�/ Page 1 of 1 <br /> MAI ;ES TEST/NG ENGINEER.3,INC. <br /> Ultrasonic Examination Report <br /> 20225 Cedar Valley Road,Suite P 425.742.9360 <br /> 110 Lynnwood,WA 98036 F 425.745.1-737 <br /> 10029 S.Tacoma Way,Suite P 253.584.3720 Project No.: L16176 Date: 04/06/16 <br /> E-2 Tacoma,WA 98499 F 253.584.3707 <br /> 7911 NE 33rd Drive,Suite 190 Project: Our Saviors Lutheran Church <br /> Portland,OR 97211 P 503.281.T515 <br /> F 503.281.7579 <br /> Specification: AWS D1.1 Weld Process: O SMAW OO FCAW O GMAW O SAW <br /> UT Equipment: Long. Transducer: Shear Transducer: Calibration Block: <br /> IIW 0 DSC <br /> Model USM Gopls Freq.: 2.25 Freq.: 2.25MHZ <br /> Serial No. GOPLS13100050 Size: 1" Size: .625 X .625 Other. <br /> Decibels Discontinuity <br /> > m > E <br /> m > d <br /> Q O O O <br /> o a u <br /> c Q Sound Distance v <br /> Location Weld a I b c I d 1 Path Length Depth X Y q Remarks <br /> Column 3 <br /> R1 CJP 4 70 54 X Bottom flange(north side) <br /> Column 2 <br /> R1 CJP 1 70 54 X Top flange(north side) <br /> Column 2 <br /> R1 CJP 2 70 54 X Bottom flange(south side) <br /> Column 2 <br /> R1 CJP 3 70 54 X Top flange (south side) <br /> Inspector: Tim York Level: II <br /> �I s MTE 1521-2C,Rev 2,8/01/14 <br />