My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
915 N BROADWAY WSU CAFE 2017-11-03
>
Address Records
>
N BROADWAY
>
915
>
WSU CAFE
>
915 N BROADWAY WSU CAFE 2017-11-03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/3/2017 3:58:23 PM
Creation date
10/13/2017 3:47:29 PM
Metadata
Fields
Template:
Address Document
Street Name
N BROADWAY
Street Number
915
Tenant Name
WSU CAFE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• 9M-9 - I:z <br /> Design Gross Properties ( Effective Prop.(33 ksi) Effective Prop.(50 ksi)- Torsional Properties <br /> Section Thickness i Area Weight Ix Sx Rx ly Ry ke Sxe Ma Vag Ixe Sxe Ma Vag Jx1000 Cw Xo m Ro 8 <br /> (in) a (inj (Ib/ft) (in') (in') (in) (in') (in) (in`) (in') (in-k) (lb) (in') (in') (in-k) (lb) (in') (ink (in) (in) (in) <br /> 6DOT150-43 0.0451 0.405 1.38 2.072 0.673 2.261 0.073 0.424 1.890 0.474 9.36 1377 - - - - 0.275 0.504 -0.680 0.437 2.398 0.920 <br /> 60OT150-54 0.0566 0.509 1.73 2.611 0.843 2.266 0.091 0.422 2.473 0.689 13.62 2728 2.400 0.609 18.24 2728 0.543 0.632 -0.675 0.434 2.401 0.921 <br /> 600T150-68 0.0713 0.641 2.18 3.309 1.059 2.273 0.113 0.419 3.262 0.963 19.03 4347 3.162 0.891 26.68 5350 1.086 0.797 -0.669 0.430 2.406 0.923 <br /> 60OT150-97 0.1017 0.913 3.11 4.778 1.504 2.288 0.156 0.413 4.778 1.504 29.71 7359 4.778 1.444 43.23 10885 3.148 1.138 -0.656 0.421 2.415 0.926 <br /> 60OT150-118 0.1242 1.115 3.79 5.886 1.829 2.298 0.186 0.409 - - - 5.886 1.829 61.64 13539 5.730 1.389 -0.647 0.415 2.422 0.929 <br /> 60OT200-33 0.0346 0.346 1.18 1.913 0.622 2.352 0.126 0.604 1.542 0.333 6.59 622 - - - 0.138 0.847 -1.048 0.655 2.645 0.843 <br /> 60OT200-43 0.0451 0.451 1.53 2.494 0.809 2.353 0.163 0.602 2.076 0.565 11.16 1377 - - - - 0.305 1.098 -1.044 0.652 2.643 0.844 <br /> 60OT200-54 0.0566 0.565 1.92 3.145 1.015 2.359 0.203 0.600 2.759 0.759 15.00 2728 2.641 0.717 21.48 2728 0.604 1.381 -1.038 0.649 2.646 0.846 <br /> 60OT200-68 0.0713 0.712 2.42 3.990 1.277 2.367 0.254 0.597 3.696 1.034 20.42 4347 3.540 0.973 29.12 5350 1.206 1.746 -1.031 0.644 2.650 0.849 <br /> 60OT200-97 0.1017 1.015 3A5 5.773 1.816 2.385 0.354 0.591 5.758 1.667 32.95 7359 5.558 1.568 46.94 10885 3.499 2.510 -1.016 0.635 2.659 0.854 <br /> 600 T200-118 0.1242 1.239 4.21 7.122 2.214 2.398 0.426 0.586 - - - - 7.122 2.051 61.42 13539 6.369 3.083 -1.006 0.628 2.665 0.858 <br /> 60OT250-43 0.0451 0.496 1.69 2.916 0.946 2.425 0.303 0.781 2.269 0.563 11.13 1377 - - 0.336 2.004 -1.436 0.878 2.925 0,759 <br /> 60OT250-54 0.0566 0.622 2.12 3.678 1.187 2.432 0.377 0.779 3.014 0.794 15.68 2728 2.881 0.732 21.92 2728 0.664 2.523 -1.430 0.874 2.927 0.761 <br /> 60OT250-68 0.0713 0.783 2.67 4.670 1.495 2.442 OA72 0.776 4.065 1.085 21.45 4347 3.871 1.017 30.46 5350 1.327 3.198 -1.422 0.869 2.930 0.764 <br /> 60OT250-97 0.1017 1.117 3.80 6.767 2.129 2.462 0.662 0.770 6.441 1.775 35.08 7359 6.158 1.656 49.58 10885 3.849 4.616 -1.406 0.859 2.938 0.771 <br /> 60OT250-118 0.1242 1.363 4.64 8.359 2.598 2.477 0.798 0.765 8.306 2.343 46.30 8936 7.990 2.188 65.51 13539 7.008 5.686 -1.394 0.852 2.943 0.776 <br /> 80OT125-33' 0.0346 0.363 1.24 2.895 0.711 2.824 0.036 0.313 2.441 0.407 8.03 465 - - - - 0.145 0.456 -0.439 0.294 2.875 0.977 <br /> 80OT12543 0.0451 0.473 1,61 3.773 0.924 2.824 0.046 0.311 3.484 0.640 12.65 1030 - - - 0.321 0.589 -0,436 0.292 2.874 0.977 <br /> 80OT125-54 0.0566 0.594 2.02 4.745 1.158 2.827 0.057 0.309 4.668 0.940 18.58 2039 4.426 0.824 24.66 2039 0.634 0.735 -0.432 0.289 2.877 0.977 <br /> 80OT125-68 0.0713 0.748 2.54 5.998 1.454 2.833 0.070 0.306 5.998 1.356 26.80 4087 5.956 1.216 36.39 4087 1.267 0.920 -0.427 0.286 2.881 0.978 <br /> 80OT125-97 0.1017 1.066 3.63 8.613 2.062 2.843 0.096 0.301 8.613 2.062 40.74 8843 8.613 2.062 61.72 10885 3.674 1.296 -0.417 0.279 2.889 0.979 <br /> 80OT125-118 0.1242 1.301 4.43 10.569 2.506 2.850 0.114 0.297 - - 10.569 2.506 86.21 16235 6,688 1.567 -0.410 0.274 2.895 0.980 <br /> 80OT150-33' 0.0346 0.380 1.29 3.180 0.781 2.891 0.060 0.397 2.569 0.414 8.18 465 - - - - 0.152 0.751 -0.588 0.388 2.977 0.961 <br /> 80OT150-43 0.0451 0.496 1.69 4.144 1.015 2.891 0.077 0.395 3.689 0.655 12.95 1030 - 0.336 0.972 -0.584 0.386 2.976 0.961 <br /> 80OT150-54 0.0566 0.622 2.12 5.214 1.272 2.896 0.096 0.393 4.976 0.969 19.15 2039 4.692 0.844 25.27 2039 0.664 1.215 -0.580 0.383 2.979 0.962 <br /> 80OT150-68 0.0713 0.783 2.67 6.594 1.599 2.902 0.119 0.390 6.527 1.412 27.91 4087 6.361 1.255 37.58 4087 1.327 1.526 -0.575 0.379 2.984 0.963 <br /> 80OT150-97 0.1017 1.116 3.80 9.479 2.269 2.914 0.165 0.384 9.479 2.269 44.83 8843 9.479 2,192 65.62 10885 3.849 2.162 -0.564 0.372 2.993 0.965 <br /> 80OT150-118 0.1242 1.363 4.64 11.641 2.760 2.923 0.197 0.380 - - - 11.641 2.760 93.00 16235 7.008 2.627 -0.555 0.366 2.999 0.966 <br /> 80OT200-331 0.0346 0.415 1.41 3.749 0.921 3.005 0.135 0.571 2.788 0.424 8.37 465 - 0.166 1.638 -0.917 0.589 3.194 0.918 <br /> 80OT200 13 0.0451 0.541 1.84 4.887 1.197 3.006 0.175 0.569 4.043 0.676 13.35 1030 - - - 0.367 2.124 -0.913 0.587 3.193 0.918 <br /> BOOT200-54 0.0566 0.679 2.31 6.152 1.501 3.011 0.218 0.567 5.505 1.009 19.93 2039 5.149 0.871 26.09 2039 0.725 2.664 -0.908 0.584 3.196 0.919 <br /> 80OT200-68 0.0713 0.854 2.91 7.786 1.888 3.019 0.272 0.564 7.306 1.490 29.45 4087 7.051 1.310 39.22 4087 1.448 3.357 -0,902 0.580 3.201 0.921 <br /> 80OT200-97 0.1017 1.218 4.15 11.212 2.683 3.034 0.379 0.558 11.176 2.491 49.22 8843 10.833 2.347 70.27 10885 4.200 4.792 -0.869 0.571 3.210 0.923 <br /> 80OT200-118 0.1242 1.487 5.06 13.785 3.269 3.045 0.455 0.553 - - - 13.785 3.059 91.59 16235 7.646 5.854 -0.879 0.565 3.217 0.925 <br /> 80OT250-43 0.0451 0.586 1.99 5.629 1.380 3.100 0.326 0.746 4.593 0.739 14.60 1030 - - - - 0.307 3.877 -1.274 0.801 3.433 0.862 <br /> 80OT250-54 0.0566 0.735 2.50 7.090 1.730 3.106 0.407 0.744 5.948 1.193 23.57 2039 5.815 0.959 28.71 2039 0.785 4.870 -1.268 0.798 3.436 0.864 <br /> BOOT250-68 0.0713 0.926 3.15 8.978 2.177 3.114 0.509 0.741 7.917 1.648 32.57 4087 7.588 1.560 46.72 4087 1.569 6.151 -1.261 0.793 3.441 0.866 <br /> 800T250-97 0.1017 1.320 4,49 12.944 3.098 3,132 0.713 0.735 12.361 2.641 52.19 8843 11.872 2.487 74.47 10885 4.550 8,818 -1.247 0.784 3.450 0.869 <br /> 80OT250-118 0.1242 1.611 5.48 15.930 3.777 3.144 0.860 0.731 15.822 3.448 68.14 12009 15.272 3.248 97.26 16235 8.285 _1_0.807__-1.236 0.777 3.457 0.872 <br /> 1000T125-431 0.0451 0.563 1.92 6.630 1.305 3.431 0.047 0.290 5.886 0.819 16.19 822 - - - - 0.382 0.973 -0.379 0.259 3.464 0.988 <br /> 1000T125-54 0.0566 0.707 2.41 8.333 1.634 3.434 0.059 0.288 7.960 1.216 24.03 1628 7.479 1.055 31.59 1628 0.755 1.212 -0.376 0.256 3.466 0.986 <br /> 1000T125-68 0.0713 0.890 3.03 10.522 2.053 3.438 0.073 0.286 1OA52 1.781 35.19 3261 10.155 1.575 47.15 3261 1.508 1.515 -0.372 0.253 3.470 0.989 <br /> 1000T125-97 0.1017 1.269 4.32 15.077 2.912 3.447 0.100 0.280 15.077 2.907 57.44 8843 15.077 2.753 82.42 9507 4.375 2.123 -0.363 0.247 3.477 0.989 <br /> 1000T125-118 0.1242 1.549 5.27 18.471 3.540 3.453 0.118 0.276 - - - - 18.471 3.535 105.85 16235 7.966 2.558 -0.357 0.243 3.482 0.990 <br /> 1000T150-431 0.0451 0.586 1.99 7.207 1.419 3.507 0.080 0.370 6.195 0.837 16.54 822 - - - - 0.397 1.612 -0.513 0.345 3.564 0.979 <br /> 1000T150-54 0.0566 0.735 2.50 9.061 1.777 3.511 0.100 0.368 8.430 1.249 24.69 1628 7.880 1.079 32.29 1628 0.785 2.013 -0.509 0.342 3.567 0.980 <br /> 1000T150-68 0.0713 0,926 3.15 11.445 2.233 3.516 0.124 0.366 11.342 1.846 36.48 3261 10.774 1.621 48.53 3261 1.569 2.522 -0.505 0.339 3.571 0.980 <br /> 1000T150-97 0.1017 1.320 4.49 16.413 3.170 3.526 0.171 0.360 16.413 3.165 62.54 8843 16.413 2.902 86.90 9507 4.550 3.557 -0.495 0.332 3.579 0.981 <br /> 1000T150-118 0.1242 1.611 5.48 20.121 3.857 3.534 0.204 0.356 - - - - 20.121 3.852 115.32 16235 8.285 4.307 -0.488 0.328 3.585 0.982 <br /> 1000T200431 0.0451 0.631 2.15 8.361 1.646 3.640 0.183 0.539 6.722 0.861 17.01 822 - - - 0.428 3.540 -0.813 0.534 3.769 0.953 <br /> 1000T200-54 0.0566 0.792 2.69 10.516 2.062 3.645 0.228 0.537 9.231 1.295 25.60 1628 8.560 1.111 33.26 1628 0.845 4.434 -0.809 0.531 3.772 0.954 <br /> 1000T200-68 0.0713 0.997 3.39 13.292 2.594 3.651 0.284 0.534 12.551 1.936 38.26 3261 11.820 1.684 50.42 3261 1.690 5.576 -0.803 0.527 3.776 0.955 <br /> 1000T200-97 0.1017 1.422 4.84 19.087 3.686 3.664 0.397 0.528 19.031 3.427 67.72 8843 18.583 3.081 92.25 9507 4.901 7.924 -0.791 0.519 3.786 0.956 <br /> 1000T200-118 0.1242 1.736 5.91 23.422 4.489 3.674 0.476 0.524 - - - - 23.422 4.208 125.99 16235 8.924 9.649 -0.783 0.514 3.793 0.957 <br /> 1000T250-431 0.0451 0.676 2.30 9.515 1.873 3.752 0.344 0.713 7.172 0.376 17.32 822 - - - - 0.458 6.477 -1.147 0.737 3.987 0.917 <br /> 1000T250-54 0.0566 0.848 2.89 11.972 2.348 3.577 0.429 0.711 9.913 1.326 26.20 1628 9.141 1.132 33.89 1628 0.906 8.125 -1.142 0.734 3.990 0.918 <br /> 1000T250-68 0.0713 1.068 3.64 15.138 2.954 3.764 0.536 0.708 13.578 1.997 39.46 3261 12.708 1.726 51.68 3261 1,811 10.240 -1.135 0.730 3.995 0.919 <br /> 1000T250-97 0.1017 1.523 5.18 21.760 4.203 3.780 0.751 0.702 20.871 3.596 71.05 8843 20.254 3.201 95.84 9507 5.252 14.617 -1.122 0.721 4.005 0.921 <br /> 1000T250-118 0.1242 1.860 6.33 26.723 5.122 3.791 0.905 0.698 26.538 4.721 93.29 13189 25.721 4.422 132.38 16235 9.562 17.858 -1.112 0.715 4.012 0.923 <br /> 120OT125-541 0.0566 0.820 2.79 13.335 2.186 4.033 0.060 0.271 12.296 1.491 29.47 1354 11.460 1.286 38.51 1354 0.876 1.820 -0.333 0.230 4,055 0.993 <br /> 120OT125-68 0.0713 1.033 3.51 16.826 2.747 4.036 0.074 0.268 16.246 2.206 43.60 2713 15.686 1.934 57.90 2713 1.750 2.270 -0.329 0.227 4.059 0.993 <br /> 120OT125-97 0.1017 1.472 5.01 24.078 3.897 4.044 0.102 0.263 24.078 3.690 72.92 7902 23.751 3.442 103.06 7902 5.076 3.171 -0.322 0.222 4.065 0.994 <br /> 120OT125-118 0.1242 1.798 6.12 29.472 4.740 4.049 0.121 0.260 - - - - 29.472 4.490 134.44 14434 9.243 3.812 -0.316 0.218 4.070 0.994 <br /> 120OT150-541 0.0566 0.848 2.89 14.378 2.357 4.117 0.103 0.348 12.962 1.530 30.23 1354 12.020 1.313 39.31 1354 0.906 3.033 -0.454 0.310 4.156 0.988 <br /> 120OT150-68 0.0713 1.068 3.64 18.148 2.963 4.121 0.127 0.345 17.568 2.281 45.08 2713 16.566 1.987 59.48 2713 1.810 3.795 -0.450 0.307 4.160 0.988 <br /> 12DOT150-97 0.1017 1.523 5.18 25.987 4.206 4.130 0-176 0.340 25.987 3.996 78.97 7902 25.719 3.616 108.27 7902 5.252 5.335 -0.441 0.301 4.168 0.989 <br /> 120OT150-118 0.1242 1.860 6.33 31.825 5.119 4.137 0.210 0.336 - - - - 31.825 4.865 145.66 14434 9.562 6.444 -0.435 0.296 4.173 0.989 <br /> 120OT200-54' 0.0566 0.905 3.08 16.464 2.699 4.265 0.236 0.510 14.078 1.582 31.26 1354 12.962 1.350 40.41 1354 0.966 6.714 -0.730 0.487 4.357 0.972 <br /> 120OT200-68 0.0713 1.140 3.88 20.791 3.395 4.271 0.294 0.508 19.277 2.383 47.09 2713 18.026 2.058 61.62 2713 1.931 8.431 -0.725 0.483 4.362 0.972 <br /> Web height-to-thickness ratio exceeds 200. Web stiffeners are required at all support points and concentrated loads. <br /> 'Allowable moment includes cold work offorming. <br /> 'Where web height-to-thickness ratio exceeds 260 or flange width-to-thickness ratio exceeds 60,effective properties are not calculated.See A1515100 Section 81.Application ofthese <br /> products in a non-composite design shall be appro ved by a design professional. <br /> See Table Notes on page.1S. <br /> Complies With 2009,2012 and 2015 IBC www.SSMA.com 17 <br />
The URL can be used to link to this page
Your browser does not support the video tag.