRA[NAGE CONTROL SHALL MEET THE � <br /> SKYI.IGHTS .50 St'rud-I-floor 24 in oc Rating w/IXP 1 glue. <br /> - REQUIREMENTS OF THE ENGINEERING DEPARTMENT SfANDARD PLAN FOR THE � <br /> j CEILING �-'19 WALL STRUCRIRAL PANEIS: 32lI6 INDIX RATING )�R]$ICf(ON GOVERNING THE CONSTRUCTION SITE. � <br /> ; " WOOD FRAMED WALL R-21 5 PLY w/EXP 1 GLUE V <br /> (Standard framing of 16 inches o.c. 10.PROVIDE FURRINGS,PS REQUIRED,TO CONCEAL MECHANICAL AND ELECTRICAL <br /> Refer to SHEAR WALL SCHEDULE FOR � <br /> Headets with miv.ofR-10) WORK IN ALL FINLSHED AREAS.OBSERVE CODES FOR FlIRE BLOCI4NG,INSULATION� <br /> I g�,ppR R-30 THICKNESS. <br /> I BELOW GRADE WALL 10/ISl21 INT+'CB # CONNECTORS/FASTENERS: per IBC FOR 1URISDICIION. <br /> i SLAB FLOOR 10,2 ft'�'� 1L VERIFY TYPE,MANUFACfURER AND LOC11TION OF ALL PLUMBING FDCTURES, � <br /> SIMPSON STRONG-TIE fasteners <br /> Recommended. FAUCETS,DOORS,WINDOWS,CABINETS,HARDWAR�LIGHIING FD(TURES,AND � <br /> I <br /> � . R-10 contmuous insulation on eMerior of wall,or R-IS on the CONCRETE Compression strength @ 28 days,psi APPUANCES WCfH OWNER PRIOR TO PURCHASE OR INSTALLATIO . <br /> � continuous insularion on the interioc of wall,or R-21 cavity insulation Slab-on-grade:3000psi Qnterior/exterior) 12. IN SEATlIE PROVIDE DEAD BOLT CATCH OR APPROVED LOCIQNG DEVICE PER ( w <br /> � plus Thetmal Break betwcen slab and basement wall at the interior V � <br /> � ofthebasementwall Basementwall 2500 psi 5'h sack SEATTLE BUILDING CODE <br /> � • "10/15/ll+TB"shail be pccmitted to be met with R-13 cavity insulation Footings 2500 psi 5�fi sack 13. OBSERVAT[ON VISITS TO THE SITE BY DE4GNER AND/OR REPRESEMATNES SHALL � <br /> ; on the interior of the basement wall plus R-5 continuous insu(atioa on tha Cont footings 2500 psi 5 3h sack <br /> interior/e�eriorofthewall. NOT BE CONSTUED AS INSPECIION NOR APPROVAL OR CONSTRUCTION. o <br /> • '�IN13"meaas R-10 continuous iosulation on the interior or e��ior of 14. ALL WORKERS ON SIfE SHALL BE KNOWN TO CONTRACTOR AND THEIR SAFETY A <br /> � I the home or R-13 insulation at the inurior of the basement walL ' FIRST PRIORITY. � _ <br /> . "TB"means thermai tireelc between floor slab and basement wall. ' � <br /> r WOOD MEMBERS: 15. WHEN IN DOUBT.......ASKI� - _ <br /> �'-�- <br /> •� R-10 continuous insulaUon req.undu heated slab on grade floors. STUDS/PIATES_ _ HE S?'lJD , -- <br /> - . JOISTS/RAFTERS bc8-2x12 HF�2 <br /> __ _ -- • - BEAMS/HEADERS 4x6-4 x12 Hf�l . J <br /> POSTS 4x DF#i WHENEVER POSSIBLE USE - <br /> � 6x OF#1 2012 IBC , AMERtCAN MADE PRODUCfS <br /> IN YOUR CONSfRUCT10N PROIECT. <br /> � TOP FIBER BOTT RBER 2012 IRC KEEP OUR FELLQW GTIZENS WORKING. <br /> ' GLB 24F-V4 u00 Psi 2400 Psi 2012 IMC LIST OFAMERICAN MANUFACTURERS , <br /> � ' ��. '�'G�G- GLB 24F-H8 2400 psi 2400 psi AVAItABLE ON REQUEST. ' �. <br /> R'13 k21 p5� 2900 psi 2900 psi <br /> 2012 IFC FIRE CODE <br /> , R.ZI 2012 WSEC � <br /> R 5 —�..tp �� ¢io �0 _ Q•io " <br /> ' FULL NG�T .. FUuI NG"C FU(Lt. H�,j REBAR perASTM A615 2011 NAT ELEC CODE <br /> Q_�o Q�' Q �b 64 or 1E55 GRAOE 40 WA STATE AMENDMENTS W <br /> ��� 1 - R�y� � �, 2�1''i INTEP�I D�RIr,�ID 1k5 or GREATER GRADE 40 _ � <br /> - ..� . — t Q-lo Ex _ � 1 <br /> I _, - Z.R�13 f�at{+R52i4�D UNLfSSOTHERWfSENOTED 'UNO' I t <br /> i` I � Rlo Exj. f <br /> 1 I _ ,� <br /> IIII ��l.oW Ca2D�D� INSULA'[ION D?TtotiJs <br /> I 1oIZ �v�c K�l02.,2•8 � � ''/ZO�'� _ _ ` <br /> I I <br />