SCOPE OF WORK GENERAL NOTES: Smart Energy Today Inc." <br /> PHOTOVOLTAIC SYSTEM SUMMARY 1. AN INVERTER OR AN AC MODULE IN AN INTERACTIVE PHOTOVOLTAIC SYSTEM SHALL AUTOMATIC ALL DE-ENERGIZE ITS OUTPUT TO THE SOLAR <br /> CONNECTED ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN THAT SYSTEM AND SHALL REMAIN IN ^`.IFW` <br /> SYSTEM SIZE:DC STC-5.80 KW THAT STATE UNTIL THE ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED.(NEC 690361). '* <br /> 2. ALL EXTERIOR ELECTRICAL METALLIC TUBING(EMT)CONDUIT FITTING SHALL BE RAIN TIGHT THREAD-LESS COMPRESSION TYPE. <br /> MODULES:(20)iTEK ENERGY 7290-SE SOLAR MODULE 3. MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED. <br /> MODULE MX POWER(P/MAX):29OW 4. NAMEPLATES SHALL BE PROVIDED FOR ALL CIRCUITS IN THE SERVICE DISTRIBUTION AND POWER DISTRIBUTION SWITCH BOARDS,PANEL - 1001 Cooper Point Rd SW. <br /> INVERTER:(10)BLUE FROG SOLAR YC500A-MIW BOARDS,DISCONNECTING SWITCHES,TERMINAL CABINETS,ETC.ALL NAMEPLATES SHALL BE PERMANENTLY ATTACHED AND BE OF Suite 140-290 <br /> MICROINVERTER SUFFICIENT CAPACITY TO WITHSTAND THE WEATHER. _ �` Olympia,WA 98502 <br /> 5. JUNCTION BOX/COMBINER BOX HAVE TO USE COMPRESSION TYPE STRAIN RELIEF POSITIONED FOR APPROPRIATE WATER RUN OFF. \ t T` Phone:888405-8689 <br /> 6. CONDUIT RUNS SHALL BE PROVIDED WITH SUFFICIENT WEATHERPROOF PULL BOXES OF JUNCTION BOX/COMBINER BOXES PER Fax:855-350-9430 <br /> ARRAY TILT: APPROPRIATE NEC REQUIREMENTS. ! "�*' support@smartenergytoday.net <br /> ROOF#1:22' 7, SEE PROVIDED CUT SHEETS FORADDITIONAL EQUIPMENT SPECIFICATIONS. <br /> AZIMUT:: 8. WIRING MATERIALS SHALL BE SUITABLE FOR THE SUN EXPOSURE AND WET LOCATIONS.FIELD APPLIED PROTECTIVE COATINGS ARE NOT - <br /> AZIMUTH: '.n REVISIONS <br /> ACCEPTABLE. <br /> ROOF#1:268' ,, oEscwvnoN DATE Ixev <br /> ROOF#2:192' 9. JUNCTION,PULL AND OUTLET BOXES LOCATED BEHIND MODULES SHALL BE SO INSTALLED THAT THE WIRING CONTAINED IN THEM CAN BE <br /> RENDERED ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF MODULE(S)SECURED BY REMOVABLE FASTENERS AND CONNECTED BY A / �, INITwI .12-17 00 <br /> ELECTRICAL INFORMATION FLEXIBLE WIRING SYSTEM.(NEC 690.34). ' <br /> COUNTY:SNOHOMISH 10, IN AN UNDERGROUND PHOTOVOLTAIC SYSTEM,THE POWER SOURCE SHALL BE LABELED WITH THE FOLLOWING WARNING AT EACH E <br /> UTILITYCOMPANY:SNO PUD JUNCTION BOX,COMBINER BOX,DISCONNECT AND DEVICE WHERE THE UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE: i <br /> N SERVICE AMPERAGE:200A WARNING-ELECTRIC SHOCK HAZARD.THE CURRENT CIRCUIT CONDUCTORS OF THIS PHOTOVOLTAIC POWER SYSTEM ARE UNGROUNDED I Signature win Seal <br /> ILDING INFORMATION:SINGLE STORY HOUSE BUT MAY BE ENERGIZED WITH THE RESPECT TO GROUND DUE TO LEAKAGE PATHS AND/OR GROUND FAULTS.-(NEC 690.35(F)). I x <br /> OF:COMPOSITE SHINGLE 11. ALL PHOTOVOLTAIC MODULES AND ASSOCIATED EQUIPMENT AND WIRING MATERIAL SHALL BE PROTECTED FROM ANY PHYSICAL DAMAGE <br /> 12. ALL ELECTRICAL DEVICES AND UTILIZATION EQUIPMENT SHALL BE LISTED BY AN APPROVED TESTING AGENCY. <br /> UMBER OF LAYERS:01 ' <br /> ANNUAL AVERAGE WIND SPEED:110 MPH 13. OUTDOOR EQUIPMENT SHALL BE AT LEAST NEMA 3R RATED. <br /> GROUND SNOW LOAD:15 PSF 14. ALL SPECIFIED WIRING IS BASED ON THE USE OF COPPER <br /> 15. CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS AND SHALL COORDINATE ALL INSPECTION,COMMISSIONING AND ACCEPTANCE WITH , 0 <br /> THE CLIENT,UTILITY CO.AND CITY INSPECTORS AS NEEDED. `. • "` <br /> 16. DRAWINGS ARE DIAGRAMMATIC ONLY,ROUTING OF RACEWAYS SHALL BE AT THE OPTION OF THE CONTRACTOR UNLESS OTHERWISE <br /> NOTED AND SHALL BE COORDINATED WITH OTHER TRADE. <br /> CODE SUMMARY 17. IF DISTANCES OF CABLE RUNS ARE DIFFERENT THAN SHOWN,THE CONTRACTOR SHALL NOTIFY ELECTRICAL ENGINEER TO VALIDATE THE <br /> 2015WASHINGTON STATE BUILDING CODE(201518C) WIRE SIZE.FINAL DRAWINGS WILL BE REDLINED AND UPDATED AS APPROPRIATE. _ -_ -- <br /> 2015 WASHINGTON STATE ENERGY CODE(20151ECC) 18. WHENEVER A DISCREPANCY IN QUANTITY OF EQUIPMENT,ARISES ON THE DRAWINGS OR SPECIFICATIONS,THE CONTRACTOR SHALL BE d t- PROJECT NAME 8 ADDRESS <br /> 2015 WASHINGTON STATE RESIDENTIAL CODE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL MATERIAL AND SERVICES REQUIRED BY THE STRICTEST CONDITIONS NOTED ON THE <br /> 12015 INTERNATIONAL RESIDENTIAL CODE WASHINGTON DRAWINGS OR IN THE SPECIFICATIONS TO ENDURE COMPLETE COMPLIANCE AND LONGEVITY OF THE OPERABLE SYSTEM REQUIRED BY AERIAL VIEW <br /> AMENDMENTS 2014 WAC51.51-2300 SECTION M2302) THE ARCHITECT/ENGINEER Z <br /> 2014 WAC 296-468(2014 NEC) 19. ALL BROCHURES,OPERATION MANUALS,CATALOGS,SHOP DRAWINGS,ETC.SHALL BE HANDED OVER TO THE OWNER'S REPRESENTATIVE PV-O SCALE:NTS <br /> 2015 WASHINGTON STATE MECHANICAL CODE(2015 UMC) AT THE COMPLETION OR WORK, J <br /> 2015 WASHINGTON STATE PLUMBING CODE(2015 UPC) 20. ALL WIRING CONCEALED IN WALL AND CEILING SPACES SHALL BE IN METAL CONDUIT. <br /> 2015 WASHINGTON STATE FIRE CODE(2015 IFC) 21. THE SEISMIC BRACING AND ANCHORAGE OF ELECTRICAL CONDUITS SHALL BE IN ACCORDANCE WITH THE'SMACNA%GUIDLINES FOR f <br /> SEISMIC RESTRAINS OF MECHANICAL SYSTEMS AND PLUMING PIPING SYSTEMS. 1, ttt' , { _ % <br /> 22. ALL OF THE LISTED SYSTEMS REOUIRED THAT THE SEISMIC LATERAL FORCE F INCLUDING CONSIDERATION OF a^P AND MP BE . M L ^"" Z Q N <br /> DETERMINED AT EACH LEVEL OF THE BUILDING SO THAT BRACE SPACING CAN BE CALCULATED.THE DISTRICT STRUCTURAL ENGINEER �G/L A <br /> SHEET INDEX AN L FORCE DETERMINATION, <br /> 23. A COPY OF THE CHOSEN BRACINVE THE SEISMIC G SYSTEMS)INSTALLATION GUIDEIMANUAL SHALL BE ON THE JOB SITE PRIOR TO STARTING THE t LL N d <br /> PVLO COVER SHEET :-.. - LL Q' ('rl V CL <br /> INSTALLING OF HANGERS AND/OR BRACES. <br /> PV-1 PLOT PLAN WITH ROOF PLANS _ 1 �. N O <br /> 24, WHEN INSTALLING DRILLED414 ANCHORS AND/OR POWDER DRIVEN PINS IN EXISTING NON-PRESTRESSED REINFORCED CONCRETE,USE <br /> PV-2 ROOF PLAN WITH MODULES CARE AND CAUTION TO AVOID CUTTING OR DAMAGING THE REINFORCED BARS.WHEN INSTALLING THEM INTO EXISTING PRE-STRESSED ,. r M J 00 <br /> PV-3 ATTACHMENT DETAIL CONCRETE TENDONS BY USING A NON-DESTRUCTIVE METHOD PRIOR TO INSTALLATION.EXERCISE EXTREME CARE AND CAUTION TO -� 'F <br /> PV-4 ELECTRICAL LINE DIAGRAM AVOID CUTTING OR DAMAGING THE TENDONS DURING INSTALLATION.MAINTAIN A MINIMUM CLEARANCE OF ONE INCH BETWEEN THE , 'lo .^'� � U Q N to <br /> PV-5 PLACARDS REINFORCEMENT AND THE DRILLED-IN ANCHOR. ^ D v <br /> PV-6+ MANUFACTURER SPEC SHEET 25, THE WORKING CLEARANCES AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE NEW ELECTRICAL EQUIPMENT WILL BE <br /> MAINTAINED IN ACCORDANCE WITH NEC 110.26. ' a - ' <br /> E <br /> 26. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT.(NEC 300.6 01,310.8 D ¢ q� O Z <br /> 27. GROUNDING BUSHINGS ARE REQUIRED AROUND PRE-PUNCHED CONCENTRIC KNOCKOUTS ON THE DC SIDE OF THE SYSTEM.(NEC 250.97) x 7 W O E <br /> 28. THE GROUNDING ELECTRODE CONDUCTOR MUST BE PROTECTED FROM PHYSICAL DAMAGE IF SMALLER THAN#6 COPPER WIRE.(NEC • ' t r p L <br /> 250.64 B). q .-:; - ! k- d J <br /> 29. GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS,EXCEPT FOR SPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT. 'S r`�-- F' ,.,.,� - L.I-� <br /> (NEC 250.64 C). � 1` ) w W a <br /> 30. RACEWAY FOR GROUNDING ELECTRODE CONDUCTOR SHALL BE BONDED AT EACH END.(CEC 250.64(E). W <br /> 31. WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION,A SIGN WILL BE PROVIDED WARNING <br /> OF THE HAZARD PER NEC 690.17.34.EACH UNGROUNDED CONDUCTOR OF THE MULT-IWIRE BRANCH CIRCUIT WILL BE IDENTIFIED PER [[[ !`, -J <br /> PHASE AND SYSTEM PER NEC210.5. " ))))� I � O <br /> 32. CIRCUITS OVER 250V 70 GROUND SHALL COMPLY WITH NEC250.97 8250.92(B)&LAMC 93.250.97. <br /> 33. DC CONDUCTORS EITHER DO NOT ENTER THE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR ENCLOSURES TO THE FIRST 0 <br /> ACCESSIBLE DC DISCONNECTING MEANS PER NEC 690.31(E),LAMC 93.690.31(E). r , t` ` ) f <br /> 34. ALL METALLIC FRAME RAILS AND OTHER CURRENT CARRYING METALLIC COMPONENTS(CONDUIT,JUNCTION 8 PULL BOXES,RACEWAY, . 4 1 " <br /> ETC)SHALL BE SOLIDLY GROUNDED PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS LAMC 93.690.110.3 893.110.3(B). - :, <br /> 35. SCREWS,NUTS,BOLTS 8 WASHERS THAT ATTACH EQUIPMENT GROUNDING LUGS SHALL BE STAINLESS STEEL LAMC 93.110.3(B). 4 SHEET NAME <br /> 36. NO PIPING,DUCTS OR EQUIPMENT FOREIGN TO ELECTRICAL EQUIPMENT SHALL BE PERMITCOVER SHEET <br /> TED TO BE LOCATED WITHIN THE DEDICATED <br /> SPACE ABOVE THE ELECTRICAL EQUIPMENT. <br /> 37. ALL FIELD INSTALLED JUNCTION,PULL AND OUTLET BOXED LOCATED BEHIND MODULES OR PANELS SHALL BE ACCESSIBLE DIRECTLY OR e 1 �#�. r '�' S <br /> BY DISPLACEMENT OF A MODULE(S)OR PANEL(S)SECURED BY REMOVABLE FASTENERS. t > T <br /> 38. REMOVAL OF A DWP-INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE -= - SHEET SIZE <br /> GROUNDING ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTOR. - <br /> 39. THE ROOF MOUNTED PHOTOVOLTAIC MODULES,PANELS,OR SOLAR VOLTAIC ROLL ROOFING MATERIAL SHALL HAVE THE SAME OR ANSI B <br /> BETTER LISTED FIRE-RESISTANCE RATING THAN THE BUILDING ROOF-COVERING MATERIAL. Afit` 11" <br /> 40. ALLROOF MOUNTED CONDUIT WILL BE A MINIMUM 6'OFF THE ROOF SURFACE. X 17", <br /> 2 VICINITY MAP SHEETNUMEER <br /> PV-0 SCALE:NTS PV-O <br />