STRUCTURAL NOTES <br /> Code WALL BRACIC PANEL SCHEDULE <br /> 2012 IN1QNP11or � ZyIYJGNfIPt God Face nail double top plate with 1-10J at ZR' O.C. and lap minimum <br /> 2:-0" at joints and provide 6-16d 4' O.C. each side of joint. Face A. Plywootl /OSB 6d nail 6' 0.C. (edges) <br /> nail bottom plate.to wood below with 1 16d at 1fo O.C. Bolt bottom 3/8' x 4' x 8' 12' O.C. (field) <br /> Loads plate to-concrete below with 1/2' diameter at(P`0'O.C.with a bolt <br /> within 12" of ends of plate. Provide full blocking for columns B. GWB- 1/2' x 8' x 8' Sd cooler /wallboard nails <br /> Roof 25 PSF LL 15 PSF DL through floors to supports below. All Interior partitions sheathed (One face) •7'O.C. <br /> Floor 40 PSF LL 10 PSF DL with 1/2" gypsum wallboard are to be nailed with 5d cooler nails <br /> Deck 60 PSF LL 10 PSF DL at 7' O.C. to framed panel edges and Intermediate supports. Refer C. GMB- 1/2' x 4' x 8' Sd cooler /wallboard nails <br /> Basic wind Speed 051PH to architectural drawings for size and location of vents and (Two faces) •7'O.C. throughout <br /> Seismic Zone p 2 skylights and roof slopes. Nailing not otherwise called shall be <br /> in accordance with IR(,Nailing Schedule, Table D. Structural Panel Siding Corrosion-resisitant 6d nails <br /> Foundation and Slab-on-Grade 3/8' x 4' x 8' • 6' O.C. (edges) <br /> Footings to bear on undisturbed earth or structural fill of 15Gt�-PSH(assumed Trusses •12' O.C. (field) <br /> minimum bearing capacity at minimum depth below adjacent exterior grade Pre-manufactured trusses to be designed for loads and conditions E. One-story alt. brace panel Nailing 8d • 6"O.C. (edges) <br /> of 1'-6'. Foundation backfill shall be well-compacted, clean granular shown on these drawings antl in accordance with the specifications 3/8" x 2'-8' x 10' or less •12"O.C. (field) <br /> fill, containing no more than 51 by weight of fines (passing no. 200 of the manufacturer. Design, fabrication and erection shall conform Blocking required at all edges. <br /> slave) and should be compacted in maximum 8' loose thickness lifts to to the latest standards of the manufacturer and the IP-6 )Zyjo2.l,?. Anchor bolts - (2) placed at <br /> at least 95%of maximum dry density at optimum moisture content as Design shall be stamped and signed quarter points. <br /> determined by ASTM D-1557. Soll beneath slab-on-grade shall be by a structural engineer licensed In the State of Washington. Holdowns - 1800"at each end, <br /> compacted to at least 90%of maximum dry density at optimum moisture Trusses shall have adequate bridging and blocking as required. Submit <br /> content as determined by ASTM D 1557. Backfill behind all walls with shop drawings with calculations to the Owner and permitting agency for F. Two story alt. brace panel Nailing 8d• "O.C. ledges) <br /> wall draining, granular fill material, and provide for sub-surface review prior to fabrication. 3/8" x 2'-8" x 10' or less •12"O.C. (field) <br /> drainage. All footings to center below centerline of columns or walls Plywood or OSB (Two faces) Blocking required at all edges. <br /> above. Place 4' slab-on-grade over 6 mil (black) vapor barrier over General Anchor bolts - (3) placed at <br /> 4" compacted gravel. Reinforce slab with 6x6 W1.4 x W1.4, centered. fifth points. <br /> °rovide construction or control joints in slabs-on-grade to break up Contractor shall verify all dimensions and conditions before Holdowns - 3000"at each end. <br /> slab Into rectangular areas not to exceed 400 SF or 20 feet in any proceeding with the work. Any variations from these drawings shall be <br /> direction. Joint locations shall be approved by the Owner. brought to the attention of the Owner. The Contractor is responsible General Notes: <br /> for erection stability and temporary shoring as necessary until <br /> Concrete permanent support and stiffening are installed. 1. Braced wall panel sole plates nailed to floor and top plates shall be anchored <br /> to framing above. <br /> All concrete to be mixed, proportioned, conveyed and placed in - Any proposed field changes must have written approval from the Owner. 2. Where joists are perpendicular to braced wall lines, provide blocking under and <br /> accordance with Section 94o1,2of the ffw and the American Concrete Contractor-Initiated changes shall be submitted In writing to the and in line with braced wall panels. <br /> Institute's Specification for Structural Steel Concrete for Buildings Owner for approval prior to fabrication or construction. <br /> (ACI 301). F'c - 2500 PSI at 28 days. Concrete cover on reinforcing <br /> steel shall be as follows: - <br /> Concrete cast against &permanently exposed to earth 3" ENERGY NOTES <br /> Concrete exposed to the earth or weather 1 1/2' -. - <br /> Concrete not exposed to the earth or weather 3/4' <br /> General Provisions; <br /> Embed anchor bolts a minimum of 7' Into concrete and hook. Provide 5Y 1. Mechanical sot exhaust ventilation, tlucttl to the exterior, is <br /> air entrainment in all concrete subject to freezing after curing. All p <br /> concrete shall poured monolithically unless shown otherwise. required in all bathrooms (50CFM) and kitchens (100CFM)anrA laundry roonvs C50--A) <br /> Backdraftdampers are required. J->p� R012. Wa li <br /> Reinforcing Steel 2. Outside air is required to be supplied into the conditioned <br /> space. See ventilation requirements. <br /> Reinforcing steel shall be deformed billet steel conforming to ASTM 3. All structural softwood plywood, particleboard, waferboard and <br /> A615, grade 40, Fy - 40,000 PSI. Unless otherwise noted, lengths of oriented strand boards "Exposure I' or "Exterior". <br /> laps shall be 26' and embedment shall be 15'. 4. Water heater storage tanks labeled as meeting ASHIAE standard <br /> 90A- 1980 or insulated to R-16. <br /> Provide elbow bars to lap horizontal bars at corners and 5. Water heater storage tank must be placed on an R-10 pad if <br /> intersections. All hooks shall be 'standard' in accordance with ACI located over uninsulated or concrete floors. <br /> 318. Welded wire fabric (WWF) shall be cold-drawn wire conforming 6. Insulate hot and cold water pipes to R-3 in unheated areas. <br /> ASTM A-185, Fyy -60,000 PSI. Supply in sheets, no rolls. Lap welded 7. Shower regulations to limit hot water discharge to 675 GPA). <br /> wire fabric 12splices. Reinforce around wall openings greater than 8• Heating ducts must be insulated to R-11. <br /> 16" in either direction with 2-'S each side full-height. 2-"5 top and 9• Woodstoves and fireplaces have tightfitting doors. <br /> bottom and 1-15 x 4'-0" diagonal at each corner. Extend bars 2'-0" 10. Woodstoves and fireplaces have outside combustion air ducted <br /> beyond opening. If 2'-0" is not available, extend as far as possible to the ftrebox, with an accessible damper. (Min. 6 sq. in. <br /> and hook. Hook tops and bottoms of all vertical reinforcing net free vent area) <br /> Interrupted by openings. Anchor Dolts to conform to ASTM A307. 11. Fireplaces have tight-fitting flue dampers. <br /> 12. All gas or off combustion appliances have direct vent or <br /> Timber Connections forced draft venting. <br /> 13. Recessedlights are I.C. rated, double wall can lights. <br /> Connectors called out by letters and numbers shall be "Strong-Tie" by 14. 6 mil (black) vIsqueen ground cover in drawl space. <br /> Simpson Company, as specified in their latest catalog, or approved AIR SEALING <br /> equal. Provide number and size of fasteners as specified by <br /> manufacturer. Connectors are to be Installed in accordance with 1. All,plumbing. electrical and HVAC penetrations In floors, <br /> manufacturer's recommendations. Where connector straps connect two p e <br /> members, place one-half of the nails or bolts in each member. All nails walls and ceilings are caulked and sealed. <br /> to be common. All shims shall be seasoned and dried and the same grade 2• Where penetrations need a fire stop, discuss with your <br /> (minimum) as members connected. All joists are to be connected to flush building department. <br /> beams with LU series joist hangers. All double-jolst beams are to be 3. Electrical outlet and light switch boxes on exterior walls <br /> connected to flush beams with Hi1210-2. All triple-joist beams are to must be sealed at the back of the receptacle or sealed with <br /> be connected to flush beams with H#1210-37. faceplate gaskets. <br /> 4. Seal rim joist between heated floor or use a product like <br /> Lumber "Tyvek"on exterior. <br /> MAPA rt!d) 5. Vapor barrier may be either face stapled batts, 4 mil <br /> All lumber is to be in accordance with WWPA�grading rules. Lumber to visqueen or a vapor barrier paint. <br /> be Doug-Fir (KD 15), unless noted otherwise. Light framing to be INSLLATION: <br /> Hem-Fir. <br /> Roof sheathing shall be 1/2'COX plywood with exterior glue (ppanel 1. Faced batts are lapped and face stapled at framing members. <br /> Index 24/0), or 7/16'OSB. Floor sheathing shall De 3/4"C-D T&G(,^ aced) 2. All exterior wall cavities are filled with uncompressed <br /> plywood with exterior glue (panel Index 36116) or 3/4' T&G OSB. Wall insulation, including all cavities isolated during framing. <br /> sheathing shall be 1/2" C-D plywood with exter for glue (panel Index Miring and plumbing do not compress Insulation. <br /> 24/0) or 7/16'OSB. All lumber in contact with concrete or masonry 3. All recesses fixtures in exterior walls have rigid board <br /> shall be pressure-treated. Insulation behind them. <br /> 4. Underfloor insulation is supported by lath, twine or other <br /> Glue-Laminated Timber non-compressing means. <br /> 5. Attic access door is baffled, weatherstripped and insulated. <br /> Doug-Fir, Fb -2400 PSI, conforming to AITC Standard 117. Simple NON-HEAT RECOVERY VENTILATION <br /> span beams .shall be combination 24F-V3. Provide minimum camber for <br /> simple span beams per fabricator's recommendations. 1. Whole house ventilation fan is capable of exhausting 16 CFM <br /> Framing from each bedroom and 15 CFM from each combined living area <br /> (CFM rating- 15 x number of bedrooms 1). <br /> Plywood roof and floor sheathing shall be laid up with face grain 2. Whole house ventilation fan has both automatic (timer clock <br /> perpendicular to supports and nailed with 8d . at 6" or dehumidistat) AND manual controls. <br /> O.C. to framed panel edges and at 12'O.C. (12"O.C. at roof) to 3. The whole house exhaust fan has a sone rating <-1.5 or is <br /> Intermediate supports. Provide full-depth blocking at lines of remotely located from conditioned space. <br /> olst slpports. At blocked floor and roof diaphragms provide flat 4. All exhaust fans or exhaust ducts have tight-fitting <br /> �x blocking at all unframed plywood panel edges and nail with edge backdraft dampers. <br /> nailing specified. Toenail each joist to top plate or beam below 5. Exhaust ductwork is sized according to plans and is <br /> with 3:$d nails. Provide double joists under parallel partitions insulated in unheated spaces. <br /> above (extending over 1/2 the length of the joist). All columns 6. Each bedroom and combined living area has a through-the-wall <br /> shall be two studs minimum. All non-bearing walls shall be 2x4 port or central ducted vent capable of providing 15 CFM of <br /> studs at 16' O.C. minimum. Walls shall have a single bottom plate outside air. <br /> and a double top plate. End nail top plate to each stud with 2-16d 7• Air intake ports are located away from potential sources of <br /> nails, and toenail or end nail each stud to bottom plate with 2-16d air or noise pollution, and have adequate bird and bug <br /> Nail multi-stud columns and multi-joist beams with 1-16d at 12'O.C. screens. <br /> 8. Air Intake source has provision for flow control to limit <br /> excessive air flow under normal operation. aav� <br />
The URL can be used to link to this page
Your browser does not support the video tag.