2720 RUCKER AVE 2017-10-25
>
Address Records
>
RUCKER AVE
>
2720
>
2720 RUCKER AVE 2017-10-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2017 9:08:52 AM
Creation date
10/25/2017 9:08:50 AM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
2720
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HEATING & AIR CONDITIONING <br /> Product Specifications <br /> OUTDOOR UNIT(a)(b) 4A6H4048G1000A (a) Certified in accordance with the Air-Source Unitary Air-conditioner <br /> POWER CONNS,—V/PH/HZ W 208/230/1/60 Equipment certification program,which is based on AHRI standard <br /> 210/240, <br /> MIN.BRCH.CIR.AMPACITY 25 (b) Rated in accordance with AHRI standard 270. <br /> BR.CIR.PROT.RTG.—MAX,(AMPS) 45 (I) Calculated in accordance with Natl.Elec.Codes.Use only HACK <br /> circuit breakers or fuses. <br /> COMPRESSOR DURATIONI"-SCROLL (d) This value shown for compressor RLA on the unit nameplate and on <br /> NO.USED—NO.STAGES 1—1 this specification sheet Is used to compute minimum branch circuit <br /> ampaclty and max.fuse size.The value shown is the branch Circuit <br /> VOLTS/PH/HZ 208/230/1/60 selection current. <br /> R.L.AMPS(d)—L.R.AMPS19.6-130 No means no start components.Yes means quick start kit <br /> components.PTC means positive temperature coefficient starter. <br /> FACTORY INSTALLED Optional kit shown, <br /> START COMPONENTS(`) NO(Uses BAYKSKT263) M Standard Air—Dry Coil—Outdoor <br /> (fl) This value approximate.For more precise value see unit nameplate, <br /> INSULATION/SOUND BLANKET NO (h) Reference the outdoor unit ship-with literature for refrigerant piping <br /> COMPRESSOR HEAT NO length and lift guidelines.Reference the refrigerant piping software <br /> pub#32-3312-xx or refrigerant piping application guide SS- <br /> OUTDOOR FAN PROPELLER APG006-xx for long line sets or specialty applications(xx denotes <br /> latest revision). <br /> DIA,(IN.)—N0,USED 27.5—1 <br /> (') Trane outdoor condensing units are factory charged with the system <br /> TYPE DRIVE—NO.SPEEDS DIRECT—1 charge required for the outdoor condensing unit and 15 feet of tested <br /> CFM @ 0.0 IN.W.G.(f> connecting lines,If connecting line length exceeds 15 feet,then final <br /> 4230 refrigerant charge adjustment is necessary.Each additional foot over <br /> NO.MOTORS—HP 1-1/5 15 feet requires 0.6 ozs of refrigerant.See the Installer`s Guide for <br /> MOTOR SPEED R.P.M, 850 full charging Instructions, <br /> VOLTS/PH/HZ 208/230/1/60 <br /> F.L.AMPS .93 <br /> OUTDOOR COIL—TYPE SPINE FIN`" <br /> ROWS—F.P.I. 1-24 <br /> FACE AREA(SQ.FT.) 22 <br /> TUBE SIZE(IN.) 3/8 <br /> REFRIGERANT CONTROL EXPANSION VALVE <br /> REFRIGERANT <br /> LBS.—R-410A(O.D,UNIT)(9) 8 LBS.,2 OZ <br /> FACTORY SUPPLIED YES <br /> LINE SIZE—IN.O.O.GAS(h)0) 7/8 <br /> LINE SIZE—IN.O.D.LIQ. 3/8 <br /> CHARGING SPECIFICATIONS <br /> SUBCOOLING 10°F <br /> DIMENSIONS H X W X D <br /> CRATED(IN.) 38.4 x 38,7 x 35.1 <br /> WEIGHT <br /> SHIPPING(LBS.) 300 <br /> NET(LBS.) 266 <br /> 4A6H4048G-SF-1 C-EN <br />
The URL can be used to link to this page
Your browser does not support the video tag.