My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3822 COLBY AVE DR KANG DDS 2017-08-18
>
Address Records
>
COLBY AVE
>
3822
>
DR KANG DDS
>
3822 COLBY AVE DR KANG DDS 2017-08-18
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/18/2017 2:34:02 PM
Creation date
8/10/2017 9:59:53 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
3822
Tenant Name
DR KANG DDS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Med'Icall Gas Servilces, LLC <br /> Level 3 Verification Check List <br /> Reference NFPA 99(2005ed) <br /> Job#: 798678 <br /> Facility: Dr.Alex Kang Tested By: HP Test Date: 11/20/14 <br /> Facility: ® New ❑ Existing Type of Facility: ® Dental ❑ Medical ❑Veterinary ❑ Lab ❑ Other: <br /> Medical Gases ❑ NONE <br /> Oxygen Line: ® New ❑ Existing Nitrous Oxide Line: ® New ❑ Existing ❑ NONE <br /> Line Pressure:50 psi Concentration: >99% Line Pressure: 50 psi Concentration: >99% <br /> Flow Test: SCFH (>_3.5 scfm j® Pass ❑ Fail Flow Test: SCFH (>_3.5 scfm)® Pass ❑ Fail <br /> Particulate Test: ® Pass ❑ Fail Particulate Test: ® Pass ❑ Fail <br /> Odor: ® Pass(None) ❑ Fail, Odor: ® Pass (None) ❑ Fail, <br /> Crossed Lines: ❑Yes ® No Outlet Brand: DISS fittings Quick Connect Style: NA <br /> Location of Outlets: 12 O'Clocks <br /> Cylinder Storage ❑ NONE <br /> Tank Room: ❑ New ® Existing Location: ® Inside ❑ Remote Door Labeled: ❑Yes ® No <br /> Individually Secured: ®Yes ❑ No Cooling Sprinkler: ®Yes ❑ No 1 Hour Rated: ®Yes ❑ No <br /> Separate from Mechanical Equipment: ®Yes ❑ No Electrical Switches/Outlets 5' above floor: ®Yes ❑ No <br /> Volume Connected or Stored: ® <3000 ft' ❑ >3000 ft' Number of Cylinders Connected: OX 2 x N20 2 <br /> Ventilation: ® Natural ❑ N/A Ventilation: ❑ Mechanical ® N/A <br /> 2 Openings l'of Floor&Ceiling: ®Yes ❑ No ❑ N/A Exhaust Fan Runs Continuously: ❑Yes ❑ No ® N/A <br /> Minimum 72 int Free Area: ®Yes ❑ No ❑ N/A Draws Air from within 1'of Floor: ❑Yes ❑ No ® N/A <br /> Vented to Exit Access Corridor: ❑Yes ® No ❑ N/A Fan Connected to Essential Power: ❑Yes ❑ No ®N/A <br /> Manifold ❑ NONE <br /> Manifold: ® New ❑ Existing Piping Labeled: ®Yes ❑No <br /> Brand: Porter Flex Hoses<5': ®Yes❑ No 1 Rigid Copper❑ Yes❑ N/A <br /> Model#:4222NOHF-1 Check Valve DL of Regulator: ®Yes ❑ No <br /> Serial#:42H!2624 Relief Valve 50%Above Norman Line Pres: ®Yes ❑ No <br /> Alarm/Warning System ❑ NONE <br /> Alarm: ® New ❑ Existing ❑ None—Not Required Non-Cancellable Visual Alarm: ®Yes ❑ No <br /> Brand: Porter Cancellable Audible Alarm: ®Yes ❑ No <br /> Model#:Vanguard A HI/LO Line Pressure Alarm: ® Yes ❑ No <br /> Serial#: KD98786 Reserve In Use Alarm/Change Over: ®Yes ❑ No <br /> KANG-11.20.14-Chklst-Level 3 Verification (2005ed) <br />