Laserfiche WebLink
Permit#: FA1401-005 <br /> Site Address: 5126 S 2ND AVE FIRE ALARM CONTROL PANEL <br /> Owner: EVERETT GOSPEL MISSION <br /> Tenant: EVERETT GOSPEL WOMENS SHELTER <br /> App. Date: 1/23/2014 <br /> Proposed Use: COMMERCIAL SK-4 & SK-4E Fire Alarm <br /> Description: REPLACE FIRE ALARM CONTROL PANEL Control Panel <br /> 424.'04- <br /> Reviewed By: Date:l '07)°1 <br /> 4-zone fire protection at a price <br /> Office Set Job Site Set Fire/Planning Set that won't burn your budget. <br /> The SK-4 and SK-4E (SK-4/E) are four zone conventional fire alarm control panels (FACPs) that bring the latest <br /> in microprocessor technology to conventional fire controls. The SK-4 is a 120 VAC FACP and the SK-4E is a <br /> 240 VAC FACP. These FACPs provide reliable fire signaling protection for small-to medium-sized commercial, <br /> industrial, and institutional buildings. <br /> For more information about the SK-4/E system, or to locate your nearest source, please call <br /> 1-800-328-0103. <br /> Description • Selectable for System Sensor, <br /> Wheelock, and Gentexprotocols <. <br /> The four zone SK-4/E is a 24 VDC "`�" , <br /> FACP that provides four Class B • Selective silence feature allows a nIr � <br /> initiating device circuits and two Class manual silence of horns while strobes �r5r <br /> B notification appliance circuit (NAC). continue to flash on the same NAC <br /> 'fir.. <br /> • Program for combination tamper <br /> The SK-4/E NAC protocol includes the supervisory monitor and waterflow <br /> ability to silence audible devices while alarm on one zone <br /> strobes continue to flash, using only a • Silent or audible walk test operation 1-17.4-7;;:..-7.- <br /> single pair of wires. The SK-4/E is also mode <br /> compatible with conventional input • Alarm verification selectable per zone - <br /> devices such as two-and four-wire <br /> smoke detectors, pull stations, • Program each zone for supervisory or <br /> fire with separate red and yellow <br /> waterflow devices, tamper switches and LEDs ®SILENT <br /> w <br /> NICMT <br /> other normally-open contact devices. .4,,--, <br /> • Disable switches provided per zone ----- <br /> Activation of a compatible smoke • Program NACS for ��' 5 <br /> detector or any normally-open fire -Silence inhibit <br /> alarm initiating device activates audible -Auto silence SK-4 <br /> and visual signaling devices, illuminates _Strobe synchronization <br /> an indicating LED, sounds the piezo NACs <br /> -Temporal or steady signal <br /> sounder at the FACP, activates the Signaling Current: @ 24 VDC <br /> FACP alarm relay, and operates an -Silenceable or nonsilenceable with standard transformer or 5A <br /> optional module used to notify a remote -Disable total (2.5A per NAC)with additional <br /> station or initiate an auxiliary control • Form C alarm, trouble, and optional transformer, power limited <br /> function. supervisory relays EOL Resistor:4.7K 1/2 watt <br /> • 3A total usable current Form C Relays <br /> The SK-4/E is compatible with System Types:Trouble, alarm, and <br /> Sensor® 13 detectors providing • 6A total usable current with optional supervisory <br /> advanced features such as drift second transformer(PN SK-TRM24 Contact Ratings: 2A @ 30 VAC, <br /> or SK-TRM24E) resistive <br /> compensation, maintenance alert, and • Optional dress panel (PN SK-DP2/4) Auxiliary Output <br /> freeze warning.Automatic Resettable and non-resettable <br /> synchronization of audio/visual devices Electrical Specifications Operating Voltage: 24 VDC nominal <br /> is provided, using three selections for SK-4 Primary AC: 120 VAC @ 50/60 Current: 500 mA max, power-limited; <br /> manufacturer protocol. Hz, 2.3A total current for nonresettable power, <br /> Features SK-4E Primary AC: 240 VAC @ 50 Hz, resettable power and two NACs must <br /> 1.15A not exceed 6.0A(requires additional <br /> • Four Style B (Class B) initiating Wiring: 14 AWG (2.0 mm2)with 600 V transformer) <br /> device circuits (IDCs) insulation min <br /> • Two Style Y(Class B) notification Initiating Device Circuits (IDCs) <br /> appliance circuit(NAC) Operating Voltage: 22 VDC nominal; ry_ <br /> • Optional module converts all IDCs power-limited <br /> and NACs to Class A(PN SK-CAC4) Standby Current:4 mA - ' <br /> • Support for synchronization of Alarm Current: 15 mA min F�� <br /> standard ANSI audible signals and Short-circuit Current: 40 mA max L�l� <br /> ADA compliant strobes per NFPA 72 Loop Resistance: 100 max <br /> EOL Resistor: 4.7K Q, 1/2 watt CITY Q EVERETT <br /> Perms, Services <br />