Application Annunciator Wiring <br /> R-Series annunciators communicate with the FACP on the RS-485 Annunciator, Class A <br /> data riser.This can be configured for Class A or Class B commu- <br /> nication.Annunciators do not provide ground fault isolation. FACP Annunciator Annunciator <br /> RS-485 IN cH 1(+)IN <br /> These annunciators are stand-alone units that can be powered by cri,+. CH1(-)IN CH (-)IN <br /> the FACP or by an approved power supply. <br /> CHI- cH,(+)our 0 CHI I.)OUT <br /> CH2+ cH,(-)OUT 0 CHI(-)OUT <br /> CH2- CH2(+)IN CH2(+)IN <br /> CH2(-)IN CH2(-)IN <br /> _ o r,,,,,,, LISTED 24 VDC CH2(+)OUT 0 CH2(+)OUT <br /> SUPPLY <br /> CH2(-)OUT 0 CH2(-)OUT <br /> ✓ .a a ✓ 24 VDC+ 24V(+)IN 24V(+)IN <br /> ®®® 4� 24 VDC- 24V(-)IN 24V <br /> o "o 24V(+j OUT 0 zaV(+)our <br /> 24V(-)OUT 0 24V(-)OUT <br /> GROUND GROUND <br /> RLCD-C RLED-C <br /> Annunciator,Class B <br /> a r...v..� s s s <br /> °rwwr o ° <br /> H <br /> FACP Annunciator Annunciator <br /> ✓ RS-485 C ,(+)IN CHI(+)IN <br /> ®®® ° CH1+ CH 7(-)IN CHI(-)IN <br /> g <br /> oil° CHI- CHI(+)OUT 0 CHI(+)OUT <br /> CHI(-)OUT 0 CHI(-)OUT <br /> 0CH2(+j IN 0 CH2(+)IN <br /> (2,CH2(-)IN 0 CH2(-j IN <br /> RLCD RLED24 LISTED 24 VDC 0 CH2(+)OUT 0 CH2(+)OUT <br /> Features by RLCD RLCD-C RLED-C RLED24 SUPPLY OCH2(-)OUT OCH2(-)OUT <br /> model 24 VDC+ 24V(+)IN 24V(+)IN <br /> Reset ✓ ✓ ✓ <br /> -- <br /> -. -_- __-- 24 VDC- 24V(-)IN 24V(-)IN <br /> 24V(+)OUT 0 24V(+)OUT <br /> ACIdSllence ✓ ✓ ✓ 24V(-)OUT 0 24V(-)OUT <br /> Fire Alarm ✓ ✓ ✓ <br /> GROUND GROUND <br /> Supervisory ✓ ✓ ✓ <br /> Ground Fault ✓ . ✓ <br /> Trouble ✓ ✓ ✓ <br /> Controls Enabled ✓ ✓ Expander <br /> Ack/Silence ✓ ✓ ✓ __ <br /> Reset Annunciator First Expander Sawnd Ezpande <br /> Signal Silence ✓ ✓ OUT IN OUT IN OUT <br /> V v(-j V(-j 0 - -- O V(-) V(-j 0 <br /> Drill ✓ ✓ vH v(+) V(+)0 - -------'--0v(-) V(H0 <br /> Lamp Test ✓ ✓ ✓ F F FO - -------,__0F Fe <br /> LCD Display ✓ ✓ E E E0- - ------ --0 E E0 <br /> Zone Active LEDs 16` 24" <br /> D D D0 - -------^-OD 00 1 <br /> Zone Trouble LEDs 16 24 c c Lc0 - ------;--Oc c0 <br /> B S a 0 - ------- O B 80 <br /> zones 13-16 may be selected as Supervisory on 1064 ; <br /> LA A A 0 _ ----------(D A A0 <br /> "zones 13-16 and 29-32 may be selected as Supervisory on 10500 <br /> Graphic Annunicator Interface <br /> The GCI Graphic Annunciator Driver is an interface card that <br /> connects the fire alarm control panel to the display panel of an Remote Keyswitch <br /> LED-based graphic annunciator. Annunciator LSRA-RK <br /> The annunciator card supports 32 LEDs and 16 switches on the KEYSWITCH(-) <br /> graphic panel display. It includes status LEDs and an internal KEYSWITCH <br /> buzzer. <br /> The graphic interface is supplied with snap track mounting. It is Keyswitch Specifications <br /> attached to a plastic mounting rail that requires two EIA panels. Maximum 5 vdc <br /> voltage ` <br /> The annunciator communicates with the FACP on the RS-485 Maximum 200 mA <br /> data riser.This can be configured for Class A or Class B commu- current <br /> nication.The annunciator does not provide ground fault isolation. Mounting 2-1/2 in(64 mm) <br /> It is a stand-alone unit that can be powered by the FACP or by an deep 1-gang box <br /> approved power supply. Termination Screw terminals <br /> Maximum 12 AWG <br /> Graphic Annunciator Interface Specifications wire size (2.5 mm sq) <br /> Alarm current 146 mA at 24 Vdc(with 36 LEDs ON) Contact Normally open <br /> Standby current 36 mA at 24 Vdc(with no LEDs ON) configuration _ �• <br /> Maximum current 10 mA per LED <br /> Page 2 of 4 85005-0128 <br /> Issue 2 <br />