My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1001 W CASINO RD BASE FILE 2018-01-01 MF Import
>
Address Records
>
W CASINO RD
>
1001
>
BASE FILE
>
1001 W CASINO RD BASE FILE 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2019 1:59:18 PM
Creation date
8/28/2017 3:37:25 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
1001
Tenant Name
BASE FILE
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
833
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�ublic right-of-way. Public Works Department approval of these <br /> drawings is required prior to any permits being issued. All <br /> impcovements shall be completed, appcoved, and warranted before the <br /> Occvpancy Permit is issued. (SEPA Other Policies) <br /> 2. (i) Fire flow requireme�ts: The Uniform Building Code, 1988 edition, <br /> requires that all apartment houses of 3 stocies or more, or <br /> containing 16 or more dwelling units be provided an automatic <br /> spcinkler system installed in compliance with NFPA Standard 13R. <br /> In compliance to this requicement, Buildings 1, 4, 5, 6, 7, and 8 <br /> of the SEPA site plan reviewed will be cequired to be spri�klec <br /> and the fire flow for each of these buildings is 1,500 GPM. <br /> Buildinga 2 and 3 are two stocy with less than 16 dwelling unita <br /> and are not required to be sprinklered, although are highly <br /> cecortmended. If these two buildinga are not sprinklered, the <br /> fire flow requirement will consist as follows: <br /> (A) For Ty�e 5-N construction, 2,750 GPM will be required, or <br /> (B) For Tyt:e 5 1 Houc construction, 1,750 GPM will be required, <br /> (ii) A fire hydrant is required within 200 driving feet of all <br /> building having a fire flow [equirement of 1,750 GPM or lesa. If <br /> option A above is exercised foc Buildings 2 and 3, three fire <br /> hydrants are required to be available within 200 driving feet of <br /> each of those �uildings. However, if Buildinga 2 and 3 are <br /> sprinklered or built to Type 5-1 Hour construction, three (3 ) <br /> fire hydrants will be required for the entire project. Location <br /> will be contingent to the Fire Marshal's approval. <br /> (iii) Sprinkler system is required in all but Buildinga 2 and 3. <br /> (iv) Fire alarm system shall be provide as required in Article 14 of <br /> the Uniform Fire Code, 1988 edition. <br /> (v) Portable Fire Protection - a minimum UL rated 2A.10 B.C, portable <br /> fire extinguisher must be provided within 75 feet travel distance <br /> of all combustible construction, also within 75 feet travel <br /> distance of all apartments prior to occupancy. (S['�PA Public <br /> Services and Utilities Policiea) <br /> 3. Full standard street improvements are required to llth Street including <br /> but not limited to curb, gutter, sidewalk, street widening with <br /> transition per City Deaign Standards for a street 18 feet from <br /> centerline to face of curb. (SEPA T�ansportation Policies) <br /> 4. Special charges for connection to the sewer and water systems in <br /> acoordance witt� Ordlnance 1171-85 ace applicable, The actual coat <br /> shall be computed by the Building Department per the Ordinance in <br /> eEfect at the t'vne and according to the info[mation pcovided on the <br /> app[oved plans on the date of permit issuance, (SEPA Public Services <br /> and Utilities Policies) <br /> - Z - <br />
The URL can be used to link to this page
Your browser does not support the video tag.