Laserfiche WebLink
Interior Lighting - Space-..y-Space Method LTG-INT-SPACE <br /> 2015 Washington State EnergyCode Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised August 2016 <br /> Project Title: Columbia Distributing TI Date 9/14/2016 <br /> Calculation • Mdition- Addition For Building Department Use <br /> Area NOTES stand alone +existing <br /> I, Spaces where<50%of * Spaces where_ 50%of o <br /> luminaires are replaced luminaires are replaced <br /> LPA • Standard al Additional Efficiency Package Option o <br /> Calculation 0406.3 Reduced Interior Lighting Power <br /> To comply with C406.3,the Proposed LPD shall be 25%lower than the Target LPA <br /> Type Refer to C406.3 for additional requirements. <br /> Maximum Allowed Lighting Wattage NOTE1 <br /> Location(plan#, Ceiling Gross Interior Allowed Watts Allowed <br /> room#) Space Type Height NOTE2 Area in ft2 Watts per ft2 (watts/ft2 x area) <br /> Classroom/lecture/training 2142 1.000 2142 <br /> Conference/meeting/multipurpose 1002 0.980 982 <br /> Corridor:all other 1835 0.530 973 <br /> Food preparation 296 0.790 234 <br /> Lobby:all other 482 0.720 347 <br /> Office:Enclosed 3817 0.890 3397 <br /> Office:Open plan 2628 0.780 2050 <br /> Lounge/breakroom:all other 878 0.580 509 <br /> Stairwell 137 0.550 75 <br /> Restroom:all other 844 0.780 658 <br /> Storage room 189 0.500 95 <br /> Workshop 622 1.270 790 <br /> Electrical/mechanical 199 0.760 151 <br /> Total Area 15071 ' <br /> Retail Display Allowance from LTG-INT-DISPLAY <br /> Lobby Art/Exhibit Display Allowance from LTG-INT-DISPLAY NOTE8 Allowed Watts 12403 <br /> Proposed Lighting Wattage""'t' <br /> Watts/ <br /> Location(plan#, 5 6 Number of ��� <br /> NOTE 4, , Watts <br /> room#) Fixture Description Fixtures Fixture Proposed <br /> 2x4 Fluorescent 160 67 10720 <br /> Down Lights 55 15 825 <br /> Strip Lights(#of 4'segments) 26 32 832 <br /> Proposed Retail Display Lighting from LTG-INT-DISPLAY <br /> Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts 12377 <br /> Interior Lighting Power Allowance COMPLIES <br /> Note 1-List all unique space types per Table C405.4.2(2)that occur in the project scope.Select space type category per from drop down menu. <br /> Note 2-Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2),Footnotes d thru f <br /> Note 3-List all proposed lighting fixtures including exempt lighting equipment and existing-to-remain fixtures. <br /> Note 4-For proposed Fixture Description,indicate fixture type,lamp type(e.g.T-8),number of lamps in the fixture,and ballast type(if included).For <br /> track lighting,list the length of the track(in feet)in addition to the fixture,lamp, and ballast information. <br /> Note 5-For lighting equipment eligible for exemption per C405.4.1,note exception number and leave Watts/Fixture blank. <br /> Note 6-Existing-to-remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures.Identify as existing <br /> in fixture description. <br /> Note 7-For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source.For <br /> luminaires with screw-in lamps,enter the manufacturer's listed maximum input wattage of the fixture(not the lamp wattage).For low voltage <br /> lighting,enter the wattage of the transformer.For line voltage track/busway systems,enter the larger of the attached luminaire wattage or 50 <br /> watts/lineal foot,or enter the wattage limit of permanent current limiting device. <br /> Note 8-Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage. <br /> Note 9-Calculation Area Details: <br /> a.Lighting fixtures in a building addition may comply as a stand alone project,or they may be combined with the overall existing building <br /> lighting systems to demonstrate compliance.Refer to C502.1. <br /> b.For alterations and building additions,provide Space Types and gross interior areas in the Maximum Allowed Lighting Wattage table.If a <br /> building addition will comply as combined with the overall existing building lighting systems,include all applicable existing Space Types <br /> and gross interior areas. <br /> c If less than 50%of existing lighting fixtures will be replaced provide total existing lighting wattage(prior to alteration)in the space provided <br />