|
• • • • • J1 Ml • •
<br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised August 2016
<br /> Project Title: HearUSA-Edmonds,WA Date 2/14/2017
<br /> Calculation Addition- Addition g �.
<br /> O O O or Er-
<br /> ,in *D .p , t
<br /> NOTE s stand alone +existing Area LEM
<br /> O Spaces where<50%of 0 Spaces where>_50%of O
<br /> luminaires are replaced luminaires are replaced
<br /> LPA G Standard O Additional Efficiency Package Option O U
<br /> FEB 2017
<br /> )b
<br /> Calculation C406.3 Reduced Interior Lighting Power
<br /> To comply with C406.3,the Proposed LPD shall be 25%lower than the Target LPA. 6`11TY OF E V E R E TT
<br /> Type Refer to C406.3 for additional requirements. Permit Sery1Ces
<br /> Maximum Allowed Lighting Wattage NOTE'
<br /> Location(plan#, Ceiling Gross Interior Allowed Wafts Allowed
<br /> room#) Space Type Height NOTE 2 Area in ft2 Wafts per ft2 (watts/ft2 x area)
<br /> E-1,Rm 1 Lobby:all other 10 170 0.720 122
<br /> E-1,Rm 2 Office:Open plan 10 140 0.796 111
<br /> E-1,Rm 3 Office:Open plan 10 93 0.796 -
<br /> E-1,Rm 4 Office:Enclosed 10 203 0.908 184
<br /> E-1,Rm 5 Office:Enclosed 10 133 0.908 121
<br /> E-1,Rm 6 Lounge/breakroom:all other 10 164 0.580 95
<br /> E-1,Rm 7 Restroom:all other 10 53 0.780 41
<br /> E-1,Rm 8 Corridor:all other 1 10 232 0.530 1 123
<br /> E-1,Rm 9 Istorage room 1 10 18 0.500 19
<br /> Total Area 1206
<br /> Retail Display Allowance from LTG-INT-DISPLAY
<br /> Lobby Art/Exhibit Display Allowance from LTG-INT-DISPLAY NOTE 8� Allowed Watts 882
<br /> Proposed Lighting Wattage"ole 3
<br /> Location(plan#, Number of Watts/ Wafts
<br /> room#) Fixture Description NOTE 4,5,6 Fixtures Fixture NOTE 7 Proposed
<br /> E-1,Rm 1 New-iBright Direct Kit,LED,0-10V Dimming,120VAC 2 40 80
<br /> E-1,Rm 2 New-iBright Direct Kit,LED,0-10V Dimming,120VAC 2 40 80
<br /> E-1,Rm 3 New-iBright Direct Kit,LED,0-10V Dimming,120VAC 2 40 80
<br /> E-1,Rm 4 New-iBright Direct Kit,LED,0-10V Dimming,120VAC 2 40 80
<br /> E-1,Rm 5 New-iBright Direct Kit,LED,0-10V Dimming,120VAC 2 40 80
<br /> E-1,Rm 6 New-iBright Direct Kit,LED,0-10V Dimming,120VAC 2 40 80
<br /> E-1,Rm 7 New-iBright Direct Kit,LED,0-10V Dimming,120VAC 1 40 40
<br /> E-1,Rm 8 New-iBright Direct Kit,LED,0-10V Dimming,120VAC 3 40 120
<br /> E-1,Rm 9 New-Fluorecent Bulb,13W,120VAC 1 13 13
<br /> Proposed Retail Display Lighting from LTG-INT-DISPLAY
<br /> Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Wattsl 653
<br /> Interior Lighting Power Allowance COMPLIES
<br /> Note 1-List all unique space types per Table C405.4.2(2)that occur in the project scope.Select space type category per from drop down menu.
<br /> Note 2-Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2),Footnotes d thru f.
<br /> Note 3-List all proposed lighting Fixtures including exempt lighting equipment and existing-to-remain fixtures.
<br /> Note 4-For proposed Fixture Description,indicate fixture type,lamp type(e.g. T-8),number of lamps in the fixture,and ballast type(if included).For
<br /> track lighting,list the length of the track(in feet)in addition to the fixture,lamp,and ballast information.
<br /> Note 5-For lighting equipment eligible for exemption per C405.4.1,note exception number and leave Watts/Fixture blank.
<br /> Note 6-Existing-to-remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures Identify as existing
<br /> in fixture description.
<br /> Note 7-For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source.For
<br /> luminaires with screw-in lamps,enter the manufacturer's listed maximum input wattage of the fixture(not the lamp wattage).For low voltage
<br /> lighting,enter the wattage of the transformer.For line voltage track/busway systems,enter the larger of the attached luminaire wattage or 50
<br /> watts/lineal foot,or enter the wattage limit of permanent current limiting device.
<br /> Note 8-Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage.
<br /> Note 9-Calculation Area Details:
<br /> A�
<br />
|