Laserfiche WebLink
u <br /> A =PROVIDENCE REGIONAL <br /> $� <br /> MEDICAL CENTER EVERETT ® 2 <br /> PACIFIC CAMPUS - COMPRESSOR REPLACEMENT <br /> 916 PACIFIC AVE , EVERETT, WASHINGTON, 98201 <br /> g i l7, <br /> Q <br /> H <br /> N <br /> SYMBOLS AND ABBREVIATIONS <br /> ELECTRICAL RISER EQUIPMENT GENERAL NOTES <br /> AVAILABLE FAULT CURRENT IDENTIFICATION ® ®E EQUIPMENT CONNECTION,E=EMERGENCY POWER 1. COMPLY W TH THE NATIONAL ELECTRICAL CODE AS ADOPTED AND AMENDED BY THE LOCAL <br /> 7> W SURGE PROTECTIVE DEVICE AUTHORITY HAVING JJRISDICTION. <br /> AUTOMATIC TRANSFER SWITCH 2. PROJECT SCOPE IS TO REPLACE EXISTING 10 HP COMPRESSOR WITH NEWVFD AND COMPRESSOR. <br /> Q TRANSFORMER,t30KVA,NOT TO SCALE THIS REPRESENTS A ZERO LOAD ADDED TO THE ELECTRICAL DISTRIBUTION SYSTEM. <br /> SACE BUS SPACE <br /> ® TRANSFORMER,30KYA OR GREATER,DRAWN TO SCALE <br /> n CIRCUIT BREAKER <br /> 1 GROUND <br /> • SPLICE <br /> CIRCUITS ABBREVIATIONS z <br /> r"y'" rN TRANSFORMER <br /> (0) TRANSFORMER,CURRENT -"h- RACEWAY CONCEALED IN CEILING OR WALL HASH MARKS AF AMP FUSE w <br /> INDICATE NUMBER OF WIRES./12 AWG WIRE UNLESS OTHERWISE AIC AMPERE INTERRUPTING CAPACITY <br /> NOTED.EXPOSED RACEWAY IS ALLOWED ONLY WHERE NOTED. <br /> EG <br /> ENGINE-GENERATOR NOTED. <br /> AMP SNITCH <br /> WOMEN'S AND -+— HOT(SHORT HASH MARK) A AMPS o <br /> O KEY INTERLOCK ATS AUTOMATIC TRANSFER SWITCH Y <br /> { CHILDREN'Ssl METER �- NEUTRAL(LONG HASH MARK) C CONDUIT w 9 Z <br /> —+- piQUND WARE(JOGGED HASH MARK) CB CIRCUIT BREAKER U F� <br /> F� RELAY EXISTING RACEWAY(IF HASH MARKS ARE SOWN,PULL NEW EQUIP EQUIPMENT <br /> J VI O <br /> MAIN HOSPITAL L1-1 RELAY,GFI .--- CONDUCTORS) G.GNO GROUND z Of N <br /> RACEWAY BELOW S.AS OR UNDERGROUND HP HORSEPOWER 3 <br /> ® SURGE PROTECTIVE DEVICE x H S 00¢ n <br /> RACEWAY UP <br /> NEC NATIONAL EIFCTRICAL CODE Q , (n U0 O O <br /> —• <br /> P POLES <br /> —• RACEWAY DOWN PNL PANEL,PANELBOARD <br /> RACEWAY STUB-OUT WITH BUSTING RECEPT RECEPTACLE <br /> SWBD SWITCHBOARD <br /> PANELBOARDS —� CIRCUIT CONTINUATION TYP TYPICAL <br /> AREA!1F UNK UNKNOWN <br /> i <br /> 208V SYSTEM PANELBOARD —� HOME RUN TO PANEL OR LOCATION NOTED V VOLT OR VOICE (n <br /> JUNCTION BOX 05 A80V SYSTEM PANELBOARD OO W WK,VARIABLE FREQUENCY <br /> WATi,ORW LALPHONE _O <br /> V <br /> ® PULL eox <br /> XFNR TRANSFORMER f- <br /> 0 PHASE Q <br /> iE <br /> CONTROLS WORK DEFINITION DRAWING LIST m z <br /> FUSED DISCONNECT SNITCH(FUSE RATING INDICATED) ® FLAG NOTE EO.00 ELECTRICAL SYMBOLS,ABBREVIATIONS AND DRAWING LIST m <br /> Lij <br /> OVERALL KEY PLAN E0.01 ELECTRICAL SPECIFICATIONS Q w <br /> SCALE:NONE a D Qt REVISION IDENTIFICATION d <br /> E1.00 BOILER ROOM ELECTRICAL PLAN U <br /> QPROJECT NORTH REFERENCE E2.00 NORTH WING ONE-UNE DIAGRAM O Q <br /> SS22 m ~ Ud <br /> S — NEW WORK W 0 <br /> W <br /> 1 EXISTING (n <br /> FUTURE _jz U O <br /> Q U) <br /> .... REMOVE EXISTING ELECTRICAL EQUIPMENT 0 � d' Lu <br /> 1 LL1 <br /> U U 0- <br /> w W W <br /> � Lz 0 � o <br /> W Q o <br /> r � cf � � SHEET: <br /> E0.00 <br />