My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6930 EVERGREEN WAY 2017-08-10
>
Address Records
>
EVERGREEN WAY
>
6930
>
6930 EVERGREEN WAY 2017-08-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/10/2017 2:37:34 PM
Creation date
8/10/2017 2:37:24 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
6930
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Lighting Summary LGT-SUM <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised August 2016 <br /> Project Info Project Title: Quality Funding LLC Date 8/23/2016 <br /> Compliance Applicant Information. Provide contact information for individual who can For Building Department Use <br /> forms do not respond to inquiries about compliance form information provided. <br /> require a Company Name: Quality Funding LLC <br /> password to <br /> use. Company Address: 6930 Evergreen Way,Everett WA 98203 <br /> Instructional and <br /> calculating cells Applicant Name: Sue Genty,Tricia Alexander(Sue Genty Interior Design) <br /> are write- <br /> protected. Applicant Phone: 425-827-3438 <br /> Applicant Email: sue@sgidinc.com,tricia@sgidinc.com <br /> Project Description ❑ New Building ❑Addition 0 Alteration ❑ Plans Included <br /> Include PROJ-SUM form(included in envelope forms workbook)with lighting complliance forms. <br /> Building Additions Compliance Method Interior lighting Exterior lighting <br /> Lighting systems in addition area comply with all applicable ❑ ❑ <br /> provisions as a stand alone neva construction project <br /> Refer to Section C502.2.6 for additional <br /> requirements. Lighting systems in addition are combined with existing a ❑ <br /> building lighting systems to demonstrate compliance <br /> Addition is combined with existing: <br /> For interior lighting projects.include new+existing interior lighting fixture wattage in Proposed Lighting <br /> Wattage table in LTG-INT-BLD or LTG-INT-SPACE form. <br /> For exterior lighting projects.include new+existing exterior lighting fixture wattage in Proposed <br /> Tradable and Proposed Non-Tradable Lighting Wattage tables in LTG-EXT form. <br /> Interior and Exterior Lighting Power Interior lighting Parking garage Exterior lighting <br /> Lighting Alterations 50%or more of existing are replaced ❑ ❑ ❑ <br /> Select ail Lighting Power and Lighting <br /> Control elements that apply to the scope Less than 50%of existing are replaced ❑ ❑ ❑ <br /> of the retrofit project. If project includes a <br /> combination of spaces where less than Lamp and/or ballast replacement only — <br /> 50%of the existing fixtures are replaced existing total wattage not increased ❑ ❑ ❑ <br /> in some spaces,and 50%or more of the 50%or more replaced-Total lighting power of new+existing-to-remain fixtures shall comply with total <br /> fixtures are replaced in others,then LPA per Sections C405.4.2 and C405.5.2. Include new+existing-to-rernain fixtures in Proposed <br /> provide separate lighting pourer Lighting Wattage table in LTG-iNT-BLD. LTG-INT-SPACE or LTG-EXT form. <br /> compliance forms for the Avo retrofit <br /> conditions.Spaces undergoing the same Less than 50%replaced- Total lighting power of new+existing-to-remain fixtures shall not exceed the <br /> type of retrofit may be combined into one total lighting pourer prior to alteration. Include new+existing-to-remain fixtures in the Proposed Lighting <br /> lighting power compliance form. Wattage table in LTG-INT-BLD. LTG-INT-SPACE or LTG-EXT form. <br /> 50%threshold applies to number of luminaires for interior spaces and parking garages. and total <br /> Refer to Section C503.6 for additional installed wattage for exterior luminaires. <br /> requirements. Lighting Controls Interior lighting Parking garage Exterior lighting <br /> All alteration lighting controls shall be New wiring installed to serve added <br /> commissioned per C408.3. fixtures and/or fixtures relocated to new ❑ ❑ ❑ <br /> circuits) <br /> New or moved lighting panel ❑ D. ❑ <br /> Interior space is reconfigured- 0 <br /> luminaires unchanged or relocated only <br /> New wiring or circuit-For interior lighting.provide required manual controls per C405.2.3, occupancy <br /> sensor controls per C405.2.1. daylight responsive controls per C405.2.4 and application specific lighting <br /> ❑ No changes are being made to <br /> controls per C405.2.5.For exterior lighting.provide required controls per C405.2.7. <br /> the interior or exterior lighting New or moved panel-Provide all applicable lighting controls as noted for New Wiring and automatic <br /> systems and existing space time switch controls per C405.2.2. <br /> uses and configuration are not Reconfigured interior space-Provide all required lighting controls that apply to a new interior space. <br /> changed. Application specific lighting control provisions per C405.2.5 do not apply to reconfigured spaces. <br /> Change of Space Use ❑ Existing interior lighting systems in areas under-going a change in space use are upgraded to <br /> comply with LPAs for the new space types per Tables C405.4.2(1)or C405.4.2(2). <br /> Identify interior spaces requiring LPD upgrade to the current Code in Proposed Lighting Wattage table in <br /> LTG-INT-BLD or LTG-INT-SPACE form. <br /> Y-3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.