My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2608 23RD ST 2017-08-25
>
Address Records
>
23RD ST
>
2608
>
2608 23RD ST 2017-08-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/25/2017 4:00:25 PM
Creation date
8/25/2017 4:00:19 PM
Metadata
Fields
Template:
Address Document
Street Name
23RD ST
Street Number
2608
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
BUILDING PLANNING <br /> SECTMN R310 required to comply with Sections R311.7 and R311.8. <br /> EMERGENCY ESCAPE AND RESCUE OPENINGS Ladders or rungs shall have an inside width of not less <br /> 8310.1 Emergency escape and rescue opening required. than 12 inches (305 mm), shall project not less than 3 <br /> Basements, habitable attics and every sleeping room shall inches (76 mm) from the wall and shall be spaced not <br /> havenot less than one operable emergency escape and rescue more than 18 inches (457 mm) on center vertically for <br /> opening. Where basements contain one or more sleeping the full height of the window well. <br /> rooms, an emergency escape and rescue opening shall be R310.2.3.2 Drainage.Window wells shall be designed <br /> required in each sleeping room. Emergency escape and res- for proper drainage by connecting to the building's <br /> cue openings shall open directly into a public way, or to a foundation drainage system required by Section R405.1 <br /> yard or court that opens to a public way. or by an approved alternative method. <br /> Exception: Storm shelters and basements used only to Exception: A drainage system for window wells is <br /> house mechanical equipment not exceeding a total floor not required where the foundation is on well-drained <br /> area of 200 square feet(18.58 m2). soil or sand-gravel mixture soils in accordance with <br /> 11310.1.1 Operational constraints and opening control the United Soil Classification System,Group I Soils, <br /> devices. Emergency escape and rescue openings shall be as detailed in Table R405.1. <br /> operational from the inside of the room without the use of R310.2.4 Emergency escape and rescue openings under <br /> keys,tools or special knowledge.Window opening control decks and porches. Emergency escape and rescue open- <br /> devices complying with ASTM F 2090 shall be permitted ings shall be permitted to be installed under decks and <br /> for use on windows serving as a required emergency porches provided that the location of the deck allows the <br /> escape and rescue opening. emergency escape and rescue openings to be fully opened <br /> R310.2 Emergency escape and rescue openings.Emergency and provides a path not less than 36 inches (914 mm) in <br /> escape and rescue openings shall have minimum dimensions height to a yard or court. <br /> as specified in this section. R310.3 Emergency escape and rescue doors.Where a door <br /> 11310.2.1 Minimum opening area. Emergency and is provided as the required emergency escape and rescue <br /> escape rescue openings shall have a net clear opening of opening, it shall be permitted to be a side-hinged door or a <br /> not less than 5.7 square feet (0.530 mZ). The net clear slider.Where the opening is below the adjacent ground eleva- <br /> opening dimensions required by this section shall be <br /> tion,it shall be provided with a bulkhead enclosure. <br /> obtained by the normal operation of the emergency escape R310.3.1 Minimum door opening size. The minimum <br /> and rescue opening from the inside. The net clear height net clear height opening for any door that serves as an <br /> opening shall be not less than 24 inches(610 mm)and the emergency and escape rescue opening shall be in accor- <br /> net clear width shall be not less than 20 inches(508 mm). dance with Section R310.2.1. <br /> Exception: Grade floor or below grade openings shall 11310.3.2 Bulkhead enclosures. Bulkhead enclosures <br /> have a net clear opening of not less than 5 square feet shall provide direct access from the basement. The bulk- <br /> (0.465 m). head enclosure shall provide the minimum net clear open- <br /> R310.2.2 Window sill height. Where a window is pro- ing equal to the door in the fully open position. <br /> vided as the emergency escape and rescue opening,it shall R310.3.2.1 Drainage. Bulkhead enclosures shall be <br /> have a sill height of not more than 44 inches (1118 mm) designed for proper drainage by connecting to the <br /> above the floor; where the sill height is below grade, it building's foundation drainage system required by Sec- <br /> shall be provided with a window well in accordance with tion R405.1 or by an approved alternative method. <br /> Section R310.2.3. Exception: A drainage system for bulkhead enclo- <br /> 11310.2.3 Window wells. The horizontal area of the win- sures is not required where the foundation is on <br /> dow well shall be not less than 9 square feet(0.9 in),with well-drained soil or sand-gravel mixture soils in <br /> a horizontal projection and width of not less than 36 inches accordance with the United Soil Classification Sys- <br /> (914 mm). The area of the window well shall allow the tem,Group I Soils,as detailed in Table R405.1. <br /> emergency escape and rescue opening to be fully opened. 81310.4 Bars,grilles,covers and screens.Bars,grilles,cov- <br /> Exception: The ladder or steps required by Section ers,screens or similar devices are permitted to be placed over <br /> R310.2.3.1 shall be permitted to encroach not more emergency escape and rescue openings,bulkhead enclosures, <br /> than 6 inches(152 mm)into the required dimensions of or window wells that serve such openings, provided that the <br /> the window well. minimum net clear opening size complies with Sections <br /> R310.2.3.1 Ladder and steps. Window wells with a R310.1.1 to R310.2.3,and such devices shall be releasable or <br /> vertical depth greater than 44 inches (1118 mm) shall removable from the inside without the use of a key,tool,spe- <br /> be equipped with a permanently affixed ladder or steps cial knowledge or force greater than that required for the nor- <br /> usable with the window in the fully open position.Lad- mal operation of the escape and rescue opening. <br /> ders or steps required by this section shall not be <br /> 62 2015 INTERNATIONAL RESIDENTIAL CODE° <br />
The URL can be used to link to this page
Your browser does not support the video tag.