Permit#: M1608-102 <br /> (1)24 Port Patch Panel . Ow eddress:�6SE EVRETT MALL WAY STE UEGEREEV REIT HOLDINGS LLC <br /> 0 <br /> Supplied by Lochner <br /> Installed by Network Cabling Contractor Tenant: LOCHNER <br /> Use RU 43 App.Date: 8/31/2016 <br /> 3/4"x 4'x 4' Plywood Mounted <br /> W <br /> To Wall Starting From Back Wall — all of Server Room Proposed Use: COMMERCIAL <br /> PDescription: INSTALL 1 EXHAUST FAN IN SERVER ROOM- <br /> Painted White Chatsworth Vertical Cable Management <br /> Installed by General Contractor Supplied by Lochner TI FOR TENANT-LOCHNER <br /> Installed by Network Cabling Contractor ti <br /> Review By: / Date: " <br /> I <br /> ffice Set Job Site Set Fire/Planning Set <br /> Front Wall _ <br /> of Server Room <br /> - uemarcatlon Extensions ' u <br /> Of Service Providers ° ❑ <br /> Use Ports 1 -4 5 ❑ <br /> (4)20amp Dedicated Circuts ❑D❑❑❑❑ ❑❑❑O0 12 13 14 15 16 17❑ 0000aE] 000000 6 El <br /> Use Orange, Nema 5-20r Data and Label Patch Panel <br /> Front of Server Rack Recepticals Installed By Demarcati n ❑❑❑❑❑❑❑ ❑❑❑❑❑❑❑❑ ❑❑❑❑❑❑❑ Lochner Suite 130 7 ❑ <br /> Electrical Contractor Cable Runs e ❑ <br /> Run(4)Demarcation Terminate in Suite 130 9 ❑ <br /> Extensiond From Building Server Room 10❑ <br /> Wire Closet to Ports 20-24 Using Lower Patch Panel 11❑ <br /> 4'0"From Front Wall of � � On Bottom Patch Panel. RU 43 <br /> Ports 20-24 12❑ <br /> Server Room to D <br /> Front of Rack v <br /> Demarcation x I s <br /> Server Rack E <br /> From Building Wire Closet <br /> - Not To Scale U) <br /> Y <br /> Server Room Rack Location 4'0"From Back Wall of <br /> South East Wall Elevation Server Room to Center Cabling Installation Into Server Room Racks W 2I <br /> Not To Scale of(4)20 AMP Not To Scale = O <br /> Dedicated Circuits U Z <br /> a <br /> ----- — --------------------� p Q <br /> I J yf <br /> Install new data runs from <br /> -- locations shown Terminating in \ D I U <br /> Server Room 5 ❑ I = <br /> EXIST. 0 j <br /> OFFICE <br /> 102 I W <br /> EXIST. I E <br /> NEW OFFICE I O <br /> BREAK RM 103 I O <br /> I 101 <br /> 3/4"x 4'x 4'Plywood Mounted I 1D <br /> E. To Wall Starting From Back Wall I � - OFFICE <br /> Front Wall TrpI Z <br /> Painted White <br /> . <br /> Installed by General Contractor of Server Room \ -5 -_- 92_5' -----__ ` 10 I <br /> (4)20amp Dedicated Circuts I ` OFFICE ❑ j <br /> - <br /> Use Orange, Nema 5-20r tos <br /> Recepticals Installed By I �k�i �( jl� r OFFICE R <br /> Electrical Contractor >>' r_1 087 �`- so'-2'-- I EC 0z22io s <br /> ❑ OPEN DAu <br /> 4'0" From Back Wall of OFFICE i <br /> Server Room to Center - 5 los <br /> E of(4)20 AMP I SERVER 7yp, 2D I REC 0727201c, <br /> x Dedicated Circuits I 107 <br /> Server Rack <br /> K I <br /> I Location of(4)20amp Dedicated Circuits. x <br /> s ------.- I Orange Color 520-r Receptacles. <br /> I < Location of Server Rack i -- <br /> m ' <br /> y <br /> IA__ <br /> \ Y^ � _ <br /> E 12'-10" ----------------------- ---� ----------- ---- <br /> Server Room Floor Plan Suite Floor Plan (�■ <br /> Not To Scale al <br /> 0 <br />