Laserfiche WebLink
DESIGW! FIELD REPORT <br /> Project Name Everett River Front Simpson Report 021 <br /> t _._. ... --_... ...._.........._ ...__. - --._. ....._ ..... ........ <br /> t GeoDesign# Polygon-127-03 Date: 01/09/2017 <br /> Reports with Unresolved Nonconformance Issues: Permit: <br /> I PW1505-005 <br /> Nick Abdelnour(Polygon) Randy Allen(City of Everett) ; Weather Cloudy, 30's <br /> ---... ..... .--- - — -- _-----------------. - ----- - --.. <br /> Ron Bowen(Polygon) Eddy Stevens(Polygon) Arrival/Departure:1100/1130;1245/1330\ <br /> Distribution: <br /> Doug Ross(Polygon) Kirk Keck(City of Everett) <br /> ...... ........_...._...._ ............................... ..._......._.. .................... .......... ......_.................._.. <br /> Paul McKee(City of Everett) Dave Foster(City of Everett) Pre orad B P <br /> .._._.... <br /> Prepared y Joe Da cevich <br /> m Site Plan(s) m Density Test Summary Signature: ^` <br /> Attachments- _--� -- - - Reviewed By: <br /> PURPOSE <br /> Installation Records ❑ Other <br /> PURPOSE of VISIT: GeoDesign representative, Joe Dapcevich, was on-site part time at the request of John Feltner with <br /> Polygon to observe the foundation subgrade for Lots 159 and 160. <br /> SUMMARY of OBSERVATIONS: <br /> Lot 159: <br /> GeoDesign was informed that the foundation subgrade for 159 had been excavated to the planned elevation before arrival <br /> onsite. Soils consisted of native silty sand with gravel. Relative compaction of the exposed footing subgrade was tested <br /> using a Troxler Moisture-Density gauge. In-place density tests indicated that the exposed footing subgrade had been <br /> compacted to greater than 95%of its maximum dry density as determined by a Modified Proctor analysis. Hand probing <br /> the surface with a 1/2" diameter steel foundation rod indicated approximately 1-2"of surficially loose and saturated material <br /> and areas of shallow standing water(approximately 1-2" deep). We continue to recommend removing the water and <br /> surficially saturated material prior to pouring of footings. A summary of density tests taken and observations can be found <br /> in the attached Figure 1 and Nuclear Density Gauge Data. <br /> Lot 160: <br /> GeoDesign observed the foundation subgrade being prepared to the planned elevation. Soils consisted of native silty sand <br /> with gravel. Relative compaction of the exposed footing subgrade was tested using a Troxler Moisture-Density gauge. <br /> In-place density tests indicated that the exposed footing subgrade had been compacted to greater than 95% of its maximum <br /> dry density as determined by a Modified Proctor analysis. Hand probing the surface with a 1/2"diameter steel foundation <br /> rod indicated dense soil conditions. A summary of density tests taken and observations can be found in the attached Figure <br /> 1 and Nuclear Density Gauge Data. <br /> It is the opinion of GeoDesign that the exposed footing subgrade is currently suitable for support of the intended structure. <br /> GeoDesign recommends that any surficially loose or saturated material that may build up under the footing area be <br /> removed prior to the placement of concrete. A summary of our observations can be found in the attached Figure 1. John <br /> Feltner with Polygon was notified of our observations prior to our departure from the site. <br /> A summary of our observations can be found in the attached Figure 1. <br /> This report presents opinions formed as a result of our observation of activities relating to geotechnical engineering or environmental services.We rely on the contractor to comply with the plans and <br /> specifications throughout the duration of the project irrespective of the presence of our representative. Our work does not include supervision or direction of the contractor,the contractor's employees <br /> or agents. Our firm is not responsible for site safety.This field report is a DRAFT representation of our field observations,testing,and preliminary recommendations. The report can only be considered <br /> final upon review of the GeoDesign project manager,as indicated by initials in the"Reviewed By'section. <br /> 10700 Meridian Avenue North,Suite 402 1 Seattle,WA 98133 1 206.838.9900 <br /> 2502 Jefferson Avenue I Tacoma,WA 98`402 1 253.203.0095 <br />