My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6301 36TH AVE W BYRAM HEALTHCARE 2017-10-26
>
Address Records
>
36TH AVE W
>
6301
>
BYRAM HEALTHCARE
>
6301 36TH AVE W BYRAM HEALTHCARE 2017-10-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/26/2017 9:26:26 AM
Creation date
10/26/2017 9:26:16 AM
Metadata
Fields
Template:
Address Document
Street Name
36TH AVE W
Street Number
6301
Tenant Name
BYRAM HEALTHCARE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
52
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Interior • • i • • • <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised August 2016 <br /> Project Title: Byram TI Date 1/1/2016 <br /> Calculation 0 0 Addition- 0 Addition For Building Department Use <br /> NOTE stand alone +existing <br /> Area O Spaces where< 50%of O Spaces where>_50%of 0 <br /> luminaires are replaced luminaires are replaced <br /> LPA Standard 0 Additional Efficiency Package Option 0 <br /> Calculation C406.3 Reduced Interior Lighting Power <br /> To comply with C406.3.the Proposed LPD shall be 25%lower than the Target LPA. <br /> Type Refer to C406.3 for additional requirements. <br /> Maximum Allowed Lighting Wattage"ITE' <br /> Location(plan#, Height Gross Interior Allowed Watts Allowed <br /> room#) Space Type 2 Area in ft2 Watts per ft2 (watts/ft2 x area) <br /> Open Office Office:Open plan 288 0.780 225 <br /> Office Office: Enclosed 119 0.890 106 <br /> Break Lounge/breakroom:all other 163 0.580 95 <br /> Toilets Restroom:all other 106 0.780 83 <br /> Warehouse Warehouse:Smaller,hand carried items 24505 0.760 18624 <br /> Total Area 25181 <br /> Retail Display Allowance from LTG-INT-DISPLAY <br /> Lobby Art/Exhibit Display Allowance from LTG-INT-DISPLAY"OTE 8� Allowed Watts 19132 <br /> Proposed Lighting Wattage""' <br /> Location(plan#, Number of Watts/ Watts <br /> room#) Fixture Description"OTE 4,5,6 Fixtures Fixture"OTE 7 Proposed <br /> Offices 2x4 LED 7 47 329 <br /> Toilets 1x4 LED 2 23 46 <br /> Proposed Retail Display Lighting from LTG-INT-DISPLAY <br /> Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts 375 <br /> Interior Lighting Power Allowance COMPLIES <br /> Note 1-List all unique space types per Table C405.4.2(2)that occur in the project scope.Select space type category per from drop down menu. <br /> Note 2-Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2),Footnotes d thru f. <br /> Note 3-List all proposed lighting fixtures including exempt lighting equipment and existing-to-remain fixtures. <br /> Note 4-For proposed Fixture Description,indicate fixture type,lamp type(e.g. T-8),number of lamps in the fixture,and ballast type(if included).For <br /> track lighting,list the length of the track(in feet)in addition to the fixture,lamp,and ballast information. <br /> Note 5-For lighting equipment eligible for exemption per C405.4.1,note exception number and leave Watts/Fixture blank. <br /> Note 6-Existing-to-remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures. Identify as existing <br /> in fixture description. <br /> Note 7-For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source.For <br /> luminaires with screw-in lamps,enter the manufacturer's listed maximum input wattage of the fixture(not the lamp wattage).For low voltage <br /> lighting,enter the wattage of the transformer.For line voltage track/busway systems,enter the larger of the attached luminaire wattage or 50 <br /> watts/lineal foot,or enter the wattage limit of permanent current limiting device. <br /> Note 8-Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage. <br /> Note 9-Calculation Area Details: <br /> a.Lighting fixtures in a building addition may comply as a stand alone project,or they may be combined with the overall existing building <br /> lighting systems to demonstrate compliance.Refer to C502.1. <br /> b.For alterations and building additions,provide Space Types and gross interior areas in the Maximum Allowed Lighting Wattage table.If a <br /> building addition will comply as combined with the overall existing building lighting systems,include all applicable existing Space Types <br /> and gross interior areas. <br /> c.If less than 50%of existing lighting fixtures will be replaced,provide total existing lighting wattage(prior to alteration)in the space provided <br />
The URL can be used to link to this page
Your browser does not support the video tag.