My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7809 19TH DR SE 2017-08-25
>
Address Records
>
19TH DR SE
>
7809
>
7809 19TH DR SE 2017-08-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/25/2017 3:51:15 PM
Creation date
8/25/2017 3:50:59 PM
Metadata
Fields
Template:
Address Document
Street Name
19TH DR SE
Street Number
7809
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
69
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Simple Heating System Size: Washington State <br /> This heating system sizing calculator is based on the Prescriptive Requirements of the 2012 Washington State Energy Code(WSEC)and ACCA Manuals <br /> J and S.This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling loads. <br /> The glazing(window)and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of 0.30. <br /> The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2012 WSEC. <br /> Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section,some <br /> values will be calculated for you. If you do not see the selection you need in the drop-down options, please call the WSU Energy Extension Program at <br /> (360)956-2042 for assistance. <br /> Project Information Contact Information <br /> Plan 2407 <br /> Heating System Type: O All Other systems 0 Heat Pump <br /> To see detailed instructions for each section,place your cursor on the word'Instructions". <br /> Design Temperature <br /> Instructions Design Temperature Difference(AT) 49 <br /> Everett Paine AFB �)� AT=Indoor(70 degrees)-Outdoor Design Temp <br /> Area of Building <br /> Conditioned Floor Area <br /> Instructions Conditioned Floor Area(sq ft) 2,407 <br /> Average Ceiling Height Conditioned Volume <br /> Instructions Average Ceiling Height(ft) 8.5 20,460 <br /> Glazing and Doors U-Factor X Area = UA <br /> Instructions <br /> 0.30 448 134.40 <br /> Skylights U-Factor X Area = UA <br /> 0 Instructions 0.50 --- <br /> Insulation <br /> Attic U-Factor X Area = UA <br /> Instructions 0.026 1,120 29.12 <br /> Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA <br /> Instructions - - - - - -- -----""- —_ <br /> 3:t�R-38 Vented � 0.027 <br /> Above Grade Walls(see Figure 1) U-Factor X Area UA <br /> Instructions -� - 0.056 2,700 151.20 R-21 Intermediate � <br /> Floors U-Factor X Area UA <br /> Instructions —` 0.029 590 17.11 <br /> R-30 ---- <br /> Below Grade Walls(see Figure 1) U-Factor X Area UA <br /> Instructions drs�No Below Grade Walls in this project. --- 500 <br /> Slab Below Grade(see Fiore 1) F-Factor X Len th <br /> UA <br /> Instructions <br /> Select conditioning No selection --- <br /> Slab on Grade(see Figure 1) F-Factor X Length UA <br /> Instructions 0.540 136 73.44 <br /> �R-SO Perimeter � <br /> Location of Ducts <br /> Instructions I Duct Leakage Coefficient <br /> No Ducts <br /> 1.00 <br /> Sum of UA 405.27 <br /> Envelope Heat Load 19,858 Btu/Hour <br /> Figure 1. Sum of UAX 1T <br /> Air Leakage Heat Load 10,827 Btu/Hour <br /> VolumeX 0.6XArx.01a <br /> Above Grade Building Design Heat Load 30,685 Btu I Hour <br /> Air Leakage f Envelope Heat Loss <br /> Building and Duct Heat Load 30,685 Btu/Hour <br /> Ducts in unconditioned space:Sum of Building Heat Loss X 1.10 <br /> Ducts in conditioned space:Sum of Building Heat Loss X 1 <br /> Maximum Heat Equipment Output 42,960 Btu/Hour <br /> Building and Duct Heat Loss X 1.40 for Forced Air Furnace <br /> Building and Duct Heat Loss X 1:25 for Heal Pump <br /> j <br /> tel¢ f (07/01/13) <br />
The URL can be used to link to this page
Your browser does not support the video tag.