ICC A117.1-2009 Chapter 6. Plumbing Elements and Facilities <br /> 604.3 Clearance. has been installed in walls and located so as to <br /> permit the installation of grab bars complying <br /> Other fixtures not allowed with Section 604.5. <br /> within this area 2. In detention or correction facilities, grab bars <br /> are not required to be installed in housing or <br /> — — — — — i holding cells or rooms that are specially <br /> - - r designed without protrusions for purposes of <br /> i `J suicide prevenlien- — <br /> G \ <br /> LO <br /> )430-48 <br /> a' <br /> 60 in is <br /> 15 <br /> FIG.604.3 <br /> SIZE OF CLEARANCE FOR WATER CLOSET <br /> t1 <br /> 604.3.1 Clearance width. Clearance around a water �ote: For children's dimensions see Fig.6:11.4 <br /> closet shall be 60 inches (1525 mm) minimum in ,N FIG.604.4 <br /> width, measured perpendicular from the sidewall. '-, ,,,WATER CLOSE HEIGHT <br /> 604.3.2 Clearance Depth. Clearance around the <br /> water closet shall be 56 inches (1420 mm) mini- <br /> mum in depth, measured perpendicular from the <br /> rear wall. 604.5.1 Fixed Side Wall Grab Bars. Fixed side-wall <br /> 604.3.3 Clearance Overlap. The required clear- grab bars shall be 42 inches (1065 mm) minimum in <br /> ance around the water closet shall be permitted to length, located 12 inches (305 mm) maximum from <br /> overlap the water closet, associated grab bars, the rear wall and extending 54 inches (1370 mm) <br /> minimum from the rear wall. In addition, a vertical <br /> paper dispensers, sanitary napkin receptacles, <br /> coat hooks, shelves, accessible routes, clear floor grab bar 18 inches(455 mm) minimum in length shall <br /> space at other fixtures and the turning space. No be mounted with the bottom of the bar located 39 <br /> other fixtures or obstructions shall be within the inches (990 mm) minimum and 41 inches (1040 mm) <br /> required water closet clearance. <br /> 604.4 Height. The height of water closet seats shall be 39-4 <br /> 17 inches (430 mm) minimum and 19 inches (485 mm) 990-1(40 <br /> maximum above the floor, measured to the top of the <br /> 54 min LO <br /> seat. Seats shall not be sprung to return to a lifted posi- 12 max / 370 i 0 <br /> tion. 305 <br /> EXCEPTION: A water closet in a toilet room for a sin- 42 min <br /> gle occupant, accessed only through a private office 1065 <br /> and not for common use or public use, shall not be <br /> required to comply with Section 604.4. <br /> 604.5 Grab Bars. Grab bars for water closets shall Lection C) <br /> comply with Section 609 and shall be provided in accor- Modance with Sections 604.5.1 and 604.5.2. Grab bars I oshall be provided on the rear wall and on the side wallco � 0) <br /> closest to the water closet. co <br /> EXCEPTIONS: . 1 -71 <br /> 1. Grab bars are not required to be installed in a <br /> Note: For children's dimensions see Fig.609.4.2 <br /> toilet room for a single occupant, accessed <br /> only through a private office and not for com- FIG.604.5.1 <br /> mon use or public use, provided reinforcement SIDE WALL GRAB BAR FOR WATER CLOSET <br /> d� <br />