ENG/NEENING/PIMIC NERYICES OEP"TANENT <br /> September 19, 2016 <br /> Tom Deering <br /> Tom.deeringC@synthesispllc.com <br /> RE: Owner: Underwood Gartland Everett LLC <br /> Job Address: 6201 Associated Blvd Bldg. B <br /> Plan Check No: B1609-015 <br /> Dear Mr. Deering, <br /> In response to your application for a construction permit, your plans have been examined and you are <br /> advised that revisions may be necessary before a permit can be issued. Please review and respond to the <br /> comments below. These comments address building issues only. Additional revisions or additions may be <br /> required by other departments (such as Utilities, Planning or Fire). All references refer to the 2015 <br /> International Building Code (IBC), the 2015 International Existing Building Code (IEBC), the 2015 <br /> International Property Maintenance Code (IPMC), the 2015 International Fire Code (IFC), the 2015 <br /> International Mechanical Code (IMC), and the 2015 International Energy Conservation (IECC), as <br /> amended by the State of Washington (WSEC) and adopted by the city of Everett. The current IBC <br /> referenced standard for accessible design is the 2009"Accessible and Usable Buildings and Facilities" <br /> (ICC/ANSI A117.1). Federal ADA, FHA, and HUD regulations and standards, including the Fair Housing <br /> Accessibility Guidelines may be more restrictive. <br /> In order for the processing of your application to continue, it will be necessary to provide the <br /> Building Division with two complete new sets of construction documents reflecting the <br /> corrections requested. <br /> 1. Everett Municipal Code, 16.01.040 states"Where elevators are required in <br /> buildings, at least one elevator shall be provided for Fire Department emergency <br /> access to all floors. The elevator car shall be of such a size and arrangement to <br /> accommodate a 24-inch by 84-inch ambulance stretcher, with not less than 5- <br /> inch radius corners, in the horizontal, open position and shall be identified by the <br /> international symbol for emergency medical services (star of life). The symbol <br /> shall not be less than 3 inches high and shall be placed inside on both sides of <br /> the door frame". <br /> 2. The plans indicate, as is required by the IMC, a type 1 hood above the stove in <br /> the kitchen. This installation will require its'own separate permits but the <br /> submitted plans do not appear to address the proper configuration or provision <br /> for the grease duct. <br /> 3. A lighting budget to verify compliance with the WSEC is required either with this <br /> submittal or with the electrical permit application. <br /> If you have any questions, please call me at 425-257-7264. <br /> Upon submittal of the drawings, your application will be given priority and plan reviews will recommence. <br /> CITY OF EVERETT • 3200 Cedar Street • Everett, WA 98201 • (425) 257-8800 • Fax (425) 257-8856 �� <br />