Laserfiche WebLink
Prestige jag :3 ) <br /> Y01K Single Package R-41 OA Air Conditioner <br /> Project Name: OUR SAVIORS LUTHERN CHURCH-EVERETT-REV-1 Unit Model#: ZXG12E2B3AA1A111A2 <br /> Quantity: 2 Tag#:5-6 WKS-FACTORY System: ZXG12E2B3AA1A111A2(2) <br /> BLD <br /> Cooling Performance <br /> Total capacity 133.0 MBH <br /> Sensible capacity 93.0 MBH <br /> Refrigerant type R-41 OA <br /> Efficiency(at ARI) 11.00 EER _ <br /> Integrated eff.(at ARI) 14.40 IEER <br /> Ambient DB temp. 95.0 °F <br /> Entering DB temp. 80.0 °F <br /> Entering WB temp. 67.0 •F <br /> Leaving DB temp. 58.5 •F <br /> Leaving WB temp. 56.5 °F =_ <br /> Power input(w/o blower) 9.21 kW <br /> Sound power 84 dB(A) <br /> Gas Heating Performance <br /> Entering DB temp. 60 °F - <br /> Heating output capacity(Max) 176 MBH <br /> Supply air 4000 CFM <br /> Heating input capacity(Max) 220 MBH <br /> Leaving DB temp. 100.7 °F <br /> Air temp.rise 40.7 °F 10 Ton <br /> SSE 80.0 % . All units are manufactured at an ISO 9001 registered facility and each <br /> Stages Supply Air Blower Performance 2 rooftop is completely computer-run tested prior to shipment. <br /> Supply air 4000 CFM Unit Features <br /> Ext.static pressure 0.8 IWG • Unit Cabinet Constructed of Powder Painted Steel,Certified At 1000 Hours <br /> Add].Unit Losses(Options/Accessories) 0.17 IWG Salt Spray Test(ASTM B-117 Standards) <br /> Blower speed 906 RPM • Either supply and/or return can be field converted from vertical to horizontal <br /> Max BHP of Motor(including service factor) 3.70 HP configuration without cutting panels. <br /> Duct location Side <br /> Actual required BHP 2.58 HP Full perimeter base rails with built in rigging capabilities <br /> Power input 2.30 kW • Scroll Compressors <br /> Elevation 0 ft. • Solid Core Liquid Line Filter Driers <br /> Drive type BELT • Microchannel Condenser Coil <br /> Outside/Mixed Air • 220 Mbh Two Stage Input Medium Heat Aluminized Gas <br /> Outside Air Cfm 1100 CFM • Medium Static Belt Drive Blower <br /> • Unit Ships with 2"Throwaway Filters with a Standard Filter Rack that will <br /> Electrical Data Accept up to 4"Filters <br /> Power supply 230-3-60 • Replacement Filters:4-(20"x 20").Unit accepts 2"wide filter. <br /> Unit min circuit ampacity 49.6 Amps • Single Point Power Connection <br /> Unit min over-current protection 50 Amps • Short Circuit Current:5kA RMS Symmetrical <br /> Unit max over-current protection 60 Amps <br /> Dimensions&Wei ht Standard Unit Controller: Simplicity SE Control Board <br /> Hgt 49 in. Len 87 in. t 62 in. An Integrated Low-Ambient Control,Anti-Short Cycle Protection,Lead-Lag, <br /> Weight with factory installed options 995 Ins. Fan On and Fan off Delays,Low Voltage Protection,On-Board Diagnostic <br /> Clearances and Fault Code Display.Allows all units to operate in the cooling mode down <br /> to 0"F outdoor ambient without additional components or intervention. <br /> Right 18 in. Front 48 in. Back 18 in. Safety Monitoring-Monitors the high and low-pressure switches,the <br /> Top 72 in. Bottom 1 in. Left 12 in. j freezestats,the gas valve,if applicable,and the temperature limit switch on <br /> Note: Please refer to the tech guide for listed maximum static pressures gas and electric heat units.The unit control board will alarm on ignition <br /> failures,safety lockouts and repeated limit switch trips. <br /> BAS Controller <br /> 4064mmV., <br /> • Simplicity SE Controller with Discharge Air, Return Air,and Outside Air <br /> Sensor <br /> Warranty <br /> • One(1)Year Limited Warranty on the Complete Unit <br /> • Five(5)Year Warranty-Compressors <br /> • Ten(10)Year Warranty-Aluminized Steel Tubular Heat Exchangers <br />