Laserfiche WebLink
2012 Washington Staorgy Code Compliance Forms for Commercial,Group R1.>3 story R2 and R3 <br /> PermitMechanical Plans Page 3 <br /> , <br /> 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised Aug 2015 <br /> Project Address 2205 BROADWAY Date 5/13/2016 <br /> The following information is necessary to check a permit application for compliance with the mechanicial systems and equipment requirements of the <br /> Washington State Energy Code,Commercial Provisions, <br /> Applicable Cade Section Code Provision Information Required-Must be in permit documents Location in Building Department <br /> (yes,no,na) Documents Notes <br /> COMPLEX SYSTEMS <br /> Complex System Economizers <br /> na C403.4.1 Air economizer required Indicate cooling systems requiring economizer controls;note in equipment schedule <br /> na C403.4.1 Air economizer exceptions Indicate eligible exception(s)taken and provisions to comply with exception(s) <br /> na C403.4.1.1 Water economizer capacity For eligible systems where water economizer may be provided in lieu of air economizer, <br /> indicate system is capable of 100%cooling capacity at 50°F db/45°F wb OSA <br /> na C403.4.1.2 Water economizer Indicate precooling coils and heat exchangers in water economizer system do not exceed <br /> maximum pressure drop pressure drop limit <br /> na C403.4.1.3 Integrated economizer Indicate capability for partial economizer operation for air or water economizer systems <br /> operation <br /> na C403.4.1.4 Economizer heating system Verify control method of HVAC systems with economizers does not increase building heating <br /> impact energy usage during normal operation <br /> Specific System Requirements <br /> na C403.4.2& VAV fan control Indicate fans requiring variable flow control and method <br /> C403.2.12 <br /> na C403.4.2.1 VAV fan static pressure Indicate sensor locations on plans;include at least one sensor per major duct branch <br /> sensors <br /> na C403.4.2.2 VAV fan static pressure Indicate fan system static pressure setpoint based on zone requiring most pressure <br /> setpoint <br /> na C403.4.5 VAV systems serving Indicate supply air systems serving multiple zones,method of primary air control,and zones <br /> multiple zones served,Indicate VAV or note exceptions taken <br /> na C403.4.5 VAV systems serving For each air system terminal,indicate the maximum air flow rate of primary supply air during <br /> multiple zones zone peak cooling and the maximum airflow rates during zone peak heating. <br /> na C403.4.5.4 VAV system supply air reset Indicate controls that automatically reset supply air temp in response to loads <br /> na C403.4 Large capacity cooling Indicate method of multi-stage or variable control for building cooling system capacity>300 <br /> systems tons <br /> na C403.4.7 Hot gas bypass limitation Indicate cooling equipment unloading or capacity modulation method <br /> na C403.4.3 Large capacity boiler Indicate multi-stage or modulating burner for single boilers>500,000 Btu/h <br /> systems <br /> na C403.4.3 Boiler sequencing Indicate automatic controls that sequence operation of multiple boilers <br /> na C403.4.3.5 Chiller/boiler plant pump Indicate capability to automatically reduce overall plant flow and shut-off flow through chillers& <br /> isolation boilers when not in use <br /> na C403.4.3.6& Variable flow control- Indicate pumps requiring variable flow control&method <br /> C403.2.12 pumps <br /> na C403.2.12.1 Variable flow control- Indicate cooling tower fans requiring variable flow control and method <br /> &C403.4.4 cooling towers <br /> na C403.4.3.4 Hydronic system part load Indicate heating&chilled water systems have the capability to automatically reset supply water <br /> controls temp AND reduce flow by>_50%for systems>300,000 Btu/h <br /> na C403.4.3.2 Two-pipe changeover Indicate deadband,heating/cooling mode scheduling and changeover temperature range <br /> systems <br /> na C403.4.3.3.1 Water loop heat pump- Indicate capability of central equipment to provide min.20°F water supply temp deadband <br /> deadband between heat rejection and heat addition modes <br /> na C403.4.3.3.2.1Water loop heat pump- Indicate method used to limit system heat loss when heat rejections is not needed <br /> heat rejection,Zone 4 <br /> na C403.4.3.3.2.2 Water loop heat pump- Provide heat exchanger that separates cooling tower and heat pump loop <br /> heat rejection,Zone 5 <br /> na C403.4.3.3.3 Water loop heat pump- Indicate 2-way isolation valve on each heat pump and variable flow control for systems with <br /> isolation total pump power,10 hp <br /> na C403.5 Walk-in cooler/freezer- Indicate w/sf&control method for walk-in cooler/freezer door anti-sweat heaters <br /> anti-sweat heaters <br />