My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9111 9TH AVE SE 2017-10-05
>
Address Records
>
9TH AVE SE
>
9111
>
9111 9TH AVE SE 2017-10-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/5/2017 3:47:06 PM
Creation date
9/25/2017 11:08:15 AM
Metadata
Fields
Template:
Address Document
Street Name
9TH AVE SE
Street Number
9111
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2015 INTERNATIONAL RESIDENTIAL CODE <br /> R325.8.4.2 Horizontal grab bars.Horizontal grab <br /> SECTION R326 <br /> bars shall be provided at the control end,head end,and FAMILY HOME CHILD CARE <br /> the back wall within the bathtub area.Grab bars shall R326 Family home child care.For family home child care <br /> be mounted between 33 inches and 36 inches above with more than six children,each floor level used for family <br /> floor grade.Control end and head end grab bars shall child care purposes shall be served by two remote means of <br /> be 24 inches minimum in length.Back wall grab bar egress.Exterior exit doors shall be operable from the inside <br /> shall be 36 inches minimum in length. without the use of keys or any special knowledge or effort. <br /> R325.8.5 Grab bars at shower stalls.Where shower Basements located more than 4 feet below grade level <br /> stalls are provided to meet the requirements for bathing shall not be used for family home child care homes unless <br /> facilities,grab bars shall meet the requirements of one of following conditions exist: <br /> R325.8. 1. Stairways from the basement open directly to the <br /> Exception: Shower stalls with permanent built-in seats exterior of the building without entering the first <br /> are not required to have vertical or horizontal grab bars floor;or <br /> at the seat end wall.A vertical floor to ceiling grab bar 2. One of the two required means of egress discharges <br /> shall be installed within 4 inches of the exterior of the directly to the exterior from the basement level,and <br /> shower aligned with the nose of the built-in seat. a self-closing door is installed at the top or bottom of <br /> R325.8.5.1 Vertical grab bars.Vertical grab bars the interior stair leading to the floor above;or <br /> shall be 18 inches minimum in length and installed at 3. One of the two required means of egress is an <br /> the control end wall and head end wall.Vertical bars operable window or door,approved for emergency <br /> shall be mounted within 4 inches of the exterior of the escape or rescue,that opens directly to a public <br /> shower stall or within 4 inches inside the shower stall. street,public alley,yard or exit court;or <br /> The bottom end of vertical bars mount between 36 4. A residential sprinkler system is provided throughout <br /> inches and 42 inches above floor grade. the entire building in accordance with NFPA 13D. <br /> R325.8.5.2 Horizontal grab bars.Horizontal grab Floors located more than 4 feet above grade level shall not <br /> bars shall be installed on all sides of the shower stall be occupied by children in family home child care. <br /> mounted between 33 inches and 36 inches above the Exceptions: <br /> floor grade.Horizontal grab bars shall be a maximum 1. Use of toilet facilities while under supervision of <br /> of 6 inches from adjacent walls.Horizontal grab bars an adult staff person. <br /> shall not interfere with shower control valves. <br /> 2. Family home child care may be allowed on the <br /> R325.9 Ramps.All interior and exterior ramps,when second story if one of the following conditions <br /> provided,shall be constructed in accordance with Section exists: <br /> R311.8 with a maximum slope of 1 vertical to 12 2.1. Stairways from the second story open <br /> horizontal.The exception to R311.8.1 is not allowed for directly to the exterior of the building <br /> adult family homes.Handrails shall be installed in without entering the first floor;or <br /> accordance with R325.9.1. <br /> R325.9.1 Handrails for ramps.Handrails shall be 2.2. One the two required means of egress <br /> installed on both sides of ramps between the slope of 1 discharges directly to the exterior from the <br /> second story level,and a self closing door is <br /> vertical to 12 horizontal and 1 vertical and 20 horizontal <br /> in accordance with R311.8.3.1 through R311.8.3.3. installed at the top or bottom of the interior <br /> stair leading to the floor below;or <br /> R325.10 Stair treads and risers.Stair treads and risers 2.3. A residential sprinkler system is provided <br /> shall be constructed in accordance with R311.7.5.Handrails throughout the entire building in accordance <br /> shall be installed in accordance with R325.10.1. with NFPA 131). <br /> R325.10.1 Handrails for treads and risers.Handrails Every sleeping or napping room in a family home child care <br /> shall be installed on both sides of treads and risers shall have at least one operable window for emergency <br /> numbering from one riser to multiple risers.Handrails rescue. <br /> shall be installed in accordance with R311.7.8.1 through Exception: Sleeping or napping rooms having doors <br /> R311.7.8.4. leading to two separate means of egress,or a door <br /> R325.11 Shower stalls.Where provided to meet the leading directly to the exterior of the building. <br /> requirements for bathing facilities,the minimum size of Rooms or spaces containing a commercial-type cooking <br /> shower stalls for an adult family home shall be 30 inches kitchen,boiler,maintenance shop,janitor closet,laundry, <br /> deep by 48 inches long. woodworking shop,flammable or combustible storage,or <br /> (Insert as Page 77b) <br /> f �,- <br /> r <br /> Effective July 1, 2016 ��j <br />
The URL can be used to link to this page
Your browser does not support the video tag.