My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 45-11 2018-09-20
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 45-11
>
3003 W CASINO RD BLDG 45-11 2018-09-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/20/2018 2:17:50 PM
Creation date
8/10/2017 8:44:57 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 45-11
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
69
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AIRCRAFT LOADING WALKWAYS 415-7 <br /> tem.Each 21,E in. (63.5 mm)hose connection shall be equipped tible or flammable liquids into a safely located,approved con- <br /> with a 21h in.x I 1 in. (63.5 mm x 38 mm)reducer and cap. tainment facility. <br /> 4.5.4.2 Class III standpipe systems shall be provided in non- 5.1.6 Grates and drain covers shall be removable to facilitate <br /> sprinklered buildings.The exceptions in NFPA 14,Standard for cleaning and flushing. <br /> the Installation of Standpipe and Hose Systems,for Class III systems <br /> shall be applicable to this requirement. 5.1.7*If open-grate drainage trenches are used as a collection <br /> means,such open trenches,including branches,shall not be <br /> 4.5.5 Water Supply. Water supply from public or private over 125 ft (38 m) in length with a minimum interval of 6 ft <br /> sources shall be adequate to supply maximum calculated (1.8 m)between open-trench sections to act as fire stops.Each <br /> sprinkler demand plus a minimum of 500 gpm (1893 L/min) 125 ft (38 m) section shall be individually drained through <br /> for hose streams. The supply shall be available at the rate underground piping.Open trenches shall not be used where <br /> specified for a period of at least 1 hour. they are in the line of pedestrian or passenger traffic. <br /> 4.5.5.1*Main sizes shall be hydraulically calculated based on 5.1.8 Underground piping and components used in drain- <br /> the total domestic and fire protection requirements. Mains age systems shall be noncombustible and inert to fuel. <br /> shall be not less than 8 in. (203 mm) in diameter except that <br /> laterals shall be permitted to be 6 in. (152 mm) in diameter if 5.2 Drain and Separator Maintenance. <br /> not over 200 ft (61 m) long. 5.2.1*Periodic maintenance checks shall be conducted of all <br /> 4.5.5.2* Hydrants shall be readily accessible to fire-fighting ramp drainage systems and interceptors to ensure that they <br /> vehicles traveling on surfaces adequate for supporting such are clear of obstructions and function properly. <br /> vehicles. <br /> 5.2.2 Large volume flushing with water shall be conducted <br /> 4.5.5.2.1 Hydrants shall be listed. through appropriate drainage elements to purge residual fuel <br /> 4.5.5.2.2 Hydrants shall be located or protected to prevent from these drainage elements after any large fuel spill on the <br /> mechanical or vehicular damage,including taxiing aircraft. aircraft fueling ramp enters the drainage system. <br /> 4.5.5.2.3 Hydrants recessed into the ground shall have iden- <br /> tifiers in the pavement to assist in their prompt location at <br /> night and by personnel who might not be familiar with the Chapter 6 Aircraft Loading Walkways <br /> location of the hydrants. <br /> 4.5.5.3*Water supply systems shall be regularly tested to en- 6.1 Basic Design. <br /> sure operation. 6.1.1* Each aircraft loading walkway installation shall be de- <br /> 4.5.6 Portable Fire Extinguishers. Portable fire extinguishers signed to provide a safe means of egress from the aircraft for a <br /> shall be provided throughout the airport terminal building in period of 5 minutes under fire exposure conditions equivalent <br /> accordance with NFPA 10,Standard for Portable Fire Extinguishers. to a free-burning jet fuel spill fire. <br /> 6.1.2 Protection of the aircraft loading walkway shall be ac- <br /> Chapter 5 Aircraft Fueling Ramp Drainage complished by one of the following methods: <br /> (1) Construction design meeting the requirements of Sec- <br /> 5.1 Aircraft Fueling Ramp Slope and Drain Design. tions 6.1 through 6.4 <br /> 5.1.1*Aircraft fueling ramps shall slope away from terminal (2) Fixed fire protection meeting the requirements of Sec- <br /> buildings,aircraft hangars,aircraft loading walkways,or other tions 6.1,6.2,and 6.5 <br /> structures,with a minimum grade of 1 percent(1:100)for the 6.2 Requirements for All Aircraft Loading Walkways. <br /> first 50 ft (15 m). Beyond this distance, the ramp slope to <br /> drainage inlets shall be permitted to be reduced to a mini- 6.2.1*Interior finish other than textiles of walls,ceilings,and <br /> mum of 0.5 percent(1:200). walkways shall be Class A as defined in 10.2.3.4(1) of NFPA <br /> 5.1.2*Aircraft fueling ramp drainage as specified herein shall 101, Life Safety Code, and classified in accordance with <br /> be accomplished by the provisions of 5.1.1 in conjunction with NFPA 255,Standard Method of Test of Surface Burning Characteyis- <br /> the following: tics of Building Materials. <br /> (1) The use of drain inlets with connected piping 6.2.2 Interior textile finish of walls and ceilings in walkways <br /> (2) The use of open-grate trenches shall be as limited by 10.2.4.1(5) of NFPA 101,Life Safely Code. <br /> 5.1.3 Drainage inlets,where provided,shall be located a mini- 6.2.3 Interior floor finish in walkways shall be Class I as defined <br /> mum of 50 ft(15 m)from structures outlined in 5.1.1. in 10.2.7.4(l)of NFPA 101,Life Safety Code,and classified in accor- <br /> dance with NFPA 253, Standard Method of Test for Critical Radiant <br /> 5.1.4 The drainage system of any aircraft fueling ramp shall be H.x ofFloor Covering Systems Using a Radiant Heat Energy Source. <br /> so designed that the fuel or its vapor cannot enter into the drain- <br /> age system of buildings,areas utilized for automobile parking, 6.2.4 There shall be no transparent or translucent walls,win- <br /> public or private streets,or the public side of airport terminal or dows, or surfaces other than those windows located in the <br /> aircraft hangar structures.In no case shall the design allow fuel to ramp access service door and in the cab area for the purpose <br /> collect on the aircraft fueling ramp or adjacent ground surfaces of operating the aircraft loading walkway. <br /> where it could constitute a fire hazard. 6.2.5* During a ramp fire emergency,walkway interiors shall <br /> 5.1.5 The final separator or interceptor for the entire airport have a positive air pressure delivered from a source that shall <br /> drainage system shall be designed to allow disposal of combus- remain uncontaminated. <br /> 2008 Edition <br />