Laserfiche WebLink
Frelf MJ Me <br /> 2015 Washington State Energy Code Compli rms for Commercial Buildings inclPing2,R3,R4 over 3 storieE Revised August 2016 <br /> Project Title: JDSTI Date 1/20/2017 <br /> Calculation d 0 Addition- , Addition For Building Department Use <br /> Area NOTE8 stand alone +existing <br /> al Spaces where<50%of b Spaces where>_50%of <br /> luminaires are replaced luminaires are replaced <br /> LPA 40 Standard a Additional Efficiency Package Option G <br /> Calculation 0406-3 Reduced Interior Lighting Power <br /> To comply with C406 3.the Proposed L PD shall be 25%lower than the Target LPA <br /> Type Refer to C406 3 for additional requirements <br /> Maximum Allowed Lighting Wattage NOTE 1 <br /> Location(plan#, Gross Interior Allowed Watts Allowed <br /> Building Area room#,or ALL) Area Description Area in f:2 Watts per f:2 (watts/f:2 x area) <br /> Office A2.1 Office Areas 2 714 0.66 17 92 <br /> Office A2.1 Restrooms 244 0.66 162 <br /> Manufacturing A21 Shop Area 5500 0.89 4895 <br /> facility <br /> Warehouse A2.1 open area 16542 0.40 6617 <br /> Total 25000 <br /> Proposed Lighting Wattage <br /> Location(plan#, Number of Wafts per <br /> Building Area room#) Fixture Description NOTE2,3,4,5 Fixtures Fixture NOTE6 Watts Proposed <br /> Office A2.1 2x4 Fluorescent 31 42 1302 <br /> Office A2.1 Downlights 12 9 108 <br /> Manufacturing A2.1 High Bay Lights 3 142 426 <br /> facility <br /> Warehouse A2.1 Strip Lights 4 41 164 <br /> Warehouse A2.1 High Bay Lights 8 142 1136 <br /> Compliance by Building Area NOTE' <br /> Total Allowed Total Proposed Interior Lighting <br /> Building Area Warnings Watts Watts Power Allowance <br /> Office 1954 1410 COMPLIES <br /> Manufacturing Confirm all fixtures are reported under proposed lighting-low watts 4895 426 COMPLIES <br /> facility relative to maximum allowed. <br /> Confirm all fixtures are reported under proposed lighting-low watts <br /> Warehouse 6617 1300 COMPLIES <br /> relative to maximum allowed. <br /> Note 1-List all unique building areas per Table C405.4.2(1)that occur in the Totalsl 134661:3136 <br /> project scope.Select building area category from drop down menu. <br /> Note 2-Proposed fixtures must be listed in the building area in which they occur.List all proposed lighting fixtures including exempt <br /> lighting equipment and existing-to-remain fixtures. <br /> Note 3-For proposed Fixture Description,indicate fixture type,lamp type(e.g.T-8),number of lamps in the fixture,and ballast type(if included). <br /> For track lighting,list the length of the track(in feet)in addition to the fixture,lamp,and ballast information. <br /> Note 4-Forlighting equipment eligible forexemption per C405.4.1,note exception numberand leave Watts/Fixture blank. <br /> Note 5-Existing-to-remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures.Identify as <br /> existing in fixture description. <br /> Note 6-For proposed WattsrFixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source.For <br /> luminaires with screw-in lamps,enter the manufacturer's listed maximum input wattage ofthe fixture(not the lamp wattage).For low voltage <br /> lighting,enter the wattage ofthe transformer.For line voltage track/busway systems,enter the larger ofthe attached luminaire wattage or <br /> 50 watts/lineal foot,or enter the wattage limit of permanent current limiting device. <br /> Note 7-Proposed Wattage for each Building Area type shall not exceed the Allowed Wattage for that Building Area type.Trading wattage <br /> between Building Area types is not allowed under the Building Area Method compliance path. <br /> Note 8-Calculation Area Details.- <br /> a. <br /> etails:a.Lighting fixtures in a building addition may comply as a stand alone project,or they may be combined with the overall existing building <br /> lighting systems to demonstrate compliance.Refer to C502.1. <br /> b.For alterations and building additions,provide Building Area types and gross interior areas in the Maximum Allowed Lighting Wattage <br /> table.If a building addition will comply as combined with the overall existing builidng lighting systems, include all applicable existing <br /> Building Area types and gross interior areas. <br /> c.If less than 50%of existing lighting fixtures will be replaced,Ti <br /> CE form to document compliance. <br /> � <br />