My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7601 EVERGREEN WAY HEAR USA 2017-10-20
>
Address Records
>
EVERGREEN WAY
>
7601
>
HEAR USA
>
7601 EVERGREEN WAY HEAR USA 2017-10-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/20/2017 9:30:23 AM
Creation date
10/20/2017 9:30:17 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
7601
Tenant Name
HEAR USA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised August 2016 <br /> Project Title: HearUSA-Edmonds,WA Date 2/14/2017 <br /> The following information is necessary to check a permit application for compliance with the lighting,motor,and electrical requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> Applicability Location in Building epa men <br /> (yes,no,na) Code Section Component Compliance information required in permit documents Documents Notes <br /> LIGHTING CONTROLS <br /> Lighting controls, For all lighting fixtures,indicate lighting control method s , <br /> Yes C405.2 I s <br /> general for spaces and lighting zone(s)served,or exception tak <br /> Luminaire level Indicate on plans all fixtures provided with LLLC in lieu o <br /> Yes C405.2 lighting controls C405.2 lighting controls;provide description of control E-1 <br /> LLLC ca abilities and performance parametersPPR <br /> For permanently installed lighting fixtures in dwelling unit <br /> NA C405.1 Lighting in dwelling indicate lighting control method on plans for spaces and �` RET <br /> rT <br /> units lighting zone(s)served,or demonstrate compliance with highC I 1 OF EV R r <br /> efficacy exception darmit c ('� <br /> C405.2.3 Indicate on plans the method of manual lighting control(wheth r <br /> C405.2.1.1 combined with occupancy sensor,automatic light reduction, <br /> Yes C405.2.2.2 Manual controls daylight responsive or specific application controls),location of E-1 <br /> C405.2.4 manual control device and area or specifice application it <br /> C405.2.5 serves <br /> C405.2.2.1 Manual interior Indicate on plans which method of manual 50%lighting load <br /> Yes C405.2.2.2 lighting controls reduction is provided,or whether lighting load is reduced via E-1 <br /> C405.2.3 occupancy sensors or daylight responsive controls <br /> Indicate on plans the method of automatic shut-off control <br /> during unoccupied periods(occupancy sensor or time switch) E-1 <br /> Yes C405.2.2 Method of automatic for all lighting zones; <br /> shut-off control Indicate locations where automatic shutoff is provided by other <br /> methods(occupancy sensor or digital timer switch)or which E-1 <br /> time switch control exception applies <br /> Indicate on plans the spaces served by occupancy sensors; E-1 <br /> Yes C405.2.1 Occupancy sensor Indicate whether occupancy sensor controls are configured to <br /> C405.2.1.1 controls be manual-on,automatic 50%-on,or serve a space eligible for <br /> automatic 100%-on per exception <br /> Occupancy sensor Indicate aisleways and open areas in warehouse spaces <br /> NA C405.2.1.2 controls- provided with occupancy sensor controls that reduce lighting <br /> warehouses power by 50% <br /> NA C405.2.6 Digital timer switch Indicate required digital timer switch control function when <br /> control is used <br /> C405.2.2.1 Automatic time Indicate locations of override switches on plans and the lighting <br /> switch controls zones served,include areas .ft. <br /> Indicate primary and secondary sidelight daylight zone areas on E-1 <br /> plans,include sq.ft.; <br /> C405.2.4.2 Daylight zones- Indicate toplight daylight zone areas on plans,include s .ft.; <br /> Yes For small vertical fenestration assemblies(rough opening less <br /> C405.2.4.3 Sidelight and toplight than 10 percent of primary daylight zone)where daylight <br /> responsive controls are not required,provide fenestration area <br /> to daylight zone calculation(s) <br /> Indicate on plans lighting zone(s)served by daylight responsive E-1 <br /> controls; <br /> Identify sidelight and toplight daylight zones that are not <br /> provided with daylight sensing controls and the exception(s)that <br /> Yes C405.2.4 Daylight responsive apply; <br /> controls Indicate on plans the lighting load reduction method- <br /> continuous dimming,or stepped dimming that provides at least E-1 <br /> two even steps between 0%-100%of rated ower; <br /> Indicate that daylight sensing controls are configured to <br /> completely shut off all controlled lights in the lighting zone <br /> Additional controls- Identify spaces and lighting fixtures on plans that require <br /> NA C405.2.5 Specific application <br /> li htin controls specific application lighting controls per this section <br /> Indicate on plans that display and accent lighting,and display <br /> C405.2.5- Display and accent case lighting are controlled independently from both general <br /> NA <br /> Items 1&2 lighting area lighting and other lighting applications within the same <br /> space; <br /> Indicate manual and automatic lighting control method <br /> � CF <br />
The URL can be used to link to this page
Your browser does not support the video tag.