415-16 AIRPORT TERMINAL BUILDINGS,FUELING RAMP DRAINAGE,AND LOADING WALKWAYS <br /> Table B.1 Fire Resistance Ratings(in hours) for Type I through Ttype V Construction <br /> Type I Type II Type III Type IV Type V <br /> 443 332 222 111 000 211 200 2HH 111 000 <br /> Exterior Bearing Walls <br /> Supporting more than one 4 3 2 1 0' 2 2 2 1 0' <br /> floor,columns,or other <br /> bearing walls <br /> Supporting one floor only 4 3 2 1 0' 2 2 2 1 0' <br /> Supporting a roof only 4 3 1 1 0' 2 2 2 1 0' <br /> Interior Bearing Walls <br /> Supporting more than one 4 3 2 1 0 1 0 2 1 0 <br /> floor,columns,or other <br /> bearing walls <br /> Supporting one floor only 3 2 2 1 0 1 0 1 1 0 <br /> Supporting roofs only 3 2 l 1 0 1 0 1 1 0 <br /> Columns <br /> Supporting more than one 4 3 2 1 0 1 0 H2 1 0 <br /> floor,columns,or other <br /> bearing walls <br /> Supporting one floor only 3 2 2 1 0 1 0 H2 1 0 <br /> Supporting roofs only 3 2 1 1 0 1- 0 H2 1 0 <br /> Beams,Girders,Trusses,and <br /> Arches <br /> Supporting more than one 4 3 2 1 0 1 0 I-I2 1 0 <br /> floor,columns,or other <br /> bearing walls <br /> Supporting one floor only 3 2 2 1 0 1 0 H2 1 0 <br /> Supporting roofs only 3 2 1 1 0 1 0 1-12 1 0 <br /> Floor Construction 3 2 2 1 0 1 0 H2 1 0 <br /> Roof Construction 2 1'/2 1 1 01 0 H2 1 0 <br /> Exterior Nonbearing Walls S 0' 0' 0' 0' 0' 0' 0' 0' 0' 0' <br /> Those members that shall be permitted to be of approved combustible material. <br /> 'See A-3-1 (table)from NFPA 220,Standard on Types of Building Construction. <br /> 2"H"indicates heavy timber members;see text for requirements. <br /> 3Exterior nonbearing walls meeting the conditions of acceptance of NFPA 285,Standard Method of Test for the <br /> Evaluation ofHammability Characteristics of ExteriorNon-Load-Bearing Wall Assemblies Containing Combustible Com- <br /> ponents Using the Intermediate-Scale,Multistory Test Apparatus,shall be permitted to be used. <br /> Annex C Glazing Materials pants. The degree of protection at the opening is intended to <br /> This annex is not a part of the requirements of this NFPA document provide a period of time for the safe egress of building occupants <br /> but is included for informational purposes only. in the vicinity of the exposed window area. <br /> C.1 The use of glass and other glazing materials in airport The presence of automatic sprinkler protection in the air- <br /> port terminal building would be expected to control a fire <br /> terminal building walls facing the ramp should be avoided if initiated in the building due to an exposure fire. Glazing ma- <br /> spillage from aircraft are less than 100 ft (30.5 m) from such <br /> the fueling ramp drainage inlets or the probable points of fuel terial above the 7 ft(2.1 m) finished floor level will not cause <br /> walls.This standard prohibits locating drainage inlets less than immediate exposure 2. building occupants. <br /> 50 ft (15 m) from any airport terminal building walls. Care should be exercised in the selection and adjustment <br /> This recommendation is made because the radiant heat of detection equipment to ensure proper operation and to <br /> release from a serious fuel spill fire can be expected to break guard against inadvertent operation of the system caused by <br /> glass windows up to 75 ft (22.9 m) away and cause ignition of normally fluctuating conditions.Due to the normal activity on <br /> combustible materials within the building. the airport ramp,the radiated energy of a spill fire might not <br /> Protection provided by automatically operated outside spray be received at a particular detector location but can still ex- <br /> nozzles is not intended to provide a safe refuge area for occu- pose the building wall. <br /> 2008 Edition <br />