My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1604 HEWITT AVE UBS 2017-08-18
>
Address Records
>
HEWITT AVE
>
1604
>
UBS
>
1604 HEWITT AVE UBS 2017-08-18
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/18/2017 3:50:18 PM
Creation date
8/10/2017 3:50:56 PM
Metadata
Fields
Template:
Address Document
Street Name
HEWITT AVE
Street Number
1604
Tenant Name
UBS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
98
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Conventional GC Series Wiring Diagrams <br /> UL Listed <br /> UL Listed Control <br /> Control Panel Signal Signal <br /> Signal Signal s+ S+ s- H+ is+ S+ S- H+ H- <br /> Panel Supervised S+ S+ S- H+ H- S+ S+ S- H+ H- P <br /> Supervised 0 0 0 0 Signal Circuit <br /> Signal Circuit \ + <br /> ENE IS LINE <br /> \ + - RESISTOR <br /> END OF LINE <br /> RESISTOR + <br /> \ END LINE <br /> RESISTOR <br /> NOTES: <br /> • All strobes are designed to flash as specified with continuous applied voltage. Strobes should not be used on coded or pulsing <br /> signaling circuits. However, use of the Gentex AVSM control module or Gentex synchronization protocol is permitted to synchronize <br /> the strobe, horn and/or mute the horn. See Technical Bulletin 014 for additional information. <br /> • FOR SYNCHRONIZATION WIRING INFORMATION, REFERENCE AVSM CONTROL MODULE DATA SHEET(551-0031) <br /> AND/OR AVSM CONTROL MODULE MANUAL(550-0284)FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS. AVSM <br /> CONTROL MODULE DATA SHEET AND MANUAL CAN BE OBTAINED AT http://www.gentex.com OR CALL GENTEX <br /> CORPORATION AT 1-800-436-8391. <br /> Architect & Engineering Specifications <br /> The visible and audible/visible signal shall be Gentex model GCS or GCC or approved equal and shall be listed by <br /> Underwriters Laboratories Inc.per ANSI/UL 1971 for the GCS and ANSI/UL 464 for the GCC.The notification appliance <br /> shall also be listed with the California State Fire Marshal (CSFM) and the Bureau of Standards and Appeals (NYC). <br /> The notification appliance (combination audible/visible units and audible units only) shall produce a peak sound output <br /> of 90dBA or greater as measured at 24VDC in an anechoic chamber.The signaling appliance shall also have the <br /> capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power <br /> wires.Additionally, the user shall be able to select either continuous or temporal tone output with the temporal signal <br /> having the ability to be synchronized. <br /> The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of 1 Hz or up to 2Hz <br /> regardless of power input voltage. The appliance shall have an operating current of 72mA or less at 24VDC for the 15 <br /> candela strobe circuit. <br /> The appliance shall be polarized to allow for electrical supervision of the system wiring.The unit shall be provided with <br /> a mounting bracket with terminals with barriers for input/output wiring and be able to mount to a single gang or double <br /> gang box or double workbox with the use of an adapter plate.The unit shall have an input voltage range of 16-33 volts with <br /> either direct current or full wave rectified power. <br /> The appliance shall be capable of test supervision without disconnecting wires, verify voltage without removing unit and <br /> be capable of mounting to a surface back box. <br /> 24 units per carton <br /> 29 pounds per carton <br /> Important Notice: 551-0051-06 <br /> G E N T E X These materials have been prepared by Centex Corporation("Gentex")for Informational purposes only,are <br /> necessarily summary,and are not purported to serve as legal advice and should not be used as such. <br /> Centex makes no representations and warranties,express or Implied,that these materials are complete and <br /> CORPORATION p-to- <br /> ccurate,udate,or In rompliance with all relevant local,state and federal laws,regulations and rules. <br /> The materials do not address all legal considerations as there is inevitable uncertainty regarding <br /> Fire Protection Products Grou •www.r entex.com Interpretation of laws,regulations and rules and the application of such laws,regulations and rules to <br /> p 9 particular fact patterns.Fach person's activities can differently affect the obligations that exist under <br /> 10985 Chicago Drive •Zeeland, Michigan 49464 applicable laws,regulations or rules.Therefore,these materials should be used only for informational / <br /> purposes and should not be used as a substitute for seeking professional legal advice.Gentex will not be / <br /> 616.392.7195 • 1.800.436.8391 • 616.392.4219 Fax responsible for any action or tailum to act In reliance upon the information contained m this material. <br /> Gentex Corporation reserves the right to make changes to the product data sheet at their discretion. <br />
The URL can be used to link to this page
Your browser does not support the video tag.