[Component Perform 6-.e Path, pg. 2 ENV-Uk, <br /> 2015 WSEC Compliance Forms for Commercial Buildings including R2,R3,&R4 over 3 stories and all R1 Revised Jun 2016 <br /> Project Title: JBC Product Management TI Date 01/17/2017 <br /> Fenestration Area as%gross above-grade wall area Max.Target: 30.0% For Building Department Use <br /> Skylight Area as%gross roof area Max.Target: 3.0% <br /> Building Component Proposed UA Target UA <br /> Ins. R Plan/Detail# F-factor Source&Table#8 F-factor x Perimeter =UA(U x A) F-factor x Perimeter= UA(U x A) <br /> R= Sheet A2.1 Table A106.1 0.730 101 73.7 0.540 101 54.5 <br /> R= Slab-On-Grade F-0.54 <br /> C <br /> c D R- <br /> Q -o R= 0.550 <br /> �0 a) <br /> C R= Heated Slab-On-Grade F-0.55 <br /> = R= <br /> Schedule ID U-factor Source9'10 U-factor x Area(A) =UA(U x A U-factor x Area(A)= UA(U x A) <br /> m 111B Al 07.1(1) 0.370 21 7.8 0.37 21 7.8 <br /> o, I ! Opaque Swing Doors U-0.37 <br /> c <br /> 3 <br /> U) <br /> 0 <br /> p 0.34 <br /> Q) Opaque rollup&sliding U-0.34 <br /> O <br /> m <br /> 0.30 <br /> Non-Metal Frame U-0.30 <br /> c <br /> 0 <br /> Z <br /> Building Shell Permit 0.38 1 403 153.1 0.38 403 153.1 <br /> Metal Frame, Fixed U-0.38 <br /> o - � <br /> � m <br /> Z') 2 <br /> Q) <br /> c <br /> 0 0_ 0.40 <br /> LL o <br /> Metal Frame,Operable U-0.40 <br /> U � I <br /> J <br /> °; Building Shell Permit 0.60 21 12.6 0.60 21 12.6 <br /> Metal Entrance Door U-0.60 <br /> c <br /> a� <br /> N 0.50 <br /> s a All types U-0.50 <br /> m F <br /> V) Q <br /> Area UA Area UA <br /> Page 2 Subtotal 546 247 546 228 <br /> TO COMPLY-The Proposed Total UA shall not Page 1 Subtotal 4953 1 187 4953 218 <br /> exceed the Target Total UA. Project Total 5499 1 434 5499 1 446 <br /> Component Performance Compliance (UA) UA COMPLIES <br /> Note 1-If vertical fenestration or skylight area exceeds maximum allowed per C402.4.1, then Target Area Adjustment of all applicable envelope <br /> elements will be calculated automatically by the compliance form. Refer to Target Area Adjustments worksheet for this calculation. <br /> Note 2-Opaque assembly U-factors shall come from Appendix A or calculated per approved method as specified in C402.1.5.1. <br /> Note 3-Proposed CMU mass wall in non-Group R that meet Table C402.1.4 Footnote D requirements can enter the target U-value of 0.014 <br /> Note 4-For semi-heated spaces utilizing the wall insulation exception,enter Target Wall U-factors under Proposed Wall LI-factors so exterior <br /> walls are neutral to the calculation. <br /> Note 5-Mass transfer slab edges must be covered with an assembly having an overal U-factor of 0.2. <br /> Note 6-Demising walls,doors,and vertical fenestration separating spaces with different degrees of space conditioning(unconditioned,semi-heated, <br /> fully conditioned)shall be included only on the ENV-UA form for the space with the greatest degree of space conditioning. <br /> Note 7-List Group R above grade mass walls here. List all other mass walls,Commercial and Group R,in the Opaque Walls-Above Grade section. <br /> Note 8 Slab-on-grade F-Factors shall come from Appendix A or calculated per approved method as specified in C402.1.5.1. <br /> Note 9 -Opaque door U-factors shall come from Appendix A or calculated per approved method as specified in C402.1.5.1.A door is defined as <br /> opaque if less than 50%of the door area has glazing. <br /> Note 10-Fenestration assembly U-Factors shall be the manufacturer's NFRC product rating, which includes the glazing and frame,or shall be <br /> the default value per Section C303.1.3. // <br />