DESIGN CRITERIA: <br />THE STRUCTURAL DESIGN OF THIS PROJECT IS IN ACCORDANCE WITH <br />THE INTERNATIONAL BUILDING CODE 2012 WITH WASHINGTON STATE <br />BUILDING CODE AMENDMENTS (2012) <br />2. DESIGN LOADS: <br />DESIGN DATA FOR MARYSVILLE, WASHINGTON <br />-ROOF SNOW LOAD N/A (NOT A ROOFTOP SOLUTION) <br />-BASIC WIND SPEED 85 MPH <br />-WIND EXPOSURE C <br />-SEISMIC ZONE D <br />CONCRETE NOTES: <br />1. ALL CONCRETE CONSTRUCTION SHALL BE IN ACCORDANCE WITH <br />ACI-318. <br />2. CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED AND PLACED IN <br />ACCORDANCE WITH CHAPTER 19 OF THE 2009 IBC WITH WASHINGTON <br />AMENDMENTS. STRENGTHS AT 28 DAYS AND MIX CRITERIA SHALL BE <br />AS FOLLOWS UNLESS OTHERWISE NOTED. <br />28 DAY STRENGTHS W/C RATIO MINIMUM CEMENT CONTENT <br />(f'c) PER CUBIC YARD <br />2,500 PSI <.45 5 1/2 SACKS <br />CEMENT SHALL BE ASTM C150, PORTLAND CEMENT TYPE II U.N.O. <br />3. THE GENERAL CONTRACTOR SHALL SUPERVISE AND BE RESPONSIBLE <br />FOR THE METHODS AND PROCEDURES OF CONCRETE PLACEMENT. <br />4. ALL CONCRETE WITH SURFACES EXPOSED TO WEATHER SHALL BE <br />AIR -ENTRAINED WITH AN AIR -ENTRAINING AGENT CONFORMING TO ASTM <br />C260, C494, C618, C989 AND C1017. CONCRETE EXPOSED TO <br />FREEZING AND THAWING WHILE MOIST SHALL BE AIR ENTRAINED IN <br />ACCORDANCE WITH ACI 318. SECTION 4.4.1. <br />5. REINFORCING STEEL SHALL CONFORM TO ASTM A615 (INCLUDING <br />SUPPLEMENT S1), GRADE 60. fy=60,000 PSI. EXCEPTIONS: ANY BARS <br />SPECIFICALLY SO NOTED ON THE DRAWINGS SHALL BE GRADE 40, <br />fy=40,000 PSI. GRADE 60 REINFORCING BARS INDICATED ON DRAWINGS <br />TO BE WELDED SHALL CONFORM TO ASTM A706. REINFORCING <br />COMPLYING WITH ASTM A615(S7) MAY BE WELDED ONLY IF MATERIAL <br />PROPERTY REPORTS INDICATING CONFORMANCE WITH WELDING <br />PROCEDURES SPECIFIED IN A.W.S. D14 ARE SUBMITTED. <br />6. REINFORCING STEEL SHALL BE DETAILED (INCLUDING HOOKS AND <br />BENDS) IN ACCORDANCE WITH ACT 315 AND 318. LAP ALL <br />CONTINUOUS REINFORCEMENT AT LEAST 30 BAR DIAMETERS OR A <br />MINIMUM OF 2'-0'. PROVIDE CORNER BARS AT ALL WALL AND FOOTING <br />INTERSECTIONS. LAP CORNER BARS AT LEAST 30 BAR DIAMETERS OR <br />A MINIMUM OF 2'-0'. LAP ADJACENT MATS OF WELDED WIRE FABRIC A <br />MINIMUM OF 8" AT SIDES AND ENDS. <br />7. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185. <br />8. SPIRAL REINFORCEMENT SHALL BE PLAIN WIRE CONFORMING TO ASTM <br />A615, GRADE 60, fy=60,000 PSI. <br />9. REINFORCING PARTIALLY EMBEDDED IN CONCRETE SHALL NOT BE FIELD <br />BENT UNLESS SPECIFICALLY SO DETAILED OR APPROVED BY THE <br />CONSULTANT. <br />10. CONCRETE PROTECTION (COVER) FOR REINFORCING STEEL SHALL BE AS <br />FOLLOWS: <br />-FOOTINGS AND OTHER UNFORMED <br />SURFACES, EARTH FACE 3" <br />-FORMED SURFACES EXPOSED (M6 BARS OR LARGER) 2" <br />TO EARTH OR WEATHER (#5 BARS OR SMALLER) 1-1/2- <br />-SLABS AND WALLS (INTERIOR FACE) 3/4" <br />11. BARS SHALL BE SUPPORTED ON CHAIRS OR DOBIE BRICKS. <br />12, ANCHOR BOLTS TO CONFORM TO ASTM A307. <br />13. NON -SHRINK GROUT SHALL BE FURNISHED BY AN APPROVED <br />MANUFACTURER AND SHALL BE MIXED AND PLACED IN STRICT <br />ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED RECOMMENDATIONS. <br />GROUT STRENGTH SHALL BE AT LEAST EQUAL TO THE MATERIAL ON <br />WHICH IT IS PLACED (3,000 PSI MINIMUM). <br />14. ALL EXPANSION ANCHORS TO BE HILTI BRAND. ADHESIVE ANCHORS <br />REQUIRE TESTING TO CONFIRM CAPACITY UNLESS WAIVED BY ENGINEER <br />AND LOCAL JURISDICTION. <br />STRUCTURAL STEEL NOTES: <br />1. SHOP DRAWINGS FOR STRUCTURAL STEEL SHALL BE SUBMITTED TO AT&T AND THE <br />CONSULTANT FOR REVIEW PRIOR TO FABRICATION. <br />2. STRUCTURAL STEEL DESIGN, FABRICATION AND ERECTION (INCLUDING FIELD WELDING, <br />HIGH STRENGTH FIELD BOLTING, EXPANSION BOLTS, AND THREADED EXPANSION <br />ANCHORS) SHALL BE BASED ON THE A.I.S.C. "SPECIFICATION FOR THE DESIGN, <br />FABRICATION, AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS" LATEST EDITION. <br />SUPERVISION SHALL BE IN ACCORDANCE WITH 2O03 IBC CHAPTER 22, BY A QUALIFIED <br />TESTING AGENCY DESIGNATED BY THE CONSULTANT. THE CONSULTANT SHALL BE <br />FURNISHED WITH A COPY OF ALL INSPECTION REPORTS AND TEST RESULTS. <br />3. STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING REQUIREMENTS: <br />4. TYPE OF MEMBER <br />A. WIDE FLANGE SHAPES ASTM A992, GRADE 50 <br />A. OTHER SHAPES, PLATES, ANGLES, AND RODS ASTM A36, Fy 36 KSI <br />B. SPECIAL SHAPES AND PLATES ASTM A572, Fy 50 KSI <br />C. PIPE COLUMNS ASTM A53, Fy 35 KSI <br />D. STRUCTURAL TUBING ASTM A500, Fy 46 KSI <br />E. ANCHOR BOLTS ASTM A307 <br />F. CONNECTION BOLTS ASTM A325 TWIST -OFF -TYPE <br />5. HOT DIP GALVANIZE AFTER FABRICATION PER A123/A123M-00 ALL STEEL EXPOSED TO <br />WEATHER AND WHERE NOTED. <br />6. ALL WELDING SHALL BE IN CONFORMANCE WITH A.I.S.C. AND AWS STANDARDS AND SHALL <br />BE PERFORMED BY ANSI/AWS D1.1 CERTIFIED WELDERS USING E70 XX ELECTRODES. <br />ONLY PREQUALIFIED WELDS (AS DEFINED BY AWS) SHALL BE USED. WELDING OF GRADE <br />60 REINFORCING BARS (IF REQUIRED) SHALL BE PERFORMED USING LOW HYDROGEN <br />ELECTRODES. WELDING OF GRADE 40 REINFORCING BARS (IF REQUIRED) SHALL BE <br />PERFORMED USING E70 XX ELECTRODES. WELDING WITHIN 4" OF COLD BENDS IN <br />REINFORCING STEEL IS NOT PERMITTED. SEE REINFORCING NOTE FOR MATERIAL <br />REQUIREMENTS OF WELDED BARS. <br />7. COLD -FORMED STEEL FRAMING MEMBERS SHALL BE OF THE SHAPE, SIZE, AND GAGE <br />SHOWN ON THE PLANS. PROVIDE MINIMUM SECTION PROPERTIES INDICATED. ALL <br />COLD -FORMED STEEL FRAMING SHALL CONFORM TO THE A.I.S.S. "SPECIFICATION FOR <br />THE DESIGN OF COLD -FORMED STEEL STRUCTURAL MEMBERS.' <br />8. BOLTED CONNECTIONS SHALL USE BEARING TYPE ASTM A325 BOLTS (3/4" DIA) AND <br />SHALL HAVE A MINIMUM OF TWO BOLTS UNLESS NOTED OTHERWISE. <br />9. NON-STRUCTURAL CONNECTIONS FOR STEEL GRATING MAY USE 5/8" DIA ASTM A307 <br />BOLTS UNLESS NOTED OTHERWISE. <br />10. (UNLESS NOTED OTHERWISE). PREPARATION AND PAINTING SHALL BE IN ACCORDANCE <br />WITH THE SPECIFICATION AND IN ACCORDANCE WITH THE PAINT MANUFACTURERS WRITTEN <br />INSTRUCTIONS. <br />11. ALL WELDS TO BE 1/4" FILLET UNLESS NOTED OTHERWISE. <br />12. TOUCH UP ALL FIELD DRILLING ,WELDING AND CUT SURFACES WITH 2 COATS OF <br />GALVACON (ZINC RICH PAINT) OR APPROVED EQUAL- <br />TOWER/POLE NOTES: <br />1. VERIFICATION THAT THE EXISTING TOWER/POLE CAN SUPPORT THE PROPOSED ANTENNA <br />LOADING IS TO BE DONE BY OTHERS. <br />2. PROVIDE SUPPORTS FOR THE ANTENNA COAX CABLES TO THE ELEVATION OF ALL INITIAL <br />AND FUTURE ANTENNAS. ANTENNA COAX CABLES ARE TO BE SUPPORTED AND <br />RESTRAINED AT THE CENTERS SUITABLE TO THE MANUFACTURER'S REQUIREMENTS. <br />nog <br />STRUCTURAL DRAWINGS AND NOTES SHALL TAKE PRECEDENCE <br />OVER ALL DRAWINGS AND NOTES. <br />SPECIAL INSPECTIONS: <br />1. CONTRACTOR SHALL PROVIDE REQUIRED SPECIAL INSPECTIONS PERFORMED BY AN <br />INDEPENDENT INSPECTOR, APPROVED BY AT&T AND THE LOCAL JURISDICTION, AS <br />REQUIRED BY THE 2009 IBC SECTION 1704 WITH WASHINGTON AMENDMENTS FOR THE <br />FOLLOWING: <br />A. CONCRETE: PROVIDE SPECIAL INSPECTION PER 1704.4 <br />1. TAKE CONCRETE TEST SPECIMENS DURING THE PLACING OF STRUCTURAL <br />REINFORCING AND STRUCTURAL CONCRETE. EXTERIOR AND INTERIOR SLABS ON <br />GRADE ARE NOT STRUCTURAL ELEMENTS. <br />ii. VERIFY REINFORCING SIZE, PLACEMENT, AND GRADE. <br />B. BOLTS AND ANCHORS IN CONCRETE: <br />i. HOLDDOWN ANCHORS BOLTS: INSPECT SIZE, LENGTH, HOOK AND TIE TO <br />REINFORCING. <br />n. ADHESIVE ANCHORS: INSPECT HOLE SIZE, DEPTH, CLEANLINESS, AND <br />INSTALLATION PER MANUFACTURES RECOMMENDATIONS. <br />C. WELDING: <br />i. VISUALLY INSPECT ALL STRUCTURAL FIELD AND SHOP WELDING. <br />o. THE SPECIAL INSPECTOR NEED NOT TO BE CONTINUOUSLY PRESENT DURING <br />WELDING, PROVIDED THE MATERIALS, QUALIFICATIONS OF WELDING PROCEDURES <br />AND WELDERS ARE VERIFIED PRIOR TO THE START OF WORK; PERIODIC <br />INSPECTIONS ARE MADE OF WORK IN PROGRESS; AND A VISUAL INSPECTION <br />OF ALL WELDS IS MADE AFTER COMPLETION OR PRIOR TO SHIPMENT OF SHOP <br />WELDING. <br />2. PROVIDE SPECIAL INSPECTIONS FOR OTHER ITEMS NOTED ON DRAWINGS TO CONFIRM <br />COMPLIANCE WITH CONTRACT DOCUMENTS. <br />3. THE SPECIAL INSPECTOR SHALL PROVIDE A COPY OF THE REPORT TO THE OWNER, <br />ARCHITECT, STRUCTURAL ENGINEER, CONTRACTOR, AND BUILDING OFFICIAL <br />ABBREVIATED ROOF TOP SAFETY PROCEDURES <br />(WHEN APPLICABLE: <br />FALL PROTECTION METHODS AND EQUIPMENT ROOF TOP INSTALLATIONS. <br />1. FALL PROTECTION METHODS TO BE PER FEDERAL, STATE, LOCAL, OSHA, AT&T AND <br />OWNER REQUIREMENTS. <br />2. FOR WORK IS BEING PERFORMED WITHIN 25' OF AN UNPROTECTED ROOF EDGE, THE <br />CONSTRUCTION SUPERVISOR SHALL DESIGNATE A TRAINED SAFETY MONITOR TO OBSERVE <br />THE MOVEMENTS AND ACTIVITIES OF THE CONSTRUCTION WORKERS. <br />3. SAFETY MONITOR SHALL WARN CONSTRUCTION WORKERS OF HAZARDS (I.E., BACKING UP <br />TOWARD A ROOF EDGE, ETC.) OR UNSAFE ACTIVITIES. THE SAFETY MONITOR MUST BE ON <br />THE SAME ROOF AND WITHIN VISUAL AND VERBAL DISTANCE OF THE CONSTRUCTION <br />WORKERS. <br />4. CONSTRUCTION INVOLVING WORKERS TO APPROACH WITHIN 6' OR LESS OF AN <br />UNPROTECTED ROOF EDGE, REQUIRES WORKERS TO USE SAFETY LINE. <br />S. SAFETY LINE SHALL BE MINIMUM 1/2' DIAMETER NYLON, WITH A NOMINAL TENSILE <br />STRENGTH OF 5400 LETS. <br />6. SAFETY LINE SHALL BE ATTACHED TO A SUBSTANTIAL MEMBER OF THE STRUCTURE. <br />7. SAFETY LINE LENGTH SHALL BE SET ALLOWING CONSTRUCTION WORKER TO REACH EDGE <br />OF ROOF, BUT NOT BEYOND. <br />B. SAFETY BELTS SHALL BE WORN BY ALL CONSTRUCTION WORKERS. <br />9. MONTHLY SAFETY INSPECTION AND MAINTENANCE OF THE FALL PROTECTION EQUIPMENT <br />SHALL OCCUR BY THE SAFETY COMMITTEE REPRESENTATIVES, INCLUDING: <br />INSPECTION OF CONSTRUCTION AREA FOR HAZARDS <br />USE OF AN INSPECTION CHECKLIST <br />INTERVIEWING COWORKERS REGARDING SAFETY CONCERNS <br />REPORTING AND DOCUMENTING ANY HAZARDS <br />REPORTING HAZARDS TO THE SAFETY COMMITTEE FOR CONSIDERATION <br />POSTING RESULTS OF INSPECTION AND ANY ACTION TAKEN <br />RECEIVING AN UNBIASED REVIEW OF ONE'S OWN WORK AREA BY ANOTHER <br />COWORKER SAFETY REPRESENTATIVE <br />REFER TO ROOFTOP WORK AREA SAFETY PROTOCOL NATIONAL ASSOCIATION OF TOWER <br />ERECTORS 2000 PUBLICATION <br />REFERENCED OSHA REGULATION/STANDARDS SHALL BE REVIEWED BY TOWER ERECTORS, <br />EQUIPMENT INSTALLERS, AND TOWER/ROOF TOP CONTRACTORS/SUBCONTRACTORS <br />29 CFR 1926.500 - SCOPE, APPLICATION, AND DEFINITIONS <br />29 CFR 1926.501 - DUTY TO HAVE FALL PROTECTION <br />19 CFR 1926.502 - FALL PROTECTION SYSTEMS CRITERIA AND PRACTICES <br />SYMBOLS AND ABBREVIATIONS <br />A/C <br />AIR CONDITIONING <br />HORZ <br />HORIZONTAL <br />A.G.L. <br />ABOVE FINISH GRADE <br />HR <br />HOUR <br />APPROX <br />APPROXIMATELY <br />HT <br />HEIGHT <br />HVAC <br />HEATING <br />BLDG <br />BUILDING <br />VENTILATION <br />ELK <br />BLOCKING <br />AIR CONDITIONING <br />CLG <br />CEILING <br />ID <br />INSIDE DIAMETER <br />CLR <br />CLEAR <br />IN <br />INCH <br />CONC <br />CONCRETE <br />INFO <br />INFORMATION <br />CONST <br />CONSTRUCTION <br />INSUL <br />INSULATION <br />CONT <br />CONTINUOUS <br />INT <br />INTERIOR <br />IBC <br />INTERNATIONAL <br />DBL <br />DOUBLE <br />BUILDING CODE <br />DIA <br />DIAMETER <br />DIAG <br />DIAGONAL <br />LBS <br />POUNDS <br />ON <br />DOWN <br />DET <br />DETAIL <br />MAX <br />MAXIMUM <br />DWG <br />DRAWING <br />MECH <br />MECHANICAL <br />MTL <br />METAL <br />EA <br />EACH <br />MFR <br />MANUFACTURE <br />ELEV <br />ELEVATION <br />MGR <br />MANAGER <br />ELEC <br />ELECTRICAL <br />MIN <br />MINIMUM <br />EQ <br />EQUAL <br />MISC <br />MISCELLANEOUS <br />EQUIP <br />EQUIPMENT <br />EXT <br />EXTERIOR <br />NA <br />NOT APPLICABLE <br />NIC <br />NOT IN CONTRACT <br />FIN <br />FINISH <br />NTS <br />NOT TO SCALE <br />FLUOR <br />FLOURESCENT <br />FLR <br />FLOOR <br />OC <br />ON CENTER <br />FT <br />FOOT <br />OD <br />OUTSIDE DIAMETER <br />GA <br />GAUGE <br />GALV <br />GALVANIZED <br />GC <br />GENERAL CONTRACTOR <br />GRND <br />GROUND <br />GYP SO <br />GYPSUM WALL BOARD <br />- T - <br />TELEPHONE <br />P - <br />POWER <br />G- <br />GROUND WIRE <br />-COAX- <br />COAXIAL CABLE <br />® <br />ANTENNA <br />CE <br />CENTERLINE <br />(E) <br />EXISTING <br />(N) <br />NEW <br />[�] <br />DETAIL NUMBER <br />x- <br />SHEET NUMBER <br />PLYWD PLYWOOD <br />PROD PROJECT <br />PROP PROPERTY <br />PT PRESSURE TREATEE <br />RED REQUIRED <br />RM ROOM <br />RO ROUGH OPENING <br />SHT <br />SHEET <br />Sim <br />SIMILAR <br />SPEC <br />SPECIFICATION <br />SF <br />SQUARE FOOT <br />SS <br />STAINLESS STEEL <br />STL <br />STEEL <br />STRUCT <br />STRUCTURAL <br />STD <br />STUD <br />SUSP <br />SUSPENDED <br />THRU THROUGH <br />TNNG TINNED <br />TYP TYPICAL <br />UNO UNLESS NOTED <br />OTHERWISE <br />VERT VERTICAL <br />VIF VERIFY IN FIELD <br />W/ WITH <br />W/0 WITHOUT <br />WP WATER PROOF <br />a� <br />N <br />u_ <br />Q7 <br />a <br />4-d <br />Z <br />66 0 <br />0 <br />L) <br />aZi <br />W `co <br />fn <br />in <br />w'n .°>>' <br />' <br />V i <br />(((c <br />CAMP+ <br />ASSOCIATES <br />1-1 40TH -- SUITE 304 <br />LYNN.., WA 98036 <br />PHONE: (425) 740-6392 <br />FAX: (425) 224-1614 <br />W W W.CAMPASSOC.COM <br />DATE: 01/21/16 <br />DRAWN BY: EAT <br />CHECKED BY: PIN <br />I REVISIONS I <br />REGISTERED <br />l ARCHI ECT <br />uL I <br />HINGTON <br />OF AS <br />O1/21/2016 <br />SN91-SOUTH EVERETT <br />209 EAST CASINO ROAD <br />EVERETT, WA 98208 <br />LE <br />GENERALNOTES <br />SHEET NUMBER <br />G-2.0 <br />JOB No. SN91 // <br />