My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
13110 19TH AVE SE 2017-09-25
>
Address Records
>
19TH AVE SE
>
13110
>
13110 19TH AVE SE 2017-09-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/25/2017 2:45:22 PM
Creation date
9/25/2017 2:45:01 PM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
13110
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
84
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised Jan 2014 <br /> Project Address 2205 BROADWAY Date 5/13/2016 <br /> Lighting Alterations, Renovations & Building Additions For Building Department Use <br /> 0 Less than 60% 0 60%or more 0 Stand alone 0 Addition <br /> Notes: <br /> a.Lighting fixtures in a building addition may comply as a stand alone project,or they may be <br /> combined with the overall existing bldg lighting to demonstrate compliance. Refer to C101.4.3. <br /> b.For retrofits and building additions,provide Space Types and gross interior areas in the <br /> Maximum Allowed Lighting table.If a builidng addition will comply as combined with the overall <br /> existing builidng,include all applicable existing Space Types and gross interior areas. <br /> c.Document new fixtures and all existing to remain fixtures in the Proposed Lighting table. <br /> d. If less than 60%of existing fixtures will be replaced,provide total existing lighting wattage <br /> (prior to retrofit)in the space provided in the Maximum Allowed Lighting table. <br /> Maximum Allowed Lighting Wattage <br /> Location(plan Allowed Gross interior VVattS Allowed <br /> room#) Space Type` Watts per ft2 Area in ft2 (watts/ft2 x area) <br /> E-111,Consult Room Health care clinic/hospital:Examttreatment 1.66 105 174 <br /> 1 <br /> E-1 1 1,Consult Room Health care clinic/hospital:Exam/treatment 1.66 101 168 <br /> 2 <br /> E-111,Tech Closet Electrical/mechanical 0.95 30 29 <br /> E-111,NA Storage 0.63 270 170 <br /> E-111,NA Retail:Sales area 1.68 30 50 <br /> Atrium** Enter Height: <br /> Existing Lighting Enter Exist.Watts: <br /> Retail Display Allowance from LTG-INT-DISPLAY <br /> Select Table C405.5.2(2)category from drop down menu. Area Allowed Watts <br /> '* For atriums,indicate height.Allowed wattage for first 40 feet is 0.03 W/it.ht., Total 536 591 <br /> above 40 feet is 0.02 W/ft.ht. <br /> Proposed Lighting Wattage <br /> Location(plan#, Number of Watts/ Watts <br /> room#) Fixture Description— Fixtures Fixture Proposed <br /> E-111,Consult Room 2'x4'RECESSED LED TROFFER 2 44 88 <br /> 1 <br /> E-111,Consult Room 2'x4'RECESSED LED TROFFER 2 44 88 <br /> 2 <br /> E-111,Tech Closet T WALL MOUNTED LED 1 33 33 <br /> E-111,N/A 4'LINEAR SUSPENDED LED STRIP LIGHT 4 44 176 <br /> E-111,Restrooms 1'x4'RECESSED LED TROFFER 2 44 88 <br /> E-1 1 1,Consult Room 2.UNDERCABINET LED 1 9 9 <br /> 1 <br /> E-111,Consult Room T UNDERCABINET LED 1 9 9 <br /> 2 <br /> E-111,Sales Area 1'x4'RECESSED LED TROFFER 1 44 44 <br /> Retail Display Lighting from LTG-INT-DISPLAY <br /> Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Wattl 534 <br /> *'*Include existing to remain lighting fixtures and exempt lighting equipment per notes below. <br /> Notes: <br /> 1. Include ALL proposed lighting fixtures. <br /> 2.For proposed Fixture Description,indicate fixture type,lamp type(e.g. T-8),number of lamps in the fixture,and ballast type(if included).For <br /> track lighting,list the length of the track(in feet)in addition to the fixture,lamp,and ballast information. <br /> 3.For proposed Watts/Fixture,use manufacturer's listed maximum input wattage of the fixture(not simply the lamp wattage)and other criteria <br /> as specified in Section C405.5.1.For line voltage track lighting,list the greater of actual luminaire wattage or length of track multiplied by 50, <br /> or as applicable,the wattage of current limiting devices of the transformer.For low voltage track lighting list the transformer rated wattage. <br /> 4.For lighting equipment eligible for exemption per C405.5.1,note exception number and leave Watts/Fixture blank. <br /> 5.Document existing to remain fixtures in Proposed Lighting table in the same manner as new fixtures.Identify as existing in fixture description. <br /> 6.If#NA appears in Retail Display cells,information on LTG-INT-DISPLAY is incomplete. <br /> Interior Lighting Power Allowance COMPLIES <br />
The URL can be used to link to this page
Your browser does not support the video tag.