My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Ordinance 1776-91
>
Ordinances
>
Ordinance 1776-91
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/28/2017 9:37:10 AM
Creation date
9/28/2017 9:37:07 AM
Metadata
Fields
Template:
Ordinances
Ordinance Number
1776-91
Date
4/3/1991
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> $50,001 to $250,000 557 + .8% of cost <br /> over 50,000.00 <br /> $250,001 to $1,000,000 2157 + .6% of cost <br /> $1,000,001 and above 6657 + .4% of cost <br /> over 1,000,000.00 <br /> Permits for apartments or condominium complexes require one <br /> permit per building. If individual buildings do not have a <br /> separate contract price, take the total contract price and divide <br /> by the number of buildings in each complex. This amount will be <br /> used as the contract price for each building and then the fees <br /> would be figured accordingly to the above Commercial schedule. <br /> Inspections Requested for Existing <br /> Electrical Facilities $ 30.00 <br /> Work Started Without Permit, <br /> Except Emergency Work $30.00 plus double fee <br /> Fire Alarm Systems Commercial Rate <br /> Inspections outside of normal working hours shall be time and <br /> one-half of the prevailing wage scale, plus mileage from the <br /> origin of inspector's residence. <br /> B. The National Electrical Code is hereby amended by deleting the <br /> following: <br /> ARTICLE 700-12. SOURCES OF POWER - EMERGENCY SYSTEMS <br /> (c) Emergency systems. <br /> (d) Separate Service. Where acceptable to the authority having <br /> jurisdiction, a second service shall be permitted. This <br /> service shall be in accordance with Article 230, with <br /> separate service drop or lateral, widely separated <br /> electrically and physically from the normal service to <br /> minimize the possibility of simultaneous interruption of <br /> supply. <br /> (e) Connection Ahead of Service Disconnecting Means. Where <br /> acceptable to the authority having jurisdiction, <br /> connections ahead of, but not within, the main service <br /> disconnecting means shall be permitted. The emergency <br /> service shall be sufficiently separated from the normal <br /> main service disconnecting means to prevent simultaneous <br /> 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.