4323 30TH DR SE 2017-09-11
>
Address Records
>
30TH DR SE
>
4323
>
4323 30TH DR SE 2017-09-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/11/2017 1:54:01 PM
Creation date
9/11/2017 1:53:52 PM
Metadata
Fields
Template:
Address Document
Street Name
30TH DR SE
Street Number
4323
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DESIGNuz FIELD REPORT <br /> project Name: Everett River Front- Simpson Report: 021 <br /> GeoDesign # : Polygon-127-03 Date: 01/09/2017 <br /> Reports with Unresolved Nonconformance Issues: Permit: <br /> PWS 15(05-005 <br /> Nick Abdelnour(Polygon) Randy Allen(City of Everett) Weather: Cloudy, 30's <br /> Distribution: <br /> Ron Bowen(Polygon) Eddy Stevens(Polygon) Arrival/Departure:1100/1130;1245/1330 <br /> --- <br /> Doug Ross(Polygon) Kirk Keck(City of Everett) <br /> Paul McKee(City of Everett) Dave Foster(City of Everett) Prepared By: Joe Dapcevich <br /> m Site Plan(s) m Density Test Summary Signature: <br /> Attachments: Installation Records 0 Other Reviewed By: <br /> PURPOSE of VISIT: GeoDesign representative, Joe Dapcevich, was on-site part time at the request of John Feltner with <br /> Polygon to observe the foundation subgrade for Lots 159 and 160. <br /> SUMMARY of OBSERVATIONS: <br /> Lot 159: <br /> GeoDesign was informed that the foundation subgrade for 159 had been excavated to the planned elevation before arrival <br /> onsite. Soils consisted of native silty sand with gravel. Relative compaction of the exposed footing subgrade was tested <br /> using a Troxler Moisture-Density gauge. In-place density tests indicated that the exposed footing subgrade had been <br /> compacted to greater than 95% of its maximum dry density as determined by a Modified Proctor analysis. Hand probing <br /> the surface with a 1/2"diameter steel foundation rod indicated approximately 1-2" of surficially loose and saturated material <br /> and areas of shallow standing water(approximately 1-2" deep). A summary of density tests taken and observations can be <br /> found in the attached Figure 1 and Nuclear Density Gauge Data. <br /> We continue to recommend removing the water and surficially saturated material prior to pouring of footings. <br /> Lot 160: <br /> GeoDesign observed the foundation subgrade for Lot 160 being prepared to the planned elevation. Soils consisted of native <br /> silty sand with gravel. Relative compaction of the exposed footing subgrade was tested using a Troxler Moisture-Density <br /> gauge. In-place density tests indicated that the exposed footing subgrade had been compacted to greater than 95%of its <br /> maximum dry density as determined by a Modified Proctor analysis. Hand probing the surface with a 1/2" diameter steel <br /> foundation rod indicated dense soil conditions. A summary of density tests taken and observations can be found in the <br /> attached Figure 1 and Nuclear Density Gauge Data. <br /> It is the opinion of GeoDesign that the exposed footing subgrade is currently suitable for support of the intended <br /> structure. GeoDesign recommends that any surficially loose or saturated material that may build up under the <br /> footing area be removed prior to the placement of concrete. <br /> John Feltner with Polygon was notified of our observations prior to our departure from the site. <br /> This report presents opinions formed as a result of our observation of activities relating to geotechnical engineering or environmental services.We rely on the contractor to comply with the plans and <br /> specifications throughout the duration of the project Irrespective of the presence of our representative.Ourwork does not include supervision or direction of the contractor,the contractor's employees <br /> or agents. Our firm is not responsible for site safety.This field report is a DRAFT representation of our field observations,testing,and preliminary recommendations.The report can only be considered <br /> final upon review of the GeoDesign project manager,as indicated by initials in the"Reviewed By"section. <br /> 10700 Meridian Avenue North,Suite 402 1 Seattle,WA 98133 1 206.838.9900 <br /> 2502 Jefferson Avenue 1 Tacoma,WA 98402 1 253.203.0095 <br />
The URL can be used to link to this page
Your browser does not support the video tag.