Laserfiche WebLink
Section <br /> # Mechanical Rough-in Inspection I Complies? I Comments/Assumptions <br /> &-Re q.ID _ <br /> C403.2.3 HVAC equipment efficiency verified. ❑Complies See the Mechanical Systems list for values. <br /> [ME55]2 ❑Does Not <br /> ❑Not Observable <br /> ❑Not Applicable <br /> C403.2.5. Demand control ventilation provided '❑Complies <br /> 1 for spaces>500 sq.ft. and >25 ❑Does Not <br /> [ME59]1 people/1000 sq.ft. occupant density <br /> and served by systems with air side ❑Not Observable <br /> economizer, auto modulating outside ❑Not Applicable <br /> air damper control, or design airflow <br /> >3,000 cfm. <br /> C403.2.7 HVAC ducts and plenums insulated. ❑Complies <br /> [ME60]2 Where ducts or plenums are installed ❑Does Not <br /> in or under a slab, verification may ❑Not Observable <br /> need to occur during Foundation <br /> Inspection. ❑Not Applicable <br /> C403.2.8 HVAC piping insulation thickness. ❑Complies <br /> [ME61]2 Where piping is installed in or under a ❑Does Not <br /> slab,verification may need to occur <br /> during Foundation Inspection. ❑Not Observable'. <br /> ❑Not Applicable <br /> C403.2.8. Piping Insulation exposed to weather ❑Complies <br /> 1 is protected from damage (due to sun, ❑Does Not <br /> [ME7]3 moisture, wind, etc.). <br /> ❑Not Observable <br /> ❑Not Applicable <br /> C403.2.8 Thermally ineffective panel surfaces of ❑Complies <br /> [ME41]3 sensible heating panels have ❑Does Not <br /> insulation >= R-3.5. <br /> ❑Not Observable <br /> ❑Not Applicable <br /> C403.3.1. Total cooling capacity without ❑Complies <br /> a economizers must be less than ❑Does Not <br /> [NA]0 %varMaxKBtuPerH%. <br /> ❑Not Observable <br /> ❑Not Applicable <br /> C403.2.7 Ducts and plenums sealed based on ❑Complies <br /> [ME10]2 static pressure and location. ❑Does Not <br /> ❑Not Observable <br /> ❑Not Applicable <br /> C403.2.7. Ductwork operating >3 in.water ❑Complies <br /> 1.3 column requires air leakage testing. ❑Does Not <br /> [ME11]3 []Not Observable' <br /> ❑Not Applicable <br /> C408.2.2. :Air outlets and zone terminal devices ❑Complies <br /> 1 have means for air balancing. ❑Does Not <br /> [ME53]3 ❑Not Observable <br /> ❑Not Applicable <br /> C403.4.2 VAV fan motors >=7.5 hp to be driven ❑Complies <br /> [ME66]2 by variable speed drive, have a vane- ❑Does Not <br /> axial fan with variable pitch blades, or <br /> have controls to limit fan motor ❑Not Observable <br /> demand. ❑Not Applicable <br /> C403.4.2 VAV fan motors >=7.5 hp to be driven ❑Complies <br /> [ME66]2 by variable speed drive, have a vane- ❑Does Not <br /> axial fan with variable pitch blades,or <br /> have controls to limit fan motor ❑Not Observable <br /> ❑ <br /> demand. Not Applicable <br /> 11 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact(Tier 3) <br /> Project Title: UBS-EVERETT Report date: <br /> Data filename: \\Cdpepc-fs-1\projects\UBS-\EVERETT, WA\PROJECT UBS-1172 1604 Hewitt Avenue, 6th Fir, PageQ�� <br /> Everett,WA\PROJECT INFORMATION\Com Check\LTG 2012.cck <br />