My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1604 HEWITT AVE UBS 2017-08-18
>
Address Records
>
HEWITT AVE
>
1604
>
UBS
>
1604 HEWITT AVE UBS 2017-08-18
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/18/2017 3:50:18 PM
Creation date
8/10/2017 3:50:56 PM
Metadata
Fields
Template:
Address Document
Street Name
HEWITT AVE
Street Number
1604
Tenant Name
UBS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
98
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0P . POTTER PSN SERIES <br /> ® The Symbol of Protection POWER SUPPLY <br /> PSN-106 Wiring Diagram <br /> N� 120/240 VAC GND FAULT <br /> N Jumper Position DETECT ENABLE <br /> ON R�:B- OFF <br /> 120VAC 50Hz-60Hz <br /> 240VAC 50Hz-6OHz Black <br /> Connect to separate white <br /> unswitched AC circuit Ground stows LEDs <br /> NACI NAC2 NAC3 NAC4 NAC5 NAC6 DCPWR <br /> FO Ss <br /> ®O <br /> Elo o[aeeN.1 <br /> 1I N � � COMM• <br /> 0 Fuse ❑ ll� o[c�oS <br /> I—I— ❑ El <br /> �U ❑ L _ ❑ <br /> ❑ ❑ <br /> FactoryInatalled ❑ ❑ ❑ <br /> Interconnect.AC Power El E] E] El El= <br /> Low Battery D <br /> rd Noll ❑ ❑ ❑ ❑ ❑ ❑ O O CONN.- <br /> 0 <br /> Ik options 0009 ❑ ❑ ❑ ❑ ❑ ❑ E o❑ ❑ ❑ ❑ <br /> ❑ N _ o -� <br /> Q L —� Q 11 <br /> At I NA(2 NAC3 NAC4 NAC6 D(:PWN Rtll; INl IN2 Q <br /> NC'LC'uM(NO NC CUM NO 'k—Battery <br /> Common relays are Battery- <br /> -to <br /> \. Re <br /> non-power limited. t hOL uL <br /> Lo.L <br /> DC Power Trig,, <br /> Battery connection(non-power limited). Note:PSN-64 and PSN-106 draw 15 mA when polarity reverses and the power <br /> Use two(2)12V batteries connected in series. supply is triggered.There is no current draw in Standby Mode. <br /> Engineering Specification <br /> The contractor shall supply and install the PotterPSN power supply.The assemblies.The LEDs shall have distinct flash patterns to provide further <br /> power supply shall operate on either 120 or 240 VAC input.The panel indication ofthe troubles present.The panel shall have selectable Trouble <br /> shall be capable of continuous load power without any degradation to Memory to provide the installer an indication that a past trouble existed <br /> the main supply or the distribution board.The cabinet shall be capable of on a circuit for diagnostic purposes. <br /> housing up to 18 AH batteries and the panel shall be capable of charging Each output ofthe power supply shall be capable of 3 amps of continuous <br /> up to 55 AH batteries in an external cabinet. power without degradation overtime.Thepowersupply shall provide for <br /> The panel shall have dip switches for simplistic configuration of the multiple circuits ofstrobe appliances.Thepowersupply shall synchronize <br /> system and LEDs to provide visual indicationto the installer ofthe status the flashes of any of the above listed strobe appliances on a per circuit <br /> ofthe system.The dip switches shall allow forAC power delay selection, basis. Up to four ditterent strobe circuits may be connected and all of <br /> Class AB operation per output,Door Holder Power options,constant the strobes shall flash in unison as required by UL 864.In addition to <br /> auxiliary power,trigger input type,ANSI Code 3 Temporal Code,Pass this Quadrasync feature, the panel shall allow any of the tour above <br /> Thru(input tracking),Potter/AMSECOO sync,Gentex"Sync,System mentioned sync patterns as an input and pass this signal through and <br /> Sensoe Sync or Wheelock'sync.The LEDs shall provide indication synchronize the outputs to match the input flash pattern. <br /> of communication between the power supply and distribution circuit <br /> PRINTED IN USA MKT.#8910013-REV C2 PAGE 2 OF 2 <br /> II/12 �/L/ <br />
The URL can be used to link to this page
Your browser does not support the video tag.