Simple Heating System Size: Washington State <br /> This heatinq svstem sizinq calculator is based on the Prescriptive Requirements of the 2012 Washington State Enerqv Code(WSEC)and ACCA <br /> Manuals J and S.This calculator will calculate heatina loads oniv.ACCA procedures for sizinq coolinq svstems should be used to determine coolinp <br /> loads. <br /> The glazing(window)and door portion of this calculator assumes the installed giazing and door products have an area weighted average U-factor of <br /> 0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2012 WSEC. <br /> Please fiil out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section, <br /> some values will be calculated for you. If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension <br /> Program at(360)956-2042 for assistance. <br /> Project Information Confact lnformation <br /> Parcel tt:006445000Q2300 Keith Sitzmann <br /> GOZA MICHAEL E&CAROLYN HETHERWICK 425-466-4245 <br /> 4927 23RD AVE,EVERETT,WA 98203 keith@sun-spaces.com <br /> Heatinq Svstem Tvpe: •an om�sYSce� OHeat Pump <br /> To see detailed instructions for each section.plece your cursor on the word"Instructions". <br /> DesiQn Temperature <br /> '=',::f°�=<=-�,:'�'�: ,- _ Design Temperature Difference(�T) 47 <br /> IEverett 1C _ ___ � 47=Indoor(70 degrees)-Oufdoor Design Temp <br /> Area of Buildinq <br /> Conditioned Floor Area <br /> � - Conditioned Floor Area(sq ft) 200 <br /> Average Ceiling Height Conditioned Volume <br /> �'��'����^�-�'°1��`" Average Geiling Height(ft) 9.0 1,800 <br /> Glazinp and Doors U-Factor X Area = UA <br /> ��,s>,,.�:r,.;.;:s <br /> 0.30 124 37.29 <br /> Skvliphts U-Factar X Area = UA <br /> _;s;;�.�,:,:;.�� 0.50 36 18.00 <br /> Insulation <br /> Attic U-Factor X Area = UA <br /> ���=�'�����+�'=T��+� No selection 0 --- <br /> - �Seleci R-Value � <br /> Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA <br /> ;"`';t""'��Ot' j R 3a vented----- � 0.027 176 4.75 <br /> _ _ _,... ..__..... _,..._. . .. <br /> Above Grade Walls�see Frnure+� U-Factor X Area UA <br /> ����i�����<<t,o�,, - 0.056 289 16.17 <br /> R-2l Intermediate � <br /> . . _.__,.___.,�. iw.�...,....,«...... ...,_. <br /> Floors U-Factor X Area UA <br /> �nstir„c±:;.;n< -- 0.029 124 3.60 <br /> R-30 � <br /> �__------ <br /> _ _.� _ ._ .. . ... <br /> Below Grade Walls�see Finu.e�i U-Factor X Area UA <br /> ��� �;:':-���>t" — No selection 0 --- <br /> ISelect R-value � � <br /> `�---�--�----- -----.. <br /> .. ___. . ..........._.....,. .�..._..- .,._._ .>.,_..,., <br /> Slab Below Grade�see F�o�re�a F-Factor X Length UA <br /> �{����;����::��,�� �— — No selection 0 --- <br /> I Select mnditioning � � <br /> ....... ... . ......_. . ._ . ...._ . ,_.... ,. . ... <br /> Slab on Grade�see F;Dure u F-Factor X Length UA <br /> ':�kr�,���•�.f's No selection 0 --- <br /> � Seiect R-Value � <br /> Location of Ducts <br /> ��:�t`���`������� Duct Leakage Coefficient <br /> I No Ducts _� , <br /> - 1.00 <br /> Sum of UA 79.81 <br /> Envelope Heat Load 3,751 Btu/Hour <br /> Fiqure 1. sumoruaxnr <br /> �,�,,,,, ..... <br /> Air Leakage Heat Load 914 Btu/Hour <br /> a,,,_,,,,,._„,�,,;:",.�;�W Volume X 0.6 X nT X.018 <br /> A6weGrade � Building Design Heat Load 4,665 Btu/Hour <br /> '�.� Air Leakage+Envelope Heat Loss <br /> 1 S! <br /> Building and Duct Heat Load 4,665 etu/Hour <br /> Ducts in unconditioned space:Sum of Building Heat Loss X 1.10 <br /> Ducts in conditionetl space:Sum ol Building Heat Loss X 1 <br /> Maximum Heat Equipment Output 6,531 Btu/Hour <br /> Building and Duct Heat Loss X 1.40 for Forced Air Fumace <br /> Buifding and Duc[Heat Loss X 125 for Heat Pump <br /> (07/01/13) <br />