9600 HOLLY DR CHALLENGER ELEMENTARY SCHOOL 2017-12-20
>
Address Records
>
HOLLY DR
>
9600
>
CHALLENGER ELEMENTARY SCHOOL
>
9600 HOLLY DR CHALLENGER ELEMENTARY SCHOOL 2017-12-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2017 7:50:57 AM
Creation date
11/17/2017 12:05:46 PM
Metadata
Fields
Template:
Address Document
Street Name
HOLLY DR
Street Number
9600
Tenant Name
CHALLENGER ELEMENTARY SCHOOL
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
50
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
aSimplEx 4IOO42) Fire Control Panels <br /> UL, ULC, CSFM Listed; FM Approved; Addressable Fire Detection and Control <br /> MEA (NYC) Acceptance* Basic Panel Modules arid Accessories <br /> Features <br /> Master Controller(top) bay: ' <br /> • 32-Bit Master Controller with color-coded operator <br /> interface including raised switches for high confidence _ <br /> feedback <br /> • Dual configuration program CPU,convenient service port r i . r <br /> access,and capacity for up to 2500 addressable pointsr. ---- -r,- <br /> • CPU assembly includes 2 GB dedicated compact flash <br /> memory for on-site system programming and _ <br /> information storage slog '� <br /> • System power supply(SPS)and charger(9 A total)with .. _ a l l i - . <br /> on-board:NACs,IDNet addressable device interface, - ' <br /> programmable auxiliary output and alarm relay --------- <br /> • Available with InfoAlarm Command Center expanded .....iiiii,� -m. <br /> content user interface(see data sheet S4100-0045) <br /> Upgrade kits are available for existing control panels 4100ES Cabinets are Available with <br /> • One,Two or Three Bays <br /> Standard addressable interfaces include: <br /> • IDNet addressable device interface with 250 points that Software Feature Summary <br /> support TrueAlarm analog sensing and operate with CPU provides dual configuration programs: <br /> either shielded or unshielded twisted pair wiring <br /> • Two programs allow for optimal system protection and <br /> • Remote annunciator module support via RUI(remote <br /> unit interface)communications port commissioning efficiency with one active program and <br /> one reserve <br /> Optional modules include: • Downtime is reduced because the system stays running <br /> • Building Network Interface Module(BNIC)for Ethernet during download <br /> connectivity options(see data sheet S4100-0061) <br /> PC based programmer features: <br /> • Electrically isolated output IDNet 2(two loop)and • Convenient front panel accessed Ethernet port for quick <br /> IDNet 2+2(four loop)modules with short circuit isolation <br /> output loops allowing use with either shielded or and easy download of site-specific programming <br /> unshielded,twisted or untwisted single pair wiring • Modifications can be uploaded as well as downloaded <br /> • Fire Alarm Network Interfaces,DACTs,city connections, for greater service flexibility <br /> and up to five(5)RS-232 ports for printers and terminals • AND,firmware enhancements are made via software <br /> • IP communicator compatibility downloads to the on-board flash memory <br /> • MAPNET II addressable device modules and Introduction <br /> MAPNET II quad isolator modules <br /> • Alarm relays,auxiliary relays,additional power 4100ES Series Fire Detection and Control Panels <br /> supplies,IDC modules,NAC expansion modules provide extensive installation,operator,and service features <br /> • Service modems,VESDA Air Aspiration Systems with point and module capacities suitable for a wide range of <br /> interface,ASHRAE BACnet Interface,TCP/IP Bridges system applications.An on-board Ethernet port provides fast <br /> • LED/switch modules and panel mount printers external system communications to expedite installation and <br /> • Emergency communications systems(ECS)equipment; service activity.Dedicated compact flash memory archiving <br /> 8 channel digital audio or 2 channel analog audio provides secure on-site system information storage of <br /> electronic job configuration files to meet NFPA 72(National <br /> • Battery brackets for seismic area protection(see page 2) Fire Alarm and Signaling Code)requirements. <br /> Compatible with Simplex® remotely located Modular design.A wide variety of functional modules <br /> 4009 IDNet NAC Extenders, up to ten per IDNet <br /> SLC are available to meet specific system requirements. <br /> Selections allow panels to be configured for either <br /> 4100ES and upgrade kits are UL Listed to: Stand-Alone or Networked fire control operation.InfoAlarm <br /> • UL 864,Fire Detection and Control(UOJZ),and Smoke Command Center options provide convenient expanded <br /> Control Service(UUKL) display content(detailed on data sheet S4100-0045). <br /> • UL 2017,Process Management Equipment(QVAX) <br /> • UL 1076,Proprietary Alarm Units-Burglar(APOU) * See pages 5 and 6 for product that is UL or ULC listed and additional listing information. <br /> This product has been listed by the California State Fire Marshal(CSFM)pursuant to <br /> • UL 1730,Smoke Detector Monitor(UULH) Section 13144.1 of the Caldomia Health and Safety Code.See CSFM Listing <br /> • UL 2572,Mass Notification Systems(PGWM));refer 7165.0026:251(4100ES)for allowable values and/or conditions concerning material <br /> presented in this document.Accepted for use—City of New York Department of Buildings— <br /> to data sheet S4100-0034 for audio equipment MEA35-93E.Additional listings may be applicable;contact your local Simplex product <br /> • ULC S527,Control Units for Fire Alarm Systems supplier for the latest status.Listings and approvals under Simplex Time Recorder Co.are <br /> the property of Tyco Fire Protection Products. <br /> S4100-0031-30 12/2014 ( 3 <br /> S 5 <br />