Laserfiche WebLink
(( CHAPTER 6 <br /> • <br /> MECHANICAL AND ELECTRICAL REQUIREMENTS <br /> SECTION 601 602.4 Occupiable work spaces. Indoor occupiable work <br /> GENERAL spaces shall be supplied with heat during the period from <br /> 601.1 Scope. The provisions of this chapter shall govern the [DATE]to[DATE]to maintain a minimum temperature of 65°F <br /> minimum mechanical and electrical facilities and equipment (18°C)during the period the spaces are occupied. <br /> to be provided. Exceptions: <br /> 601.2 Responsibility. The owner of the structure shall pro- 1. Processing,storage and operation areas that require <br /> vide and maintain mechanical and electrical facilities and cooling or special temperature conditions. <br /> equipment in compliance with these requirements. A person 2. Areas in which persons are primarily engaged in <br /> shall not occupy as owner-occupant or permit another person vigorous physical activities. <br /> to occupy any premises that does not comply with the <br /> requirements of this chapter. 602.5 Room temperature measurement.The required room <br /> temperatures shall be measured 3 feet (914 mm) above the <br /> floor near the center of the room and 2 feet(610 mm)inward <br /> SECTION 602 from the center of each exterior wall. <br /> HEATING FACILITIES <br /> 602.1 Facilities required. Heating facilities shall be pro- SECTION 603 <br /> vided in structures as required by this section. MECHANICAL EQUIPMENT <br /> 602.2 Residential occupancies.Dwellings shall be provided 603.1 Mechanical appliances. Mechanical appliances, fire- <br /> with heating facilities capable of maintaining a room temper places, solid fuel-burning appliances, cooking appliances and <br /> ature of 68°F (20°C) in all habitable rooms, bathrooms and water heating appliances shall be properly installed and main- <br /> toilet rooms based on the winter outdoor design temperature tained in a safe working condition, and shall be capable of <br /> to , for the locality indicated in Appendix D of the International performing the intended function. <br /> Plumbing Code. Cooking appliances shall not be used, nor <br /> shall portable unvented fuel-burning space heaters be used,as 603.2 Removal of combustion products. Fuel-burning <br /> a means to provide required heating. equipment and appliances shall be connected to an approved <br /> Exception: In areas where the average monthly tempera chimney or vent. <br /> ture is above 30°F(-1°C),a minimum temperature of 65°F Exception: Fuel-burning equipment and appliances that <br /> (18°C)shall be maintained. are labeled for unvented operation. <br /> 6023 Heat supply.Every owner and operator of any build- 603.3 Clearances.Required clearances to combustible mate- <br /> ing who rents, leases or lets one or more dwelling units or rials shall be maintained. <br /> sleeping units on terms, either expressed or implied, to fur- 603.4 Safety controls. Safety controls for fuel-burning <br /> nish heat to the occupants thereof shall supply heat during the equipment shall be maintained in effective operation. <br /> period from[DATE]to[DATE]to maintain a minimum temper 603.5 Combustion air.A supply of air for complete combus- <br /> ature of 68°F (20°C) in all habitable rooms, bathrooms and tion of the fuel and for ventilation of the space containing the <br /> toilet rooms. fuel-burning equipment shall be provided for the fuel-burning <br /> Exceptions: equipment. <br /> 1. When the outdoor temperature is below the winter 603.6 Energy conservation devices. Devices intended to <br /> outdoor design temperature for the locality,mainte- reduce fuel consumption by attachment to a fuel-burning <br /> nance of the minimum room temperature shall not appliance,to the fuel supply line thereto,or to the vent outlet <br /> be required provided that the heating system is or vent piping therefrom,shall not be installed unless labeled <br /> operating at its full design capacity.The winter out- for such purpose and the installation is specifically approved. <br /> door design temperature for the locality shall be as <br /> indicated in Appendix D of the International <br /> Plumbing Code. SECTION 604 <br /> 2. In areas where the average monthly temperature is ELECTRICAL FACILITIES <br /> above 30°F(-1°C),a minimum temperature of 65°F 604.1 Facilities required. Every occupied building shall be <br /> (18°C)shall be maintained. provided with an electrical system in compliance with the <br /> requirements of this section and Section 605. <br /> 2015 INTERNATIONAL PROPERTY MAINTENANCE CODE® <br /> /72, <br />