My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
13110 19TH AVE SE 2017-09-25
>
Address Records
>
19TH AVE SE
>
13110
>
13110 19TH AVE SE 2017-09-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/25/2017 2:45:22 PM
Creation date
9/25/2017 2:45:01 PM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
13110
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
84
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2012 Washington Stawrgy Code Compliance Forms for Commercial,Group R1W>3 story R2 and R3 <br /> PermitMechanical Plans ■ • <br /> 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised Aug 2015 <br /> Project Address 2205 BROADWAY Date 5/13/2016 <br /> The following information is necessary to check a permit application for compliance with the mechanicial systems and equipment requirements of the <br /> Washington State Energy Code,Commercial Provisions. <br /> Applicable Code Section Code Provision Information Required-Must be in permit documents Location t Building Department <br /> (yes,no,n3) Documents Notes <br /> GENERAL PROVISIONS,CONTINUED <br /> HVAC System Controls&Criteria,Continued <br /> Enclosed loading Indicate enclosed loadingdock and enclosed parking <br /> na C403.2.5.3 dock/parking garage P g garage ventilation system activation and <br /> control method <br /> ventilation <br /> na C403.2.5.4.1 Kitchen exhaust hoods Indicate kitchen hoods requiring make-up air,indicate make-up air source and conditioning <br /> method <br /> na C403.2.5.4.2 Laboratory exhaust systems Indicate lab exhaust systems requiring heat recovery,method&efficiency,or alternative <br /> method taken(VAV,semi-conditioned makeup,or CERM calculation) <br /> na C403.2.6.1 Energy recovery(ER)- Indicate ventilations stems requiring ER,method&efficiency: <br /> ventilation systems y q 9 cy;note exceptions <br /> na C403.2.6.2 Energy recovery(ER)- Indicate on-site steam heating systems requiring energy recovery <br /> condensate systems <br /> na C403.2.6.3 Energy recovery(ER)- Indicate remote refrig.condensers requiring ER and use of captured energy <br /> cooler/freezer condensers <br /> na C403.4.6 Energy recovery(ER)- Indicate condenser systems requiring ER to pre-heat service water,indicate ER effectiveness, <br /> condenser systems note exceptions taken <br /> na C403.2.12 Variable flow control- Indicate fan and pump motors>_7.5 hp and the method of variable flow control(VSD or <br /> fans/pumps equivalent controls) <br /> na C403.2.12.1 Variable flow control-heat Indicate heat rejection equipment and cooling tower fans requiring variable flow control and <br /> rejection equipment method <br /> Indicate single zone fan systems requiring airflow reduction capability in response to reduced <br /> na C403.2.12.2 Large volume fan systems cooling or heating demand in a zone,or adjacent zones without separating walls,with>10,000 <br /> CFM supply air;note exceptions taken <br /> na C403.2.12.2 Single zone AC systems Indicate method of cooling demand-based fan control for air conditioning systems>110,000 <br /> Btu/h serving single zones <br /> na C403.2.4.10DDC system capabilities Identify all DDC system input/output control points and indicate capability for trending and <br /> demand res onse setpoint adjustment <br /> Ducting Systems <br /> yes C403.2.7.1& Duct construction Indicate all ductwork constructed and sealed per IMC,C402.4 leakage requirements and IBC SPEC <br /> C403.2.7.3 vapor retarder requirements 200700 <br /> M-111& <br /> yes 403.2.7.3.1- Duct pressure classifications Identify location of low,medium and high pressure ductwork on plans SPEC <br /> 233000 <br /> na C403.2.7.3.3 High pressure duct leakage Indicate high pressure duct leakage testing requirements on plans;provide test results to <br /> test jurisdiction when completed <br /> yes C403.2.7.1/IDuct insulation Indicate R-value of insulation on ductwork 200700 <br /> Piping Systems <br /> yes C403.2.8 Piping insulation Indicate R-value of insulation on piping SPEC <br /> 200700 <br /> yes C403.2.8.1 Piping insulation exposed to Indicate method of protection from damage/degredation SPEC <br /> weather 200700 <br /> SIMPLE SYSTEMS <br /> Qualifying Systems <br /> Qualifying single zone Verify unitary or packaged equipment does not exceed capacity limits,does not have active M-111& <br /> yes C403.3 MECH- <br /> systems humidifcation or simultaneous heating/cooling EQUIP <br /> na C403.3 Qualifying 2-pipe heating Verify 2-pipe heating-only system does not exceed capacity limits <br /> systems <br /> na C403.3.2 Hydronic system controls Refer to Complex Systems Section C403.4.3 <br /> Simple System Economizers <br /> na C403.3.1 Air economizer required Indicate cooling systems requiring economizer controls;note in equipment schedule <br /> i <br />
The URL can be used to link to this page
Your browser does not support the video tag.