Simple Heating System Size: Washington State
<br /> This heatinq svstem sizinq calculator is based on the Prescriptive Requirements of the 2012 Washington State Enerqv Code(WSEC)and ACCA
<br /> Manuals J and S.This calculator will calculate heatina loads oniv.ACCA procedures for sizinq coolinq svstems should be used to determine coolinp
<br /> loads.
<br /> The glazing(window)and door portion of this calculator assumes the installed giazing and door products have an area weighted average U-factor of
<br /> 0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2012 WSEC.
<br /> Please fiil out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section,
<br /> some values will be calculated for you. If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension
<br /> Program at(360)956-2042 for assistance.
<br /> Project Information Confact lnformation
<br /> Parcel tt:006445000Q2300 Keith Sitzmann
<br /> GOZA MICHAEL E&CAROLYN HETHERWICK 425-466-4245
<br /> 4927 23RD AVE,EVERETT,WA 98203 keith@sun-spaces.com
<br /> Heatinq Svstem Tvpe: •an om�sYSce� OHeat Pump
<br /> To see detailed instructions for each section.plece your cursor on the word"Instructions".
<br /> DesiQn Temperature
<br /> '=',::f°�=<=-�,:'�'�: ,- _ Design Temperature Difference(�T) 47
<br /> IEverett 1C _ ___ � 47=Indoor(70 degrees)-Oufdoor Design Temp
<br /> Area of Buildinq
<br /> Conditioned Floor Area
<br /> � - Conditioned Floor Area(sq ft) 200
<br /> Average Ceiling Height Conditioned Volume
<br /> �'��'����^�-�'°1��`" Average Geiling Height(ft) 9.0 1,800
<br /> Glazinp and Doors U-Factor X Area = UA
<br /> ��,s>,,.�:r,.;.;:s
<br /> 0.30 124 37.29
<br /> Skvliphts U-Factar X Area = UA
<br /> _;s;;�.�,:,:;.�� 0.50 36 18.00
<br /> Insulation
<br /> Attic U-Factor X Area = UA
<br /> ���=�'�����+�'=T��+� No selection 0 ---
<br /> - �Seleci R-Value �
<br /> Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA
<br /> ;"`';t""'��Ot' j R 3a vented----- � 0.027 176 4.75
<br /> _ _ _,... ..__..... _,..._. . ..
<br /> Above Grade Walls�see Frnure+� U-Factor X Area UA
<br /> ����i�����<<t,o�,, - 0.056 289 16.17
<br /> R-2l Intermediate �
<br /> . . _.__,.___.,�. iw.�...,....,«...... ...,_.
<br /> Floors U-Factor X Area UA
<br /> �nstir„c±:;.;n< -- 0.029 124 3.60
<br /> R-30 �
<br /> �__------
<br /> _ _.� _ ._ .. . ...
<br /> Below Grade Walls�see Finu.e�i U-Factor X Area UA
<br /> ��� �;:':-���>t" — No selection 0 ---
<br /> ISelect R-value � �
<br /> `�---�--�----- -----..
<br /> .. ___. . ..........._.....,. .�..._..- .,._._ .>.,_..,.,
<br /> Slab Below Grade�see F�o�re�a F-Factor X Length UA
<br /> �{����;����::��,�� �— — No selection 0 ---
<br /> I Select mnditioning � �
<br /> ....... ... . ......_. . ._ . ...._ . ,_.... ,. . ...
<br /> Slab on Grade�see F;Dure u F-Factor X Length UA
<br /> ':�kr�,���•�.f's No selection 0 ---
<br /> � Seiect R-Value �
<br /> Location of Ducts
<br /> ��:�t`���`������� Duct Leakage Coefficient
<br /> I No Ducts _� ,
<br /> - 1.00
<br /> Sum of UA 79.81
<br /> Envelope Heat Load 3,751 Btu/Hour
<br /> Fiqure 1. sumoruaxnr
<br /> �,�,,,,, .....
<br /> Air Leakage Heat Load 914 Btu/Hour
<br /> a,,,_,,,,,._„,�,,;:",.�;�W Volume X 0.6 X nT X.018
<br /> A6weGrade � Building Design Heat Load 4,665 Btu/Hour
<br /> '�.� Air Leakage+Envelope Heat Loss
<br /> 1 S!
<br /> Building and Duct Heat Load 4,665 etu/Hour
<br /> Ducts in unconditioned space:Sum of Building Heat Loss X 1.10
<br /> Ducts in conditionetl space:Sum ol Building Heat Loss X 1
<br /> Maximum Heat Equipment Output 6,531 Btu/Hour
<br /> Building and Duct Heat Loss X 1.40 for Forced Air Fumace
<br /> Buifding and Duc[Heat Loss X 125 for Heat Pump
<br /> (07/01/13)