Laserfiche WebLink
GENERAL YES NO <br /> Bathroom doors are easily and quicklyopenable from the outside when locked M ❑ <br /> Carbon Monoxide alarms are installed as required!n R315 on each l evel of the home. 13 <br /> Smoke a I arms are installed on all I evels of the dwel I ing,in each residents leepi ng room,outside each separate <br /> sI eepi ng area in the i mmediate vi cinity of sleeping rooms(11314). 13 <br /> Smoke and Carbon Monoxide alarms are installed ins uchamanner sothat the audiblewarningmaybe heard inall <br /> parts of the dwel I ing upon activation of a single device. IN. 13 <br /> Access road and water supply meet l oval fi rej udsdiction al requirements. <br /> R325.4 Operable parts of door handles,pulls,latches,locks and other devices installed in AFH shall be operable with one hand <br /> and shall not require tight grasping,pinching or twisting of the wrist(lever-type). ❑ <br /> Pocket doors shall have graspable ha rdwa re available when in the closed or open position. <br /> IMV <br /> R311.8 Ramps YES NO <br /> Inside Ramp N/A ❑ ❑ <br /> R311.8.1 Maximum Slope one unitvertical in twelve units horizontal(8.3%slope).(Exception R311.8.1 Not allowed in AFH) <br /> R311.8.2 Landing Requirements:min.3X3 foot landingattop/bottom,where doorsopen onto ramps,and where rampchanges <br /> directions. ❑ ❑ <br /> R325.9.1 Handrails required on both sides of ramp in accordancewith R311.83.1—R311.8.3.3. ❑ ❑ <br /> Outside Ramp I N/Alc <br /> YES NO <br /> R311.8.1 Maximum Slope one unit vertical in twelve units horizontal(8.3%slope).(Exception R311.8.1 Not allowed in AFH) <br /> R311.8.2 Landing Requirements:min.3X3 foot landing attop/bottom,where doors open onto ramps,and where rampchanges 13directions. <br /> 13 <br /> R325.9.1 Handrails required on both sides of ramp in accordance with R311.8.3.1—R311.8.3.3. ❑ 0 <br /> Guards below are depicted vertically as an example only.All Ramps must have Guards ❑ ❑ <br /> Handrail both sides <br /> Less than 4" 34"-38" <br /> Guard <br /> 36"min <br /> 3'x3'min <br /> 3'x3'min landing <br /> landing <br /> 3One unit vertical in twelve units horizontal 3' <br /> minimum is an 8.3%slope all along surface of the ramp. minimum <br /> R311.2 Means of Egress YES NO <br /> R311.2 Door must be side-hinged with min.width of 32 inches between face of door and stop.Height not less than 78 inches. ❑ <br /> R325.4 Operable parts of door handles,pulls,latches,locks and other devices installed in AFH shall be operable with one hand <br /> and shall not require tight grasping,pinching or twisting of the wrist(lever-type). ❑ <br /> R325.4 Required exit door hardware shall unlock insideand outside mechanisms when exitingthe building allowing re-entry <br /> without use of key,tool orspecial knowledge. <br /> R311.7Stairways I N/A YES NO <br /> R311.7.5.1 Riser Height:Max riser height shall be 7%inches(8 inches in structures built priorto July 1,2004) ❑ ❑ <br /> R311.7.5.2 Tread Depth:Min.tread depth shall be in 10 inches(9 inches in structures built priorto July 1,2004) <br /> R325.10.1 Handrails for Treads and Risers shall be installed on both sides of treads and risers numbering from one riser to m ultiple E3risers.Ha ndra ils shall be installed in accordance with R311.7.8.1—R311.7.8.4 <br /> Effective:2013 July 01 <br /> Updated:2017 February rr <br /> 1� f <br />