Laserfiche WebLink
• • <br /> LX Series <br /> MYORK' PHE4-14 SEER Single Pkg. R-410A Heat Pump <br /> Project Name: MCCAULY&ASSOCIATES Unit Model#: PHE4B3621 <br /> Quantity: 1 Tag#:1 IN STOCK IN System: PHE4133621 <br /> TIGARD AS OF TODAY <br /> Cooling Performance __ -. <br /> Total capacity 37.1 MBH <br /> Sensible capacity 26.5 MBH <br /> Ambient DB temp. 95.0 °F Z <br /> Entering DB temp. 80.0 °F `� <br /> Entering WB temp. 67.0 °F ll � �,^u <br /> Leaving DB temp. 59.6 °F `'�� = =r <br /> Leaving WB temp. 57.2 °F +—r <br /> Power input 3.00 kW 1 <br /> Refrigerant <br /> Refrigerant type R-41 OA f <br /> Heat Pump Performance n ` <br /> Heating output capacity(Max) 35.8 MBH <br /> Ambient DB temp. 47 °F 4 <br /> Leaving DB temp. 87.6 °F <br /> Air temp.rise 27.6 °Ft <br /> Power input 2.47 kW <br /> Heating Performance <br /> Entering DB temp. 60 °F 3 Ton <br /> Heating output capacity(Max) 29.9 MBH • LX Series Packaged Units are Manufactured at an ISO 9001 Registered <br /> Nominal electric heat 8.8 kW Facility and Each Rooftop is Completely Computer-Run Tested Prior To <br /> Installed Field Shipment <br /> Power input 8.80 kW <br /> Supply air 1200 CFM Unit Features <br /> Leaving DB temp. 83.1 °F . Unit Cabinet is Constructed of G-90 Galvanized Steel with a Powder Paint <br /> Air temp.rise 23.1 °F Coating at 1000 Hour Salt Spray Tested <br /> Supply Air Blower Performance • Bottom and Side Electrical and Gas Utility Connections <br /> Supply air 1200 CFM • Easy Access to All Components <br /> Ext.static pressure 0.46 IWG . Single Piece Water-Shed Top Cover and Drip Edge <br /> Blower speed description Medium/High . Field Convertible Duct Connections From Horizontal to Downflow Allows <br /> 4 Greater Flexibility <br /> Duct location Side y <br /> Elevation 0 ft. • Full Perimeter,Removable Base Rails with Built in Rigging and Access <br /> Drive type DIRECT Provisions <br /> Electrical Data • Non-Corrosive Condensate Pan Internally Sloped to Meet Strict <br /> Power supply 230-1-60 Requirements of ASHRAE 62-89 Indoor Quality Standard <br /> Unit min circuit ampacity 74.2 Amps • Single Speed Scroll Compressor <br /> Unit max over-current protection 80 Amps • Compressor is Internally Protected Against High Pressure and Temperature <br /> Dimensions&Weight • Standard Cooling Operation Down to 45 F <br /> Hgt 49 in. Len 51 in. Wth 46 in. • Variable Speed Direct Drive High Static Motor and Slide-out Blower <br /> Weight with factory installed options 448 lbs. Assembly <br /> Note: Please refer to the tech guide for listed maximum static pressures Warranty <br /> ® h • Standard one(1)year limited parts warranty. <br /> A AMERICAN . <br /> QUALITY • Standard five(5)year limited compressor warranty. <br /> SI•� GoorlHousekeeping�, <br /> _ Pronrlset <br /> Unitary Sales Tool v1.5.9.0 • Information is subject to change without notice.Check local code Printed 10/04/201 <br />