My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2105 GRAND AVE 2017-08-18
>
Address Records
>
GRAND AVE
>
2105
>
2105 GRAND AVE 2017-08-18
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/18/2017 3:49:38 PM
Creation date
8/10/2017 2:59:43 PM
Metadata
Fields
Template:
Address Document
Street Name
GRAND AVE
Street Number
2105
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GILLUM ADDITION An I July 24, 2013 & SDA Job # 7030 6 <br /> UPPER FRONT INEARWALL WIND 1W SEISMIC <br /> Floor Info Tributary Width(Upper Floor) Tributary Area(Upper Floor) <br /> Upper Floor Level,e.g.Upper,Main,Lower F 1.0 tributary width F 1.0 tributary area <br /> Lt-Rt Load Direction,e.g.Left-Right,Front-Rear 2.0 total width =total area <br /> (For Left Wall,Use Front-Rear Load Direction) Tributary'Width(Main Floor) Tributary Area(Main Floor) <br /> CDX Sheathing type F-0.0tributary width F-T57 tributary area <br /> Values from table 2306.4.1 of the 2006 IBC F 1.0 total width 1.0 total area <br /> Roof Resisting Dead Load Tributary Width(Lower Floor) Tributary Area(Lower Floor) <br /> (e.g.Roof,Upper Floor,Main Floor) =tributary width 0.0 tributary area <br /> 2.50 Total Length of Shearwalls 1.0 total width =total area <br /> V(from upper)= 3432 Ib 2599 Ib Height of Shearwall= 8.0 ft Weight of Shearwall= 10.0 Ibs <br /> V(from main)= 0 Ib 0 Ib Length of Shearwall= 2.5 ft Tributary width for dead load= 4.0 ft <br /> V(from lower)= 0 Ib 0 Ib Aspect Ratio OK Length of adjoining wall= 4.0 ft <br /> I E(Wind)= 3,432 Ib E(Smc)= 2,599 Ib Use alternate R factor for seismic?F No <br /> V = 686 PLF V= 520 PLF <br /> 3x framing required per IBC <br /> IBC 2306.4.1 (2w/h) x 0.93 x 920=535 PLF -► USE6 <br /> S>eis:rlit:cont)ois sf)r;alvlfaii d>✓sfCn <br /> CTOTAL= (floor above)+(this floor)= + 5491 lbs = 5491 lbs Wind controls <br /> TTOTAL= (floor above)+(this floor)= + 5301 lbs = 5301 lbs Load case 8 controls-Wind <br /> 141ind controls hr>lGown de gn <br /> i--------------------------------------------------------------------------------------, <br /> Where overstrength factor is applicable,use this USE SIMPSON DESIGNED HOLDOWN: MSTC78 <br /> value for E in equations 5,6,and 8: E=3198 lbs I OR AT FOUNDATION/INTERIOR WALLS USE: �iDU8-SDS2.5 <br /> UPPER LEFT SHEARWALL WIND SEISMIC <br /> Floor Info Tributary Width(Upper Floor) Tributary Area(Upper Floor) <br /> Upper Floor Level,e.g.Upper,Main,Lower 1.0 tributarywidth 1.0 tributary area <br /> Ft-Rr Load Direction,e.g.Left-Right,Front-Rear 2.0 total width 2.0 total area <br /> (For Left Wall,Use Front-Rear Load Direction) Tributary Width(Main Floor) Tributary Area(Main Floor) <br /> CDX Sheathing type 1 0.0 Itributary width F 0.0 Itributary area <br /> Values from table 2306.4.1 of the 2006 IBC 1.0 total width 1.0 1 total area <br /> Roof Resisting Dead Load Tributary Width(Lower Floor) Tributary Area(Lower Floor) <br /> (e.g.Roof,Upper Floor,Main Floor) 0.0 tributary width 0.0 tributary area <br /> 6.00 ft Total Length of Shearwalls r 1.0 total width 1.0 total area <br /> V(from upper)= 3032 Ib 2599 Ib Height of Shearwall= 8.0 ft Weight of Shearwall= 10.0 Ibs <br /> V(from main)= 0 Ib 0 Ib Length of Shearwall= 2.5 ft Tributary width for dead load= 12.3 ft <br /> V(from lower)= 0 Ib 0 Ib Aspeci Ratio OK Length of adjoining wall= 4.0 ft <br /> E(Wind)= 3,032 Ib E(Smc)= 2,599 Ib Use alternate R factor for seismic?F No <br /> V = 253 PLF y= 217 PLF <br /> IBC 2306.4.1 ► (2w/h) x 0.93 x 380=221 PLF --► USE A2 <br /> Soismic controls sheanvail design <br /> CTOTAL= (floor above)+(this floor)= + 2021 lbs = 2021 lbs Wind controls <br /> TTOTAL= (floor above)+(this floor)= + 2044 lbs = 2044 lbs Load case 8 controls-Wind <br /> Wind);()ntrolS/)o/0ow/7 cies;go <br /> ------------------------------------------------------------------------'-------------i <br /> Where overstrength factor is applicable,use this USE SIMPSON DESIGNED HOLDOWN: F- CS14 <br /> -value for E in equations 5_6_and 8: -- - --- E= 1333 lbs OR AT FOUNDATION/INTERIOR WALLS USE: STHD8/RJ <br /> l <br /> ---' <br /> UPPER RIGHT SHEARWALL WIND SEISMIC <br /> Floor Info Tributary Width(Upper Floor) Tributary Area(Upper Floor) <br /> Upper Floor Level,e.g.Upper,Main,Lower 1.o tributary width 1.0 tributary area <br /> Ft-Rr Load Direction,e.g.Left-Right,Front-Rear 2.0 total width 2.0 total area <br /> (For Left Wall,Use Front-Rear Load Direction) Tributary Width(Main Floor) Tributary Area(Main Floor) <br /> CDX Sheathing type 15.0 tributary width 15.0 tributary area <br /> Values from table 2306.4.1 of the 2006 IBC 74.4 total width 74.4 total area <br /> Roof Resisting Dead Load Tributary Width(Lower Floor) Tributary Area(Lower Floor) <br /> (e.g.Roof,Upper Floor,Main Floor) 1 0.0 Itributarywidth 0.0 tributary area <br /> 17.00 ft Total Length of Shearwalls 1.0 total width 1.0 total area <br /> V(from upper)= 3032 Ib 2599 Ib Height of Shearwall= 8.0 ft Weight of Shearwall= 10.0 Ibs <br /> V(from main)= 0 Ib 0 Ib Length of Shearwall= 6.3 ft Tributary width for dead load= 12.3 ft <br /> V(from lower)= 0 Ib 0 Ib Aspect Ratio OK Length of adjoining wall= 4.0 ft <br /> E(Wind)= 3,032 Ib E(Smc)= 2,599 Ib Use alternate R factor for seismic?F No <br /> V = 89 PLF V= 76 PLF <br /> IBC 2306.4.1 --► 0.93 x 260=242 PLF ► USE 1A <br /> Seismic;ontrols shearvlafl design <br /> CTOTAL= (floor above)+(this floor)= + 713 lbs = 713 lbs Wind controls <br /> TTOTAL= (floor above)+(this floor)= + 744 lbs = 744 lbs Load case 8 controls-Wind <br /> ___________________________-VVir)d controlsholdowil cl sign <br /> Where overstrength factor is applicable,use this i USE SIMPSON DESIGNED HOEDOWN: 1 CS14 <br /> value for E in equations 5,6,and 8: -- --E=470 lbs - OR AT FOUNDATION/INTERIOR WALLS USE: STHD8/RJ <br />
The URL can be used to link to this page
Your browser does not support the video tag.