My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
215 W MUKILTEO BLVD 2017-08-24
>
Address Records
>
W MUKILTEO BLVD
>
215
>
215 W MUKILTEO BLVD 2017-08-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2017 11:31:38 AM
Creation date
8/24/2017 11:31:09 AM
Metadata
Fields
Template:
Address Document
Street Name
W MUKILTEO BLVD
Street Number
215
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
138
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WYORK <br /> Guide Specification for Page: 13 , <br /> Prestige <br /> b. High pressure switch shall use different color wire than the low pressure switch.The purpose is to assist the <br /> installer and service technician to correctly wire and or troubleshoot the rooftop unit. <br /> 4. Automatic reset,/motor thermal overload protector. <br /> 5. Heating section shall be provided with the following minimum protections: <br /> a. High-temperature limit switches. <br /> b. Induced draft motor speed sensor. <br /> c. Flame rollout switch. <br /> d. Flame proving controls <br /> 23 09 93 Sequence of Operations for HVAC Controls <br /> 23 09 93. 13 Decentralized, Rooftop Units <br /> 23 09 93. 13 INSERT SEQUENCE OF OPERATION <br /> 23 40 13 Panel Air Filters <br /> 23 40 13. 13 Decentralized, Rooftop Units <br /> 23 40 13. 13.A Standard filter section <br /> 1. Shall consist of factory-installed, low velocity,disposable 2"thick fiberglass filters of commercially available sizes. <br /> 2. Units can accept 2"or 4"filters and have a field convertible toolless <br /> 3. Filters shall be accessible through an access panel with toolless removal as described in the unit cabinet section of this <br /> specification (23 81 19.13.1-1). <br /> 23 81 19 Self-Contained Air Conditioners <br /> 23 81 19. 13 Small-Capacity Self-Contained Air Conditioners <br /> 23 81 19. 13.A General <br /> 1. Outdoor, rooftop mounted, electrically controlled, heating and cooling unit utilizing a fully hermetic scroll compressor(s) <br /> for cooling dutyand gas combustion for heating duty. <br /> 2. Factory assembled,single-piece heating and cooling rooftop unit.Contained within the unit enclosure shall be all <br /> factory wiring, piping, controls, and special features required prior to field start-up. <br /> 3. Unit shall use environmentally sound, R-41 OA refrigerant. <br /> 4. Unit shall be installed in accordance with the manufacturer's instructions. <br /> 5. Unit must be selected and installed in compliance with local,state,and federal codes. <br /> 23 81 19. 13.8 Quality Assurance <br /> 1. Unit meets ASHRAE 90.1 minimum efficiency requirements. <br /> 3. Unit shall be rated in accordance with AHRI Standards 210/240 and 340/360. <br /> 4. Unit shall be designed to conform to ASHRAE 15,2001. <br /> 5. Unit shall be UL-tested and certified in accordance with ANSI Z21.47 Standards and UL-listed and certified under <br /> Canadian standards as a total package for safety requirements. <br /> 6. Insulation and adhesive shall meet NFPA 90A requirements for flame spread and smoke generation. <br /> 7. Unit casing shall be capable of withstanding 1000-hour salt spray exposure per ASTM 13117(scribed specimen). <br /> 8. Unit shall be designed in accordance with ISO 9001,and shall be manufactured in a facility registered by; ISO 9001. <br /> 9. Roof curb shall be designed to conform to NRCA Standards. <br /> 10. Unit shall be subjected to a completely automated run test on the assembly line.The data for each unit;will be stored <br /> at the factory, and must be available upon request. <br /> 11. Unit shall be designed in accordance with UL Standard 1995, including tested to withstand rain. <br /> 12. Unit shake tested to assurance level 1,ASTM D4169 to ensure shipping reliability. <br /> 13. High Efficient Motors listed shall meet section 313 of the Energy Independence and Security Act of 2007; (EISA 2007). <br />
The URL can be used to link to this page
Your browser does not support the video tag.