Vertical Fenestratioi argetAdjustment • <br /> If vertical fenestration area exceeds maximum allowed perSection C402.3.1,then Target Area Adjustment of all applicable envelope elements is required <br /> This worksheet automatically calculates these adjustments and updates target areas in the ENV-UA and ENV-SHGC worksheets. Information shown in <br /> this worksheet is for reference only and is write-protected.Submit this Target Area Adjustment form with ENV-UA and ENV-SHGC forms. <br /> VF=Vertical fenestration NW=Net above grade w all(excludes fenestration and doors.) <br /> DR=Opaque doors Gross Exterior Above-Grade Wall Area=VF+NW+DR <br /> AG=Above rade <br /> Proposed Areas <br /> Vertical Fenestration-> VF= 5287.0 <br /> Opaque-> NW= 67219.0 DR= 5619.0 <br /> Gross Exterior Max Vert.Fen.% Maximum Target <br /> AG Wall Area (0402.3.1) Vert.Fen.Area <br /> 78125.0X 30.0$ - 100 = 23437.5 <br /> Iotal Vertical Uelta Vertical Excess Vertical <br /> Fenestration Maximum Target Fenestration 0 Fenestration <br /> 5287.0 - 23437.5 = -18150.5 F; greater = <br /> -18150.5 <br /> Multiplier applied to all <br /> Total Vertical Excess Vertical Target Vertical Total Vertical Proposed Vertical <br /> Fenestration Fenestration Fenestration Fenestration Target VF Multiplier Fenestration Areas to <br /> 5287.0 - = 5287.0 - 5287.0 = 1.00 calculate Target Vertical <br /> Fenestration Area <br /> Net AG Wall Area Excess Fenestration Target Net Wall Area Net Wall Target Net Wall Milt. Multiplier applied to all <br /> 67219.0 + = 67219.0 - 67219.0 = 1.00 Proposed Opaque Above- <br /> Grade Wall Areas to <br /> TaretAbove- <br /> UA Adjustments cal ulate Grade Wal Area <br /> Vertical Fenestration Proposed Area Target VF Mult. Target Area <br /> Non-metal frame X <br /> Metal frame,fixed 5077.0 X 1.00 = 5077.0 <br /> Metal frame,operable X = <br /> Metal frame,entrance door 210.0 X 1.00 = 210.0 Target areas in shaded <br /> Above-grade Wall Proposed Area Target Net Wall Mult. Target Area boxes are applied to <br /> Steel FrameX = target areas on ENV-UA <br /> Metal Building = <br /> Wood I Other frame X = <br /> Mass 67219.0 X 1.00 = 67219.0 <br /> Sum of target ab ove-grade <br /> Sum of Proposed 72506.0 Sum of Target 72506.0 wall and vertical <br /> fenestration areas are <br /> calculated to equal the <br /> SHGC x A Adjustments sum of proposed <br /> Non-North Vertical Fenestration Proposed Area Target VF Mult. Target Area <br /> PF<0.2 4795.0 X 1.00 = 4795.0 <br /> 0.2!5 PF<0.5 X _ <br /> PF>-0.5 492.0 X 1.00 = 492.0 SHG C target areas in <br /> North Vertical Fenestration shadedboxes are applied <br /> to targetareas on ENV- <br /> PF<02 X = SHGC <br /> 0.2!5 PF<0.5 X = <br /> PF>-0.5 X = <br />