Laserfiche WebLink
MMM3RMMfl <br /> • OWN Mm• <br /> 2012 Washington State Energy Code C nce Forms for Commercial Buildings including R21M over 3 stories and all R1 Revised Oct 2013 <br /> Project Address Underwood Gartland 62 Date 06/21/2016 <br /> u 6.8% Max.Target: 30% For Building Department Use <br /> Fenestration Area as /o gross above-grade wall area 9 <br /> Skylight Area as%gross roof area 1.3% Max.Target: 5% <br /> Vertical Fenestration Alternates: None Selected on ENV-SUM <br /> Notes: 1-Proposed vertical fenestration and skylight areas entered in ENV-SHGC must match proposed <br /> fenestration areas in ENV-UA. <br /> 2-If Target Area Adjustment is required per ENV-UA,then target areas will be automatically <br /> adjusted in ENV-SHGC. Refer to Target Area Adjustments worksheet for this calculation. <br /> 3-Provide NFRC rated SHGC or default from Table C303.1.3(3)for fenestration assembly SHGC. <br /> 4-Fenestration that separates conditioned space from a non-conditioned or semi-conditioned <br /> space shall be included in this worksheet. <br /> Skylights Proposed SHGC Target SHGC <br /> Provide source of SHGC,page/plan#of assembly detail&ID SHGC x Area(A) =SHGC x I SHGC x Area(A)= SHGC x A <br /> ID:SkyCo-SKYPRO IR Illuminator 0.38 2560 973 0.35 2560 896.0 <br /> ID: (Product SHGC=0.25-Maximum allowable shown here) SHGC 0.35 <br /> ID: <br /> ID: <br /> ID: <br /> Totals 2560.0 972.8 Totals 2560.0 896.0 <br /> All Non-North Vertical Fenestration+ Proposed SHGC Target SHGC++ <br /> Provide source of SHGC,page/plan#of assembly PF SHGC* x Area(A)=SHGC x A PF SHGC x Area(A)= SHGC x A <br /> detail&ID Category <br /> ID:NonShaded 0 0.40 4627 1851 PF<0.2 0.40 4795 1918.0 <br /> ID:Shaded 0.50 0.48 450 216 0.2:5PF<0.5, 0.48 <br /> ID: 0 PF>_0.5 0.64 492 315 <br /> ID:Entry Doors Non Shaded 0 0.40 168 67 ++If projection factor(PF)credits are <br /> ID:Entry Doors-Shaded 0.50 0.48 42 20 applied to the proposed design, Target <br /> ID: 0 SHGC will sum fenestration area by PF <br /> ID: o category. <br /> ID: 0 <br /> ID: 0 <br /> ID: 0 <br /> +If projection factor credit is applied, then vertical Totals 5287.0 2154.2 Totals 5287.0 2232.9 <br /> fenestration must be entered in the correct table according to <br /> orientation. If credit is not applied then all vertical <br /> fenestration can be entered in either table. <br /> *Note:Fenestration that separates conditioned space from a <br /> non-conditioned or semi-conditioned space shall be listed <br /> here with a proposed SHGC equal to the target value. <br /> North Vertical Fenestration+ Proposed SHGC Target SHGC++ <br /> Provide source of SHGC, page/plan#of assembly PF SHGC* x Area(A)=SHGC x A PF SHGC x Area(A)= SHGC x A <br /> detail&ID Category <br /> ID: 0 PF<0.2 0.40 <br /> ID: 0 0.2:5PF<0.5 0.44 <br /> ID: 0 PF>_0.5 0.48 <br /> ID: 0 ++if projection factor(PF)credits are applied <br /> ID: 0 to the proposed design, Target SHGC will <br /> ID: 0 sum fenestration area by PF category. <br /> ID: 0 <br /> North Total <br /> Area I SHGC x AlArea I SHGC x A <br /> To comply, the Proposed total SHGC x A for all fenestration(vertical Grand Grand <br /> &skylights)shall not exceed the Target total SHGC x A. Total 7847.0 3127.0 Total 7847.0 3128.9 <br /> Component Performance Compliance (SHGC) SHGC COMPLIES <br /> i��/b <br />