Laserfiche WebLink
00 <br /> Project Name: Everett River Front-Simpson Report: 106 <br /> GeoDesign#: Polygon-127-01 _..._ _.., ... _�__.. .__..._ _ Date: 8/11/2016 <br /> Reports with Unresolved Nonconformance Issues: Permit: <br /> PW1505-005 <br /> DFR 052 <br /> ...,.,T x <br /> ? Nick Abdelnour(Polygon) I Randy Allen(City of Everett) ; Weather: Mostly Sunny, 60's <br /> Ron Bowen(Polygon) Eddy Stevens(Polygon) Arrival/Departure: 1030/1200 <br /> Distribution: ;�-- --- -- _ <br /> Doug Ross(Polygon) Kirk Keck(City of Everett) <br /> Joe Wester green <br /> i Paul McKee(City of Everett) Dave Foster(City of Everett) Prepared By 9 <br /> m SiteyPlan(s) _ ® Density Test Summary Signature: / <br /> Attachments: _................................. _____-___-_..-...._-.___..__.... ,...._ ....... <br /> (� Installation Records ❑OtherRevie wed By: Xc <br /> PURPOSE of VISIT: GeoDesign representative,Joe Westergreen, was on-site at the request of Eddy Stevens with <br /> Polygon to observe foundation subgrade for Lots 112 and 113. <br /> Uk4MARY of SERVATIONS: <br /> Lot 112: <br /> GeoDesign not that the foundation subcontractor had excavated the footing and crawl space areas for Lot 112 prior to <br /> our arrival o ite. GeoDesign noted that the exposed footing subgrade consisted of a brown-gray silty SAND (f-m)with <br /> that had been exposed using a grade blade. The exposed foundation subgrade was evaluated using a 1/2 inch <br /> diameter soil probe and a Troxier Moisture-Density gauge. Penetration depths encountered ranged from 1 to 2 inches and <br /> in-place density tests indicated that the exposed foundation subgrade material had been compacted to greater than 95%of <br /> its maximum dry density as determined by a Modified Proctor analysis. A summary of our observations and density tests <br /> taken today can be found in the attached Nuclear Density Gauge Data and Figure 1. <br /> It is the opinion of GeoDesign that the exposed foundation subgrade observed today was currently suitable for support of <br /> the intended foundation load. GeoDesign recommends that any loose and saturated material be removed from the base of <br /> the foundation prior to the placement of concrete. <br /> Lot 113: <br /> GeoDesign noted that the foundation subcontractor had excavated the footing and crawl space areas for Lot 113 prior to <br /> our arrival using a Komatsu PC120 excavator with a grade blade. GeoDesign noted that the exposed footing subgrade <br /> consisted of a brown-gray silty SAND (f-m)with gravel (f-c). The exposed foundation subgrade was evaluated using a 1/2 <br /> inch diameter soil probe and a Troxler Moisture-Density gauge. Penetration depths encountered ranged from 1 to 2 inches <br /> and in-place density tests indicated that the exposed foundation subgrade material had been compacted to greater than <br /> 95%of its maximum dry density as determined by a Modified Proctor analysis. A summary of our observations and density <br /> tests taken today can be found in the attached Nuclear Density Gauge Data and Figure 1. <br /> It is the opinion of GeoDesign that the exposed foundation subgrade observed today was currently suitable for support of <br /> the intended foundation load. GeoDesign recommends that any loose and saturated material be removed from the base of <br /> the foundation prior to the placement of concrete. <br /> This report presents opinions formed as a result of our observation of activities relating to geotechnical engineering or environmental services. We rely on the contractor to comply with the plans and <br /> specifications throughout the duration of the project irrespective of the presence of our representative.Ourwork does not include supervision or direction of the contractor,the contractor's employees <br /> or agents, our firm is not responsible for site safety,This field report is a DRAFT representation of our field observations,testing,and preliminary recommendations,The report can only be considered <br /> final upon review of the GeoDesign project manager,as indicated by initials in the"Reviewed By"section. <br /> 10700 Meridian Avenue North,Suite 210 1 Seattle,WA 98133 1 206.838.9900 <br /> 2502 Jefferson Avenue I Tacoma WA_98402 1 253.203.0095 <br />