My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6201 ASSOCIATED BLVD JDS INC 2018-03-29
>
Address Records
>
ASSOCIATED BLVD
>
6201
>
JDS INC
>
6201 ASSOCIATED BLVD JDS INC 2018-03-29
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/29/2018 1:19:46 PM
Creation date
8/17/2017 8:51:15 AM
Metadata
Fields
Template:
Address Document
Street Name
ASSOCIATED BLVD
Street Number
6201
Tenant Name
JDS INC
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
128
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UH-3 thru 6 <br /> Page Number of <br /> REZHOR Power Vented, Low Static Axial Fan Unit Heaters <br /> ' for Residential and Commercial/Industrial Use <br /> Model UDAP Sizes 30-125 <br /> approved for utility applications <br /> ' such as residential garages <br /> under CSA International Requirement <br /> 0 10.96 - U.S. and CR96-0005 - Canada <br /> 1 Z <br /> F <br /> CSA 2.6b ANSI Z83.8b <br /> ' DESCRIPTION Reznor"V3 Series Model UDAP gas-fired unit heaters are available in 14 sizes ranging from 30,000 to 400,000 <br /> BTUH gas input.Sizes 30-125 are approved for residential application.All sizes are approved for commercial/ <br /> ' industrial installations. Model UDAP heaters are designed for 82-83%thermal efficiency and are approved for <br /> installation in the United States and Canada by the Canadian Standards Association(CSA). <br /> Reznor V3 Series unit heaters have a refreshing new appearance with a glossy white cabinet finish and less <br /> visible hardware. Each size cabinet is easily suspended from either 2 or 4 suspension points. Or,an optional <br /> ' hanger kit for Sizes 30-125 allows for ceiling mounting. The low voltage terminal strip on the outside of the <br /> cabinet makes connecting control wiring easy with no panels to remove.The addition of a"G"terminal to the <br /> strip, along with the new design of the circuit board, allows for fan only operation (without adding relays).All <br /> units have a factory installed gas line nipple to the exterior of the cabinet for easy gas service connection. <br /> ' The preeminent new internal feature is the TcoRE2®heat exchanger and single burner combustion system. <br /> Other standard features include a single-stage gas valve,multi-try direct spark ignition with 100%lockout,pres- <br /> sure switch to verify vent flow,resiliently isolated venter motor,venter wheel with improved housing,resiliently <br /> isolated axial fan and motor assembly,and a high temperature limit control.Sizes 30-125 also include a flame <br /> rollout safety switch. Operation is controlled through an integrated circuit board. The circuit board monitors <br /> ' heater operation and has LED diagnostic indicator lights to identify abnormalities in control functions. <br /> The V3 Series unit heaters are designed to provide all the features you expect in a Reznor heater plus im- <br /> proved efficiency,easier installation,and a new look—both inside and out.Look for the unique white unit with <br /> no visible front and bottom hardware,deep red louvers,black side handle,and angled corner to know you have <br /> ' a genuine Reznor unit by Thomas&Betts. <br /> STANDARD FEATURES • Sizes 30-125 certified for residential heating application <br /> • Sizes 30-400 certified for commercial/industrial heating application <br /> • 82-83%Thermal efficient—TOP in its class! <br /> • 50-60°F Rise range <br /> TcoRE21 titanium stabilized aluminized steel heat exchanger <br /> • Patented"TcoREz"single burner combustion system including a one-piece burner assembly <br /> • 115/1/60 Supply voltage <br /> ' • 115 Volt open fan motor with internal overload protection <br /> • Transformer for 24-volt controls <br /> • Integrated circuit board with diagnostic indicator lights <br /> • Multi-try direct spark ignition with 100%lockout <br /> ' • Fan relay(included on the circuit board) <br /> • Single-stage natural gas valve(field adjustable for operation to 9,000 ft.elevation) <br /> • Vibration/noise isolated fan and venter motors—designed for low noise operation <br /> • 2-pt and 4-pt Suspension—standard on all sizes <br /> • External terminal strip for 24-volt wiring <br /> ' • External gas connection <br /> • Full fan guard—engineered for safety <br /> • Improved cabinet design with less visible hardware and a NEW Reznor appearance <br /> OPTIONAL FEATURES - • Single-stage,propane gas valve(field adjustable for operation to 9,000 ft.elevation) <br /> ' FACTORY INSTALLED • Two-stage natural gas or propane gas valve-Sizes 60-400 <br /> • 409 or 316 Stainless steel heat exchangers <br /> • 208 or 230 Single phase voltage <br /> • Totally enclosed fan motor(Sizes 30-250, 115V only) <br /> ' • Common venting with other gravity vented Category I appliance(s)(Sizes 30-100) <br /> U.S.Patent No.6,889.686 <br /> ' Form RZ-C-UH(Version H)Page 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.