My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6201 ASSOCIATED BLVD JDS INC 2018-03-29
>
Address Records
>
ASSOCIATED BLVD
>
6201
>
JDS INC
>
6201 ASSOCIATED BLVD JDS INC 2018-03-29
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/29/2018 1:19:46 PM
Creation date
8/17/2017 8:51:15 AM
Metadata
Fields
Template:
Address Document
Street Name
ASSOCIATED BLVD
Street Number
6201
Tenant Name
JDS INC
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
128
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
InnovairFlex' Duct Smoke Detector Specifications <br /> Architectural/Engineering Specifications <br /> ' The air duct smoke detector shall be a system Sensor InnovairFlex"D4120 Photoelectric Duct Smoke Detector.The detector housing shall be UL listed per UL <br /> 268A specifically for use in air handling systems.The flexible housing of the duct smoke detector fits multiple footprints from square to rectangular.The detector <br /> shall operate at air velocities of 100 feet per minute to 4000 feet per minute(0.5 to 20.32 meters/second).The unit shall be capable of controlling up to 50 air <br /> handling systems when interconnected with other detectors.The detector shall be capable of providing a trouble signal in the event that the front cover is <br /> removed.It shall be capable of local testing via magnetic switch,test button on the cover,or remote testing using the SSK451 Multi-Signaling Accessory or the <br /> ' RTS451 KEY Remote Test Station.Termina I connections shall be of the strip and clamp method suitable for 12-18 AWG wiring. <br /> Physical Specifications <br /> Size:(Rectangular Dimensions) 14.38 in(37 cm)Length;5 in(12.74 cm)Width;2.5 in(6.36 cm)Depth <br /> ' (Square Dimensions) 7.75 in(19.7 cm)Length;9 in(22.9 cm)Width;2.5 in(6.35 cm)Depth <br /> Weight: 2.5 lbs(1.14 kg) <br /> Operating Temperature Range: D4120&D4S:-4°to 158°F(-20°to 70°C); D4P120:-40°to 158°F(-40°to 70°C) <br /> Storage Temperature Range: D4120&D4S:-22°to 158°F(-30°to 70°C); D413120:-40°to 158°F(-40°to 70°C) <br /> ' Operating Humidity Range: 0%to 95%relative humidity non-condensing <br /> Air Duct Velocity: 100 to 4000 ft/min(0.5 to 20.32 m/sec) <br /> Electrical Ratings <br /> Power supply voltage: 20-29 VDC 24 VAC 50-60 Hz 120 VAC 50-60 Hz <br /> ' Input capacitance: 270 pF max. 270 pF max. N/A <br /> Reset voltage: 3.0 VDC min. 2.0 VAC min. 10 VAC min. <br /> Reset time:(with RTS451) .03 to 0.3 sec. .03 to 0.3 sec. .03 to 0.3 sec. <br /> Reset time:(by power down) 0.6 sec.max. 0.6 sec.max. 0.6 sec.max. <br /> Power up time: 35 sec.max. 35 sec.max. 35 sec.max. <br /> Alarm response time: 15 sec. 15 sec. 15 sec. <br /> Sensitivity Test: See detector label See detector label See detector label <br /> ' Current Requirements:(Using No Accessories) <br /> Max.standby current: 21 mA @ 24VDC 65 mA RMS @ 24VAC 60Hz 20 mA RMS @ 120VAC 60Hz <br /> Max.alarm current: 65 mA @ 24VDC 135 mA RMS @ 24VAC 60Hz 35 mA RMS @ 120VAC 60Hz <br /> Contact Ratings <br /> ' Alarm initiation contacts:(SPST) 2.OA @ 30 VDC(resistive) <br /> Alarm auxiliary contacts:(DPDT) I OA @ 30 VDC(resistive);10A @ 250 VAC(resistive);1/2 HP @ 240 VAC;y4 HP @ 120 VAC <br /> ' Note:Alarm auxiliary contacts shall not be connected to initiating circuits of control panels.Use the alarm initiation contact for this purpose. <br /> Supervisory contacts:(SPDT) 2.OA @ 30 VDC(resistive);2.OA @ 125 VAC(resistive) <br /> Accessory Current Loads at 24 VDC <br /> Device Standby Trouble Alarm <br /> ' <br /> APA 15 1/APA4 51 12.5 mA n/a 30 mA Max. <br /> MHR/MHW 0 mA n/a 29 mA Max. <br /> RAI OOZ 0 mA n/a 12 mA Max. <br /> RTS151/RTS151 KEY 0 mA/12 mA n/a 12 mA Max. <br /> ' RTS2/RTS2-AOS 3.OmA max 16 mA Max. with strobe:55 mA max,without strobe 30 mA max <br /> Note:Any combination of accessories may be used such that the given accessory loads are:110 mA or less at the Aux output,and 50 mA or less at the Alarm output <br /> ' Installing the InnovairFlex Sampling Tube <br /> The InnovairFlex sampling tube may be installed from the front or back of the detector.The tube locks securely into place and can be removed by releasing <br /> the front or rear locking tab(front locking tab shown below right). <br /> �nM <br /> A05-0919-OOI <br />
The URL can be used to link to this page
Your browser does not support the video tag.