Laserfiche WebLink
2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised August 2016 <br /> Project Title: HearUSA-Edmonds,WA Date 2/14/2017 <br /> The following information is necessary to check a permit application for compliance with the lighting,motor,and electrical requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> Applicability Location in Building epa men <br /> (yes,no,na) Code Section Component Compliance information required in permit documents Documents Notes <br /> LIGHTING CONTROLS <br /> Lighting controls, For all lighting fixtures,indicate lighting control method s , <br /> Yes C405.2 I s <br /> general for spaces and lighting zone(s)served,or exception tak <br /> Luminaire level Indicate on plans all fixtures provided with LLLC in lieu o <br /> Yes C405.2 lighting controls C405.2 lighting controls;provide description of control E-1 <br /> LLLC ca abilities and performance parametersPPR <br /> For permanently installed lighting fixtures in dwelling unit <br /> NA C405.1 Lighting in dwelling indicate lighting control method on plans for spaces and �` RET <br /> rT <br /> units lighting zone(s)served,or demonstrate compliance with highC I 1 OF EV R r <br /> efficacy exception darmit c ('� <br /> C405.2.3 Indicate on plans the method of manual lighting control(wheth r <br /> C405.2.1.1 combined with occupancy sensor,automatic light reduction, <br /> Yes C405.2.2.2 Manual controls daylight responsive or specific application controls),location of E-1 <br /> C405.2.4 manual control device and area or specifice application it <br /> C405.2.5 serves <br /> C405.2.2.1 Manual interior Indicate on plans which method of manual 50%lighting load <br /> Yes C405.2.2.2 lighting controls reduction is provided,or whether lighting load is reduced via E-1 <br /> C405.2.3 occupancy sensors or daylight responsive controls <br /> Indicate on plans the method of automatic shut-off control <br /> during unoccupied periods(occupancy sensor or time switch) E-1 <br /> Yes C405.2.2 Method of automatic for all lighting zones; <br /> shut-off control Indicate locations where automatic shutoff is provided by other <br /> methods(occupancy sensor or digital timer switch)or which E-1 <br /> time switch control exception applies <br /> Indicate on plans the spaces served by occupancy sensors; E-1 <br /> Yes C405.2.1 Occupancy sensor Indicate whether occupancy sensor controls are configured to <br /> C405.2.1.1 controls be manual-on,automatic 50%-on,or serve a space eligible for <br /> automatic 100%-on per exception <br /> Occupancy sensor Indicate aisleways and open areas in warehouse spaces <br /> NA C405.2.1.2 controls- provided with occupancy sensor controls that reduce lighting <br /> warehouses power by 50% <br /> NA C405.2.6 Digital timer switch Indicate required digital timer switch control function when <br /> control is used <br /> C405.2.2.1 Automatic time Indicate locations of override switches on plans and the lighting <br /> switch controls zones served,include areas .ft. <br /> Indicate primary and secondary sidelight daylight zone areas on E-1 <br /> plans,include sq.ft.; <br /> C405.2.4.2 Daylight zones- Indicate toplight daylight zone areas on plans,include s .ft.; <br /> Yes For small vertical fenestration assemblies(rough opening less <br /> C405.2.4.3 Sidelight and toplight than 10 percent of primary daylight zone)where daylight <br /> responsive controls are not required,provide fenestration area <br /> to daylight zone calculation(s) <br /> Indicate on plans lighting zone(s)served by daylight responsive E-1 <br /> controls; <br /> Identify sidelight and toplight daylight zones that are not <br /> provided with daylight sensing controls and the exception(s)that <br /> Yes C405.2.4 Daylight responsive apply; <br /> controls Indicate on plans the lighting load reduction method- <br /> continuous dimming,or stepped dimming that provides at least E-1 <br /> two even steps between 0%-100%of rated ower; <br /> Indicate that daylight sensing controls are configured to <br /> completely shut off all controlled lights in the lighting zone <br /> Additional controls- Identify spaces and lighting fixtures on plans that require <br /> NA C405.2.5 Specific application <br /> li htin controls specific application lighting controls per this section <br /> Indicate on plans that display and accent lighting,and display <br /> C405.2.5- Display and accent case lighting are controlled independently from both general <br /> NA <br /> Items 1&2 lighting area lighting and other lighting applications within the same <br /> space; <br /> Indicate manual and automatic lighting control method <br /> � CF <br />