Laserfiche WebLink
• C1110 - P15 • <br /> �3, D ���! FIELD REPORT <br /> ESu 1 of <br /> Report: 011 <br /> Project Name Everett River Front-Simpson P.. ..._'. _.._ <br /> ............... <br /> ........ ........ <br /> GeoDesign#: Polygon 127 03 <br /> Date: 12/07/201 <br /> Reports with Unresolved Nonconformance Issues: Permit: <br /> PW1505-005 <br /> i <br /> i <br /> Nick Abdelnour(Polygon) Randy Allen(City of Everett) Weather: Clear, 30rS <br /> ......... — —)— .� <br /> __-- <br /> 300 <br /> Ron Bowen(Polygon) Eddy Stevens(Polygon) ; Arrival/Departure- 1145/1 <br /> DISLrIt)UilOn: Doug Ross(Polygon) Kirk Keck(City of Everett) <br /> ... ..... <br /> ...,, <br /> Paul McKee(City of Everett) Dave Foster(City of Everett) i Prepared B. Ben Weinberg E I <br /> c_ ... .._... _..._.. ............................ ..__... ........ .__. .... .,, ......... <br /> m SitePlan(s) m ry <br /> Dens/ Test Summary Signature: <br /> Attachments: —_._....^__ <br /> ❑ Installation Records ❑ Other Reviewed By: <br /> PURPOSE of VISIT: GeoDesign representative, Benjamin Weinberg, was on-site part time at the request of John Feltner <br /> with Polygon to observe the foundation subgrade for Lot 138 and 137. <br /> SUMMARY of OBSERVATIONS: <br /> Lot138: <br /> Upon arrival, GeoDesign noted that the foundation excavation subcontractor had completed digging the footing and crawl <br /> space area for Lot 138. GeoDesign noted that the exposed footing subgrade generally consisted of a gray-brown silty <br /> SAND (f-m)with gravel which could be penetrated less than 2 inches using a 1/2 inch diameter soil probe. <br /> Relative compaction of the exposed subgrade soils were tested using a Troxier Moisture-Density gauge. In-place density <br /> tests indicated that the material had been compacted to greater than 95% of its maximum dry density as determined by a <br /> Modified Proctor analysis. <br /> It is the opinion of GeoDesign that the exposed footing subgrade observed today is currently suitable for support of the <br /> intended structure. GeoDesign recommends that any surficially loose and saturated material be removed from the base of <br /> the footing areas prior to the placement of concrete. <br /> Lot 137: <br /> Upon arrival, GeoDesign noted that the foundation excavation subcontractor had completed digging the footing and crawl <br /> space area for Lot 137. GeoDesign noted that the exposed footing subgrade generally consisted of a gray-brown silty <br /> SAND (f-m)with gravel which could be penetrated less than 2 inches using a 1/2 inch diameter soil probe. <br /> Relative compaction of the exposed subgrade soils were tested using a Troxier Moisture-Density gauge. In-place density <br /> tests indicated that the material had been compacted to greater than 95%of its maximum dry density as determined by a <br /> Modified Proctor analysis. <br /> It is the opinion of GeoDesign that the exposed footing subgrade observed today is currently suitable for support of the <br /> intended structure. GeoDesign recommends that any surficially loose and saturated material be removed from the base of <br /> the footing areas prior to the placement of concrete. <br /> A summary of our observations can be found in the attached Figure 1 and Nuclear Density Gauge Data. John Feltner with <br /> Polygon was notified of our observations prior to our departure from the site. <br /> This report presents opinions formed as a result of our observation of activities relating to geotechnical engineering or environmental services. We rely on the contractor to comply with the plans and <br /> specifications throughout the duration of the project irrespective of the presence of our representative. Our work does not include supervision or direction of the contractor,the contractor's employees <br /> or agents. Our firm is not responsible for site safety.This field report is a DRAFT representation of our field observations,testing,and preliminary recommendations. The report can only be considered <br /> final upon review of the GeoDesign project manager,as indicated by initials in the"Reviewed By'section. <br /> 10700 Meridian Avenue North,Suite 402 1 Seattle,WA 98133 1 206.838.9900 <br /> 2502 Jefferson Avenue I Tacoma,WA 98402 1 253.203.0095 <br />